Matching Items (3)
Filtering by

Clear all filters

157473-Thumbnail Image.png
Description
The goal of this research was to study the effect of dilution on ammonium and potassium removal from real hydrolyzed urine. The performance of two natural zeolites, clinoptilolite and chabazite, was studied and compared with the help of batch equilibrium experiments at four dilution levels: 100%, 10%, 1% and 0.1%

The goal of this research was to study the effect of dilution on ammonium and potassium removal from real hydrolyzed urine. The performance of two natural zeolites, clinoptilolite and chabazite, was studied and compared with the help of batch equilibrium experiments at four dilution levels: 100%, 10%, 1% and 0.1% (urine volume/total solution volume). Further, the sorption behavior of other exchangeable ions (sodium, calcium and magnesium) in clinoptilolite and chabazite was studied to improve the understanding of ion exchange stoichiometry. Ammonium and potassium removal were highest at undiluted level in samples treated with clinoptilolite. This is a key finding as it illustrates the benefit of urine source separation. Chabazite treated samples showed highest ammonium and potassium removal at undiluted level at lower doses. At higher doses, potassium removal was similar in undiluted and 10% urine solutions whereas ammonium removal was the highest in 10% urine solutions. In general, chabazite showed higher ammonium and potassium removal than clinoptilolite. The result showed that ion exchange was stoichiometric in solutions with higher urine volumes.
ContributorsRegmi, Urusha (Author) / Boyer, Treavor H (Thesis advisor) / Delgado, Anca G (Committee member) / Hamilton, Kerry (Committee member) / Arizona State University (Publisher)
Created2019
137098-Thumbnail Image.png
Description
This paper summarizes the [1] ideas behind, [2] needs, [3] development, and [4] testing of 3D-printed sensor-stents known as Stentzors. This sensor was successfully developed entirely from scratch, tested, and was found to have an output of 3.2*10-6 volts per RMS pressure in pascals. This paper also recommends further work

This paper summarizes the [1] ideas behind, [2] needs, [3] development, and [4] testing of 3D-printed sensor-stents known as Stentzors. This sensor was successfully developed entirely from scratch, tested, and was found to have an output of 3.2*10-6 volts per RMS pressure in pascals. This paper also recommends further work to render the Stentzor deployable in live subjects, including [1] further design optimization, [2] electrical isolation, [3] wireless data transmission, and [4] testing for aneurysm prevention.
ContributorsMeidinger, Aaron Michael (Author) / LaBelle, Jeffrey (Thesis director) / Frakes, David (Committee member) / Barrett, The Honors College (Contributor) / Mechanical and Aerospace Engineering Program (Contributor)
Created2014-05
161280-Thumbnail Image.png
Description
This dissertation focused on the implementation of urine diversion systems in commercial and institutional buildings in the United States with a focus on control of the urea hydrolysis reaction. Urine diversion is the process by which urine is separately collected at the source in order to realize system benefits, including

This dissertation focused on the implementation of urine diversion systems in commercial and institutional buildings in the United States with a focus on control of the urea hydrolysis reaction. Urine diversion is the process by which urine is separately collected at the source in order to realize system benefits, including water conservation, nutrient recovery, and pharmaceutical removal. Urine diversion systems depend greatly on the functionality of nonwater urinals and urine diverting toilets, which are needed to collect undiluted urine. However, the urea hydrolysis reaction creates conditions that lead to precipitation in the fixtures due to the increase in pH from 6 to 9 as ammonia and bicarbonate are produced. Chapter 2 and Chapter 3 describes the creation and use of a cyber-physical system (CPS) to monitor and control urea hydrolysis in the urinal testbed. Two control logics were used to control urea hydrolysis in realistic restroom conditions. In the experiments, acid was added to inhibit urea hydrolysis during periods of high and low building occupancy. These results were able to show that acid should be added based on the restroom use in order to efficiently inhibit urea hydrolysis. Chapter 4 advanced the results from Chapter 3 by testing the acid addition control logics in a real restroom with the urinal-on-wheels. The results showed that adding acid during periods of high building occupancy equated to the least amount of acid added and allowed for urea hydrolysis inhibition. This study also analyzed the bacterial communities of the collected urine and found that acid addition changed the structure of the bacterial communities. Chapter 5 showed an example of the capabilities of a CPS when implemented in CI buildings. The study used data mining methods to predict chlorine residuals in premise plumbing in a CI green building. The results showed that advance modeling methods were able to model the system better than traditional methods. These results show that CPS technology can be used to illuminate systems and can provide information needed to understand conditions within CI buildings.
ContributorsSaetta, Daniella (Author) / Boyer, Treavor H (Thesis advisor) / Hamilton, Kerry (Committee member) / Ross, Heather M. (Committee member) / Boscovic, Dragan (Committee member) / Arizona State University (Publisher)
Created2021