Matching Items (4)
Filtering by

Clear all filters

136798-Thumbnail Image.png
Description
The purpose of this project was to examine the viability of protein biomarkers in pre-symptomatic detection of lung cancer. Regular screening has been shown to vastly improve patient survival outcome. Lung cancer currently has the highest occurrence and mortality of all cancers and so a means of screening would be

The purpose of this project was to examine the viability of protein biomarkers in pre-symptomatic detection of lung cancer. Regular screening has been shown to vastly improve patient survival outcome. Lung cancer currently has the highest occurrence and mortality of all cancers and so a means of screening would be highly beneficial. In this research, the biomarker neuron-specific enolase (Enolase-2, eno2), a marker of small-cell lung cancer, was detected at varying concentrations using electrochemical impedance spectroscopy in order to develop a mathematical model of predicting protein expression based on a measured impedance value at a determined optimum frequency. The extent of protein expression would indicate the possibility of the patient having small-cell lung cancer. The optimum frequency was found to be 459 Hz, and the mathematical model to determine eno2 concentration based on impedance was found to be y = 40.246x + 719.5 with an R2 value of 0.82237. These results suggest that this approach could provide an option for the development of small-cell lung cancer screening utilizing electrochemical technology.
ContributorsEvans, William Ian (Author) / LaBelle, Jeffrey (Thesis director) / Spano, Mark (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
136374-Thumbnail Image.png
Description
The Baby Friendly Hospital Initiative (BFHI) was created in 1991 with the goal to provide support and education to mothers on breastfeeding in order to increase the rate and duration of breastfeeding across the world. Despite being around for over 20 years, it has only been successfully incorporated into 245

The Baby Friendly Hospital Initiative (BFHI) was created in 1991 with the goal to provide support and education to mothers on breastfeeding in order to increase the rate and duration of breastfeeding across the world. Despite being around for over 20 years, it has only been successfully incorporated into 245 hospitals in the United States as of 2015. Due to the many benefits this initiative brings to mothers, infants, and the hospitals themselves as well as being shown to increase the incidence, duration, and exclusivity of breastfeeding, the goal of this project was to create a mother friendly brochure sharing this. The brochure was created in order to spread the word of the BFHI to expecting mothers so that they are informed and able to use this information to not only improve their own child-birthing experience but also push for implementation in their delivering facilities. The brochure covers additional topics such as breastfeeding benefits and tips, lactation resources, and steps to incorporate into their own hospital stay if outside of a BFHI facility in order to get a few of the benefits that the Baby Friendly Initiative provides. The brochure was tested for clarity, effectiveness, and for overall reactions in a study conducted at a local women's clinic surveying expectant mothers through the use of a short survey. These results were used to make minor improvements to the brochure before moving on to plans of how to disseminate the brochure to more clinics within the Phoenix area. The dissemination of this brochure will share this important information with women of childbearing age and hopefully lead to greater knowledge and progress towards improved maternal and neonatal outcomes.
ContributorsGunnare, Chrystina Jean (Author) / Whisner, Corrie (Thesis director) / Bever, Jennie (Committee member) / Barrett, The Honors College (Contributor) / School of Nutrition and Health Promotion (Contributor)
Created2015-05
134441-Thumbnail Image.png
Description
Improved pancreatic cancer diagnostic technology has the potential to improve patient prognosis by increasing cancer screening rates and encouraging early detection of the cancer. To increase the sensitivity and specificity while decreasing the cost and time investment, the emerging detection method of electrochemical impedance spectroscopy (EIS) was tested to detect

Improved pancreatic cancer diagnostic technology has the potential to improve patient prognosis by increasing cancer screening rates and encouraging early detection of the cancer. To increase the sensitivity and specificity while decreasing the cost and time investment, the emerging detection method of electrochemical impedance spectroscopy (EIS) was tested to detect two pancreatic cancer specific biomarkers. The antibodies of carcinoembryonic antigen and quiescin sulfhydryl oxidase 1 were immobilized individually to gold disk electrodes and tested for binding to their respective antigens. An AC signal of varying potential and a wide frequency sweep was applied to the electrode system and the resulting imaginary impedance values were analyzed. Based off of the highest slope and R-squared values of the collected impedance values, the optimal binding frequencies of QSOX1 and CEA with their antibodies was determined to be 97.66 Hz and 17.44 Hz, respectively. EIS was also used to test for potential multimarker detection by coimmobilizing anti-CEA and anti-QSOX1 to the surface of gold disk electrodes. Each system's impedance response was correlated to the physiological concentration range of CEA and QSOX1 individually. The resulting impedance and concentration calibration curves had R-squared values of 0.78 and 0.79 for the calculated QSOX1 and CEA, respectively. Both markers showed similar trends between the calculated and actual calibration curves for each marker. The imaginary impedance output lacks two independent peaks for the distinct optimal binding frequencies of both biomarkers after signal subtraction and show a large shift in optimal frequencies. From analyzing the co-immobilization data for the calculated and experimentally determined calibration curves of CEA and QSOX1, both curves had different correlation values between imaginary impedance values and concentration. Add and subtracting the experimental and calculated co-immobilization, QSOX1, and CEA signals suggest an oversaturation of QSOX1 used during the experiments.
ContributorsMalla, Akshara (Co-author) / Murali, Keerthana (Co-author) / LaBelle, Jeffrey (Thesis director) / Lin, Chi-En (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2017-05
134280-Thumbnail Image.png
Description
As of today, there does not exist a cheap diagnostic for lactate for use in trauma centers. $671 billion are spent on trauma accidents and emergency rooms, with money focused on treatments such as YSI and ELISA, costing $1500 and $200, respectively. Gold disk electrodes were used to immobilize lactate

As of today, there does not exist a cheap diagnostic for lactate for use in trauma centers. $671 billion are spent on trauma accidents and emergency rooms, with money focused on treatments such as YSI and ELISA, costing $1500 and $200, respectively. Gold disk electrodes were used to immobilize lactate dehydrogenase and glucose oxidase, with electrochemical impedance spectroscopy (EIS) used as the method for detection. Two lactate experimental runs were completed with data detailing a linear model and positive correlation for imaginary impedance and concentration, and one glucose experimental run was completed proving that a continuous system can be completed accounting for reaction and consumption using EIS, a process previously not done before.
ContributorsEltohamy, Omar Khaled (Author) / LaBelle, Jeffrey (Thesis director) / Lin, Chi-En (Committee member) / Harrington Bioengineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2017-05