153453-Thumbnail Image.png
Description
The present study describes audiovisual sentence recognition in normal hearing listeners, bimodal cochlear implant (CI) listeners and bilateral CI listeners. This study explores a new set of sentences (the AzAV sentences) that were created to have equal auditory intelligibility and equal gain from visual information.

The aims of Experiment I

The present study describes audiovisual sentence recognition in normal hearing listeners, bimodal cochlear implant (CI) listeners and bilateral CI listeners. This study explores a new set of sentences (the AzAV sentences) that were created to have equal auditory intelligibility and equal gain from visual information.

The aims of Experiment I were to (i) compare the lip reading difficulty of the AzAV sentences to that of other sentence materials, (ii) compare the speech-reading ability of CI listeners to that of normal-hearing listeners and (iii) assess the gain in speech understanding when listeners have both auditory and visual information from easy-to-lip-read and difficult-to-lip read sentences. In addition, the sentence lists were subjected to a multi-level text analysis to determine the factors that make sentences easy or difficult to speech read.

The results of Experiment I showed that (i) the AzAV sentences were relatively difficult to lip read, (ii) that CI listeners and normal-hearing listeners did not differ in lip reading ability and (iii) that sentences with low lip-reading intelligibility (10-15 % correct) provide about a 30 percentage point improvement in speech understanding when added to the acoustic stimulus, while sentences with high lip-reading intelligibility (30-60 % correct) provide about a 50 percentage point improvement in the same comparison. The multi-level text analyses showed that the familiarity of phrases in the sentences was the primary driving factor that affects the lip reading difficulty.

The aim of Experiment II was to investigate the value, when visual information is present, of bimodal hearing and bilateral cochlear implants. The results of Experiment II showed that when visual information is present, low-frequency acoustic hearing can be of value to speech understanding for patients fit with a single CI. However, when visual information was available no gain was seen from the provision of a second CI, i.e., bilateral CIs. As was the case in Experiment I, visual information provided about a 30 percentage point improvement in speech understanding.
ContributorsWang, Shuai (Author) / Dorman, Michael (Thesis advisor) / Berisha, Visar (Committee member) / Liss, Julie (Committee member) / Arizona State University (Publisher)
Created2015
153419-Thumbnail Image.png
Description
A multitude of individuals across the globe suffer from hearing loss and that number continues to grow. Cochlear implants, while having limitations, provide electrical input for users enabling them to "hear" and more fully interact socially with their environment. There has been a clinical shift to the

A multitude of individuals across the globe suffer from hearing loss and that number continues to grow. Cochlear implants, while having limitations, provide electrical input for users enabling them to "hear" and more fully interact socially with their environment. There has been a clinical shift to the bilateral placement of implants in both ears and to bimodal placement of a hearing aid in the contralateral ear if residual hearing is present. However, there is potentially more to subsequent speech perception for bilateral and bimodal cochlear implant users than the electric and acoustic input being received via these modalities. For normal listeners vision plays a role and Rosenblum (2005) points out it is a key feature of an integrated perceptual process. Logically, cochlear implant users should also benefit from integrated visual input. The question is how exactly does vision provide benefit to bilateral and bimodal users. Eight (8) bilateral and 5 bimodal participants received randomized experimental phrases previously generated by Liss et al. (1998) in auditory and audiovisual conditions. The participants recorded their perception of the input. Data were consequently analyzed for percent words correct, consonant errors, and lexical boundary error types. Overall, vision was found to improve speech perception for bilateral and bimodal cochlear implant participants. Each group experienced a significant increase in percent words correct when visual input was added. With vision bilateral participants reduced consonant place errors and demonstrated increased use of syllabic stress cues used in lexical segmentation. Therefore, results suggest vision might provide perceptual benefits for bilateral cochlear implant users by granting access to place information and by augmenting cues for syllabic stress in the absence of acoustic input. On the other hand vision did not provide the bimodal participants significantly increased access to place and stress cues. Therefore the exact mechanism by which bimodal implant users improved speech perception with the addition of vision is unknown. These results point to the complexities of audiovisual integration during speech perception and the need for continued research regarding the benefit vision provides to bilateral and bimodal cochlear implant users.
ContributorsLudwig, Cimarron (Author) / Liss, Julie (Thesis advisor) / Dorman, Michael (Committee member) / Azuma, Tamiko (Committee member) / Arizona State University (Publisher)
Created2015
137447-Thumbnail Image.png
Description
In this study, the Bark transform and Lobanov method were used to normalize vowel formants in speech produced by persons with dysarthria. The computer classification accuracy of these normalized data were then compared to the results of human perceptual classification accuracy of the actual vowels. These results were then analyzed

In this study, the Bark transform and Lobanov method were used to normalize vowel formants in speech produced by persons with dysarthria. The computer classification accuracy of these normalized data were then compared to the results of human perceptual classification accuracy of the actual vowels. These results were then analyzed to determine if these techniques correlated with the human data.
ContributorsJones, Hanna Vanessa (Author) / Liss, Julie (Thesis director) / Dorman, Michael (Committee member) / Borrie, Stephanie (Committee member) / Barrett, The Honors College (Contributor) / Department of Speech and Hearing Science (Contributor) / Department of English (Contributor) / Speech and Hearing Science (Contributor)
Created2013-05
134779-Thumbnail Image.png
Description
Pitch and timbre perception are two important dimensions of auditory perception. These aspects of sound aid the understanding of our environment, and contribute to normal everyday functioning. It is therefore important to determine the nature of perceptual interaction between these two dimensions of sound. This study tested the interactions between

Pitch and timbre perception are two important dimensions of auditory perception. These aspects of sound aid the understanding of our environment, and contribute to normal everyday functioning. It is therefore important to determine the nature of perceptual interaction between these two dimensions of sound. This study tested the interactions between pitch perception associated with the fundamental frequency (F0) and sharpness perception associated with the spectral slope of harmonic complex tones in normal hearing (NH) listeners and cochlear implant (CI) users. Pitch and sharpness ranking was measured without changes in the non-target dimension (Experiment 1), with different amounts of unrelated changes in the non-target dimension (Experiment 2), and with congruent/incongruent changes of similar perceptual salience in the non-target dimension (Experiment 3). The results showed that CI users had significantly worse pitch and sharpness ranking thresholds than NH listeners. Pitch and sharpness perception had symmetric interactions in NH listeners. However, for CI users, spectral slope changes significantly affected pitch ranking, while F0 changes had no significant effect on sharpness ranking. CI users' pitch ranking sensitivity was significantly better with congruent than with incongruent spectral slope changes. These results have important implications for CI processing strategies to better transmit pitch and timbre cues to CI users.
ContributorsSoslowsky, Samara Miranda (Author) / Luo, Xin (Thesis director) / Yost, William (Committee member) / Dorman, Michael (Committee member) / Department of Speech and Hearing Science (Contributor) / Barrett, The Honors College (Contributor)