152010-Thumbnail Image.png
Description
Micro Electro Mechanical Systems (MEMS) is one of the fastest growing field in silicon industry. Low cost production is key for any company to improve their market share. MEMS testing is challenging since input to test a MEMS device require physical stimulus like acceleration, pressure etc. Also, MEMS device vary

Micro Electro Mechanical Systems (MEMS) is one of the fastest growing field in silicon industry. Low cost production is key for any company to improve their market share. MEMS testing is challenging since input to test a MEMS device require physical stimulus like acceleration, pressure etc. Also, MEMS device vary with process and requires calibration to make them reliable. This increases test cost and testing time. This challenge can be overcome by combining electrical stimulus based testing along with statistical analysis on MEMS response for electrical stimulus and also limited physical stimulus response data. This thesis proposes electrical stimulus based built in self test(BIST) which can be used to get MEMS data and later this data can be used for statistical analysis. A capacitive MEMS accelerometer is considered to test this BIST approach. This BIST circuit overhead is less and utilizes most of the standard readout circuit. This thesis discusses accelerometer response for electrical stimulus and BIST architecture. As a part of this BIST circuit, a second order sigma delta modulator has been designed. This modulator has a sampling frequency of 1MHz and bandwidth of 6KHz. SNDR of 60dB is achieved with 1Vpp differential input signal and 3.3V supply
ContributorsKundur, Vinay (Author) / Bakkaloglu, Bertan (Committee member) / Ozev, Sule (Committee member) / Kiaei, Sayfe (Committee member) / Arizona State University (Publisher)
Created2013
151010-Thumbnail Image.png
Description
Power supply management is important for MEMS (Micro-Electro-Mechanical-Systems) bio-sensing and chemical sensing applications. The dissertation focuses on discussion of accessibility to different power sources and supply tuning in sensing applications. First, the dissertation presents a high efficiency DC-DC converter for a miniaturized Microbial Fuel Cell (MFC). The miniaturized MFC produces

Power supply management is important for MEMS (Micro-Electro-Mechanical-Systems) bio-sensing and chemical sensing applications. The dissertation focuses on discussion of accessibility to different power sources and supply tuning in sensing applications. First, the dissertation presents a high efficiency DC-DC converter for a miniaturized Microbial Fuel Cell (MFC). The miniaturized MFC produces up to approximately 10µW with an output voltage of 0.4-0.7V. Such a low voltage, which is also load dependent, prevents the MFC to directly drive low power electronics. A PFM (Pulse Frequency Modulation) type DC-DC converter in DCM (Discontinuous Conduction Mode) is developed to address the challenges and provides a load independent output voltage with high conversion efficiency. The DC-DC converter, implemented in UMC 0.18µm technology, has been thoroughly characterized, coupled with the MFC. At 0.9V output, the converter has a peak efficiency of 85% with 9µW load, highest efficiency over prior publication. Energy could be harvested wirelessly and often has profound impacts on system performance. The dissertation reports a side-by-side comparison of two wireless and passive sensing systems: inductive and electromagnetic (EM) couplings for an application of in-situ and real-time monitoring of wafer cleanliness in semiconductor facilities. The wireless system, containing the MEMS sensor works with battery-free operations. Two wireless systems based on inductive and EM couplings have been implemented. The working distance of the inductive coupling system is limited by signal-to-noise-ratio (SNR) while that of the EM coupling is limited by the coupled power. The implemented on-wafer transponders achieve a working distance of 6 cm and 25 cm with a concentration resolution of less than 2% (4 ppb for a 200 ppb solution) for inductive and EM couplings, respectively. Finally, the supply tuning is presented in bio-sensing application to mitigate temperature sensitivity. The FBAR (film bulk acoustic resonator) based oscillator is an attractive method in label-free sensing application. Molecular interactions on FBAR surface induce mass change, which results in resonant frequency shift of FBAR. While FBAR has a high-Q to be sensitive to the molecular interactions, FBAR has finite temperature sensitivity. A temperature compensation technique is presented that improves the temperature coefficient of a 1.625 GHz FBAR-based oscillator from -118 ppm/K to less than 1 ppm/K by tuning the supply voltage of the oscillator. The tuning technique adds no additional component and has a large frequency tunability of -4305 ppm/V.
ContributorsZhang, Xu (Author) / Chae, Junseok (Thesis advisor) / Kiaei, Sayfe (Committee member) / Bakkaloglu, Bertan (Committee member) / Kozicki, Michael (Committee member) / Phillips, Stephen (Committee member) / Arizona State University (Publisher)
Created2012
134831-Thumbnail Image.png
Description
Graphene is a very strong two-dimensional material with a lot of potential applications in microelectromechanical systems (MEMS). In this research, graphene is being optimized for use in a 5 m x 5 m graphene resonator. To work properly, this graphene resonator must have a uniform strain across all manufactured devices.

Graphene is a very strong two-dimensional material with a lot of potential applications in microelectromechanical systems (MEMS). In this research, graphene is being optimized for use in a 5 m x 5 m graphene resonator. To work properly, this graphene resonator must have a uniform strain across all manufactured devices. To reduce strain induced in graphene sheets grown for use in these resonators, evaporated platinum has been used in this investigation due to its relatively lower surface roughness compared to copper films. The final goal is to have the layer of ultrathin platinum (<=200 nm) deposited on the MEMS graphene resonator and used to grow graphene directly onto the devices to remove the manual transfer step due to its inscalability. After growth, graphene is coated with polymer and the platinum is then etched. This investigation concentrated on the transfer process of graphene onto Si/SiO2 substrate from the platinum films. It was determined that the ideal platinum etchant was aqua regia at a volumetric ratio of 6:3:1 (H2O:HCl:HNO3). This concentration was dilute enough to preserve the polymer and graphene layer, but strong enough to etch within a day. Type and thickness of polymer support layers were also investigated. PMMA at a thickness of 200 nm was ideal because it was easy to remove with acetone and strong enough to support the graphene during the etch process. A reference growth recipe was used in this investigation, but now that the transfer has been demonstrated, growth can be optimized for even thinner films.
ContributorsCayll, David Richard (Author) / Tongay, Sefaattin (Thesis director) / Lee, Hyunglae (Committee member) / Mechanical and Aerospace Engineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2016-12
155924-Thumbnail Image.png
Description
Testing and calibration constitute a significant part of the overall manufacturing cost of microelectromechanical system (MEMS) devices. Developing a low-cost testing and calibration scheme applicable at the user side that ensures the continuous reliability and accuracy is a crucial need. The main purpose of testing is to eliminate defective devices

Testing and calibration constitute a significant part of the overall manufacturing cost of microelectromechanical system (MEMS) devices. Developing a low-cost testing and calibration scheme applicable at the user side that ensures the continuous reliability and accuracy is a crucial need. The main purpose of testing is to eliminate defective devices and to verify the qualifications of a product is met. The calibration process for capacitive MEMS devices, for the most part, entails the determination of the mechanical sensitivity. In this work, a physical-stimulus-free built-in-self-test (BIST) integrated circuit (IC) design characterizing the sensitivity of capacitive MEMS accelerometers is presented. The BIST circuity can extract the amplitude and phase response of the acceleration sensor's mechanics under electrical excitation within 0.55% of error with respect to its mechanical sensitivity under the physical stimulus. Sensitivity characterization is performed using a low computation complexity multivariate linear regression model. The BIST circuitry maximizes the use of existing analog and mixed-signal readout signal chain and the host processor core, without the need for computationally expensive Fast Fourier Transform (FFT)-based approaches. The BIST IC is designed and fabricated using the 0.18-µm CMOS technology. The sensor analog front-end and BIST circuitry are integrated with a three-axis, low-g capacitive MEMS accelerometer in a single hermetically sealed package. The BIST circuitry occupies 0.3 mm2 with a total readout IC area of 1.0 mm2 and consumes 8.9 mW during self-test operation.
ContributorsOzel, Muhlis Kenan (Author) / Bakkaloglu, Bertan (Thesis advisor) / Ozev, Sule (Thesis advisor) / Kiaei, Sayfe (Committee member) / Ogras, Umit Y. (Committee member) / Arizona State University (Publisher)
Created2017