Matching Items (3)
Filtering by

Clear all filters

151356-Thumbnail Image.png
Description
A thorough exploration of star formation necessitates observation across the electromagnetic spectrum. In particular, observations in the submillimeter and ultra-violet allow one to observe very early stage star formation and to trace the evolution from molecular cloud collapse to stellar ignition. Submillimeter observations are essential for piercing the heart of

A thorough exploration of star formation necessitates observation across the electromagnetic spectrum. In particular, observations in the submillimeter and ultra-violet allow one to observe very early stage star formation and to trace the evolution from molecular cloud collapse to stellar ignition. Submillimeter observations are essential for piercing the heart of heavily obscured stellar nurseries to observe star formation in its infancy. Ultra-violet observations allow one to observe stars just after they emerge from their surrounding environment, allowing higher energy radiation to escape. To make detailed observations of early stage star formation in both spectral regimes requires state-of-the-art detector technology and instrumentation. In this dissertation, I discuss the calibration and feasibility of detectors developed by Lawrence Berkeley National Laboratory and specially processed at the Jet Propulsion Laboratory to increase their quantum efficiency at far-ultraviolet wavelengths. A cursory treatment of the delta-doping process is presented, followed by a thorough discussion of calibration procedures developed at JPL and in the Laboratory for Astronomical and Space Instrumentation at ASU. Subsequent discussion turns to a novel design for a Modular Imager Cell forming one possible basis for construction of future large focal plane arrays. I then discuss the design, fabrication, and calibration of a sounding rocket imaging system developed using the MIC and these specially processed detectors. Finally, I discuss one scientific application of sub-mm observations. I used data from the Heinrich Hertz Sub-millimeter Telescope and the Sub-Millimeter Array (SMA) to observe sub-millimeter transitions and continuum emission towards AFGL 2591. I tested the use of vibrationally excited HCN emission to probe the protostellar accretion disk structure. I measured vibrationally excited HCN line ratios in order to elucidate the appropriate excitation mechanism. I find collisional excitation to be dominant, showing the emission originates in extremely dense (n&sim10;11 cm-3), warm (T&sim1000; K) gas. Furthermore, from the line profile of the v=(0, 22d, 0) transition, I find evidence for a possible accretion disk.
ContributorsVeach, Todd Justin (Author) / Scowen, Paul A (Thesis advisor) / Groppi, Christopher E (Thesis advisor) / Beasley, Matthew N (Committee member) / Rhoads, James E (Committee member) / Windhorst, Rogier A (Committee member) / Arizona State University (Publisher)
Created2012
133764-Thumbnail Image.png
Description
An improved system for wireless neurostimulation was investigated through the design and development of sub-millimeter piezoelectric devices. The devices build on prior work in the lab, which was limited by device size and required surgical implantation. A method of manufacturing sub-mm devices was developed, and utilized to construct this new

An improved system for wireless neurostimulation was investigated through the design and development of sub-millimeter piezoelectric devices. The devices build on prior work in the lab, which was limited by device size and required surgical implantation. A method of manufacturing sub-mm devices was developed, and utilized to construct this new design. The device frequency response was characterized and its resonant modes and output voltages determined through a Fast Fourier Transform. The fundamental thickness mode frequency was found to be 15.4MHz with a corresponding 10.25mV amplitude, and a longitudinal resonant frequency of 3.1Mhz with a corresponding 2.2mV amplitude across a 50Ω resistor. The high miniaturization of the device holds promise for future work for creating an injectable, wireless system for the treatment of neurological disorders.
ContributorsCatchings, Michael Thomas (Author) / Towe, Bruce (Thesis director) / Muthuswamy, Jitendran (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2018-05
135303-Thumbnail Image.png
Description
Balloon-borne telescopes are an economic alternative to scientists seeking to study light compared to other ground- and space-based alternatives, such as the Keck Observatory and the Hubble Space Telescope. One such balloon-borne telescope is the Balloon-borne Large Aperture Submillimeter Telescope, or simply BLAST. Arizona State University was tasked with assembling

Balloon-borne telescopes are an economic alternative to scientists seeking to study light compared to other ground- and space-based alternatives, such as the Keck Observatory and the Hubble Space Telescope. One such balloon-borne telescope is the Balloon-borne Large Aperture Submillimeter Telescope, or simply BLAST. Arizona State University was tasked with assembling one of the primary optics plates for the telescope's next mission. This plate, detailed in the following paragraphs, is designed to detect and capture submillimeter wavelength light. This will help scientists understand the formation and early life of stars. Due to its highly sensitive nature detecting light, the optics plate had to be carefully assembled following a strict assembly and testing procedure. Initially, error tolerances for the mirrors and plate were developed using a computer model, later to be compared to measured values. The engineering decisions made throughout the process pertained to every aspect of the plate, from ensuring the compliance of the engineering drawings to the polishing of the mirrors for testing. The assembly procedure itself was verified at the conclusion using a coordinate measuring machine (CMM) to analyze whether or not the plate was within defined error tolerances mentioned above. This data was further visualized within the document to show that the assembly procedure of the BLAST optics plate was successful. The largest error margins seen were approximately one order of magnitude lower than their tolerated limits, reflecting good engineering judgement and care applied to the manufacturing process. The plate has since been shipped offsite to continue testing and the assembly team is confident it will perform well within expected parameters.
ContributorsDombrowski, Shane Matthew (Author) / Groppi, Christopher (Thesis director) / Mauskopf, Philip (Committee member) / Underhill, Matthew (Committee member) / Mechanical and Aerospace Engineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05