Matching Items (20)
149631-Thumbnail Image.png
Description
Different environmental factors, such as ultraviolet radiation (UV), relative humidity (RH) and the presence of reducing gases (acetone and ethanol), play an important role in the daily life of human beings. UV is very important in a number of areas, such as astronomy, resin curing of polymeric materials, combustion engineering,

Different environmental factors, such as ultraviolet radiation (UV), relative humidity (RH) and the presence of reducing gases (acetone and ethanol), play an important role in the daily life of human beings. UV is very important in a number of areas, such as astronomy, resin curing of polymeric materials, combustion engineering, water purification, flame detection and biological effects with more recent proposals like early missile plume detection, secure space-to-space communications and pollution monitoring. RH is a very common parameter in the environment. It is essential not only for human comfort, but also for a broad spectrum of industries and technologies. There is a substantial interest in the development of RH sensors for applications in monitoring moisture level at home, in clean rooms, cryogenic processes, medical and food science, and so on. The concentration of acetone and other ketone bodies in the exhaled air can serve as an express noninvasive diagnosis of ketosis. Meanwhile, driving under the influence of alcohol is a serious traffic violation and this kind of deviant behavior causes many accidents and deaths on the highway. Therefore, the detection of ethanol in breath is usually used as a quick and reliable screening method for the sobriety checkpoint. Traditionally, semiconductor metal oxide sensors are the major candidates employed in the sensing applications mentioned above. However, they suffer from the low sensitivity, poor selectivity and huge power consumption. In this dissertation, Zinc Oxide (ZnO) based Film Bulk Acoustic Resonator (FBAR) was developed to monitor UV, RH, acetone and ethanol in the environment. FBAR generally consists of a sputtered piezoelectric thin film (ZnO/AlN) sandwiched between two electrodes. It has been well developed both as filters and as high sensitivity mass sensors in recent years. FBAR offers high sensitivity and excellent selectivity for various environment monitoring applications. As the sensing signal is in the frequency domain, FABR has the potential to be incorporated in a wireless sensor network for remote sensing. This study extended our current knowledge of FBAR and pointed out feasible directions for future exploration.
ContributorsQiu, Xiaotun (Author) / Yu, Hongyu (Thesis advisor) / Christen, Jennifer Blain (Committee member) / Aberle, James T., 1961- (Committee member) / Jiang, Hanqing (Committee member) / Arizona State University (Publisher)
Created2011
149615-Thumbnail Image.png
Description
This thesis presents a gas sensor readout IC for amperometric and conductometric electrochemical sensors. The Analog Front-End (AFE) readout circuit enables tracking long term exposure to hazardous gas fumes in diesel and gasoline equipments, which may be correlated to diseases. Thus, the detection and discrimination of gases using microelectronic gas

This thesis presents a gas sensor readout IC for amperometric and conductometric electrochemical sensors. The Analog Front-End (AFE) readout circuit enables tracking long term exposure to hazardous gas fumes in diesel and gasoline equipments, which may be correlated to diseases. Thus, the detection and discrimination of gases using microelectronic gas sensor system is required. This thesis describes the research, development, implementation and test of a small and portable based prototype platform for chemical gas sensors to enable a low-power and low noise gas detection system. The AFE reads out the outputs of eight conductometric sensor array and eight amperometric sensor arrays. The IC consists of a low noise potentiostat, and associated 9bit current-steering DAC for sensor stimulus, followed by the first order nested chopped £U£G ADC. The conductometric sensor uses a current driven approach for extracting conductance of the sensor depending on gas concentration. The amperometric sensor uses a potentiostat to apply constant voltage to the sensors and an I/V converter to measure current out of the sensor. The core area for the AFE is 2.65x0.95 mm2. The proposed system achieves 91 dB SNR at 1.32 mW quiescent power consumption per channel. With digital offset storage and nested chopping, the readout chain achieves 500 fÝV input referred offset.
ContributorsKim, Hyun-Tae (Author) / Bakkaloglu, Bertan (Thesis advisor) / Vermeire, Bert (Committee member) / Spanias, Andreas (Committee member) / Thornton, Trevor (Committee member) / Arizona State University (Publisher)
Created2011
149395-Thumbnail Image.png
Description
The RADiation sensitive Field Effect Transistor (RADFET) has been conventionally used to measure radiation dose levels. These dose sensors are calibrated in such a way that a shift in threshold voltage, due to a build-up of oxide-trapped charge, can be used to estimate the radiation dose. In order to estimate

The RADiation sensitive Field Effect Transistor (RADFET) has been conventionally used to measure radiation dose levels. These dose sensors are calibrated in such a way that a shift in threshold voltage, due to a build-up of oxide-trapped charge, can be used to estimate the radiation dose. In order to estimate the radiation dose level using RADFET, a wired readout circuit is necessary. Using the same principle of oxide-trapped charge build-up, but by monitoring the change in capacitance instead of threshold voltage, a wireless dose sensor can be developed. This RADiation sensitive CAPacitor (RADCAP) mounted on a resonant patch antenna can then become a wireless dose sensor. From the resonant frequency, the capacitance can be extracted which can be mapped back to estimate the radiation dose level. The capacitor acts as both radiation dose sensor and resonator element in the passive antenna loop. Since the MOS capacitor is used in passive state, characterizing various parameters that affect the radiation sensitivity is essential. Oxide processing technique, choice of insulator material, and thickness of the insulator, critically affect the dose response of the sensor. A thicker oxide improves the radiation sensitivity but reduces the dynamic range of dose levels for which the sensor can be used. The oxide processing scheme primarily determines the interface trap charge and oxide-trapped charge development; controlling this parameter is critical to building a better dose sensor.
ContributorsSrinivasan Gopalan, Madusudanan (Author) / Barnaby, Hugh (Thesis advisor) / Holbert, Keith E. (Committee member) / Yu, Hongyu (Committee member) / Arizona State University (Publisher)
Created2010
155660-Thumbnail Image.png
Description
This work describes the development of a device for measuring CO2 in breath, which has applications in monitoring a variety of health issues, such as Chronic Obstructive Pulmonary Disease (COPD), asthma, and cardiovascular disease. The device takes advantage of colorimetric sensing technology in order to maintain a low cost and

This work describes the development of a device for measuring CO2 in breath, which has applications in monitoring a variety of health issues, such as Chronic Obstructive Pulmonary Disease (COPD), asthma, and cardiovascular disease. The device takes advantage of colorimetric sensing technology in order to maintain a low cost and high user-friendliness. The sensor consists of a pH dye, reactive element, and base coated on a highly porous Teflon membrane. The transmittance of the sensor is measured in the device via a simple LED/photodiode system, along with the flow rate, ambient relative humidity, and barometric pressure. The flow is measured by a newly developed flow meter described in this work, the Confined Pitot Tube (CPT) flow meter, which provides a high accuracy with reduced flow-resistance with a standard differential pressure transducer. I demonstrate in this work that the system has a high sensitivity, high specificity, fast time-response, high reproducibility, and good stability. The sensor has a simple calibration method which requires no action by the user, and utilizes a sophisticated, yet lightweight, model in order to predict temperature changes on the sensor during breathing and track changes in water content. It is shown to be effective for measuring CO2 waveform parameters on a breath-by-breath basis, such as End-Tidal CO2, Alveolar Plateau Slope, and Beginning Exhalation Slope.
ContributorsBridgeman, Devon (Author) / Forzani, Erica S (Thesis advisor) / Nikkhah, Mehdi (Committee member) / Holloway, Julianne (Committee member) / Raupp, Gregory (Committee member) / Emady, Heather (Committee member) / Arizona State University (Publisher)
Created2017
187367-Thumbnail Image.png
Description
Non-invasive biosensors enable rapid, real-time measurement and quantification of biological processes, such as metabolic state. Currently, the most accurate metabolic sensors are invasive, and significant cost is required, with few exceptions, to achieve similar accuracy using non-invasive methods. This research, conducted within the Biodesign Institute Center for Bioelectronics and Biosensors,

Non-invasive biosensors enable rapid, real-time measurement and quantification of biological processes, such as metabolic state. Currently, the most accurate metabolic sensors are invasive, and significant cost is required, with few exceptions, to achieve similar accuracy using non-invasive methods. This research, conducted within the Biodesign Institute Center for Bioelectronics and Biosensors, leverages the selective reactivity of a chemical sensing solution to develop a sensor which measures acetone in the breath for ketosis and ketoacidosis diagnostics, which is relevant to body weight management and type I diabetes. The sensor displays a gradient of color changes, and the absorbance change is proportional to the acetone concentration in the part- per-million range, making applicable for detection ketosis and ketoacidosis in human breath samples. The colorimetric sensor response can be fitted to a Langmuir-like model for sensor calibration. The sensors best performance comes with turbulent, continuous exposure to the samples, rather than batch sample exposure. With that configuration, these novel sensors offer significant improvements to clinical and at- home measurement of ketosis and ketoacidosis.
ContributorsDenham, Landon (Author) / Forzani, Erica (Thesis advisor) / Wang, Shaopeng (Committee member) / Kulick, Doina (Committee member) / Arizona State University (Publisher)
Created2023
171362-Thumbnail Image.png
Description
Emerging interest in research of polymeric biomaterials towards human health has intrigued me to pursue my graduate research, primarily towards a few biomedical applications like radiation dosimetry, drug & gene delivery systems. Although Radiotherapy remains a foundation of cancer treatment procedures in clinic; overdosing of radiation can induce toxicity to

Emerging interest in research of polymeric biomaterials towards human health has intrigued me to pursue my graduate research, primarily towards a few biomedical applications like radiation dosimetry, drug & gene delivery systems. Although Radiotherapy remains a foundation of cancer treatment procedures in clinic; overdosing of radiation can induce toxicity to sensitive organs and underexposure can lead to low efficacies of tumor treatment. Commercial sensors consist of several intrinsic disadvantages due to their sensitivity to heat and light, long processing times, and high costs. For real-time dose detection, a novel colorimetric hydrogel sensor was developed with formation of maroon-colored gold nanoparticles (templated by a variety of surfactants and amino acids) within an agarose-based polymeric hydrogel, upon exposure of ionizing radiation. Translational potential of sensor was demonstrated using anthropomorphic phantoms and in live canine patients undergoing radiotherapy treatments by qualitatively and quantitatively measuring the delivered dose. Combination therapy by simultaneously using drug & gene delivery with a single multifunctional carrier can lead to novel treatment modalities for various diseases like Cancer, Alzheimer etc. A library of lipid-based Aminoglycoside-derived cationic self-assembling polymer nanoparticles (LPNs) was developed with size ranging from (50-150) nm. Lead LPNs showed great potential for concurrent delivery of nucleic acids along with small molecule drug such as histone deacetylase (HDAC) inhibitor, AR-42 as a combination treatment to cancer cells.
ContributorsDutta, Subhadeep (Author) / Yarger, Jeffery JL (Thesis advisor) / Stephanopoulos, Nicholas NS (Committee member) / Pannala, Rahul RP (Committee member) / Arizona State University (Publisher)
Created2022
171665-Thumbnail Image.png
Description
Microbial Potentiometric Sensors (MPS) utilize endemic biofilms to generate a signal using a measurable potentiometric difference, without the use of cleaning, maintenance, and reagents of conventional sensor monitoring methods. These advantages are suitable for monitoring bioreactions in water distribution systems, soils, and wastewater treatment. In controlled fermentation processes, monitoring seeks

Microbial Potentiometric Sensors (MPS) utilize endemic biofilms to generate a signal using a measurable potentiometric difference, without the use of cleaning, maintenance, and reagents of conventional sensor monitoring methods. These advantages are suitable for monitoring bioreactions in water distribution systems, soils, and wastewater treatment. In controlled fermentation processes, monitoring seeks to avoid contamination and degradation, which results in loss of productivity. MPS have yet to be applied to monitor the fermentation of milk to yogurt. This study examined the feasibility of using MPS technology to monitor the progress of milk fermentation in real-time with a bench-scale model bioreactor. Signal data obtained by the MPS was analyzed and assessed for the ability to model and predict the time of complete fermentation. Analysis of complete fermentation times in conjunction with pH and MPS signal values found characteristics indicative of complete fermentation. The method detection limit was assessed to inform of the method’s capacity to distinguish complete fermentation time. A sensitivity analysis was conducted to develop a more robust method for predicting complete fermentation time. At this proof-of-concept scale, MPS successfully performed in this capacity to monitor bioreaction conditions continuously. MPS captured information as fermentation progressed, was completed, and as the yogurt product naturally began to decay. Analysis of the data obtained with the technology found predictions of complete fermentation time within a two hour range, with further assessment in the sensitivity analysis narrowing this timeframe to less than 45 minutes. This study revealed the challenges in precisely predicting complete fermentation;however, advancement of a robust analytical method and demonstration of technical feasibility promotes further MPS technology applications that seek to monitor conditions in real-time to preserve health and production.
ContributorsDieter, Lucien Andres (Author) / Hristovski, Kirl D. (Thesis advisor) / Olson, Larry W. (Committee member) / Ünver, Olcay (Committee member) / Arizona State University (Publisher)
Created2021
171712-Thumbnail Image.png
Description
Cardiovascular disease is affecting millions of people worldwide and is the leading cause of death in the United States. This disease is closely related to the abnormal creatinine levels in blood. For this reason, there is a need for a low-cost point-of-care device that could measure the creatinine level in

Cardiovascular disease is affecting millions of people worldwide and is the leading cause of death in the United States. This disease is closely related to the abnormal creatinine levels in blood. For this reason, there is a need for a low-cost point-of-care device that could measure the creatinine level in blood with the goal of managing and preventing cardiovascular disease. This project introduces a Molecular Reactive Lateral Flow Assay (MoReLFA) device that is aimed toward creatinine detection based on an optimized chemical reaction of creatinine and alkaline picrate. The device consists of different membranes that accommodate 50 microliters of fluid sample and carry out a colorimetric reaction, in which deposited-colored region is analyzed for Red, Green, and Blue (RGB) components via an image processing software. The color intensity from the RGB outputs was then studied and compared with a gold standard spectrophotometry-based technique. The results show that the MoReLFA sensor could successfully detect creatinine levels in standard solutions. The plot of the sensor color intensity against the absorbance from spectrophotometry shows a good correlation between the two methods (R2 = 0.96). Furthermore, the paper introduces the development of a RGB reader box that is portable and for easy assessment of RGB values. The color intensity from the box shows an increasing trend with increasing creatinine concentrations; and the coefficient of determination of this relationship is 0.85.
ContributorsNguyen, Ngan Anh (Author) / Raupp, Gregory (Thesis advisor) / Forzani, Erica (Thesis advisor) / Mora, Sabrina Jimena (Committee member) / Arizona State University (Publisher)
Created2022
158586-Thumbnail Image.png
Description
Abnormally low or high blood iron levels are common health conditions worldwide and can seriously affect an individual’s overall well-being. A low-cost point-of-care technology that measures blood iron markers with a goal of both preventing and treating iron-related disorders represents a significant advancement in medical care delivery systems. Methods: A

Abnormally low or high blood iron levels are common health conditions worldwide and can seriously affect an individual’s overall well-being. A low-cost point-of-care technology that measures blood iron markers with a goal of both preventing and treating iron-related disorders represents a significant advancement in medical care delivery systems. Methods: A novel assay equipped with an accurate, storable, and robust dry sensor strip, as well as a smartphone mount and (iPhone) app is used to measure total iron in human serum. The sensor strip has a vertical flow design and is based on an optimized chemical reaction. The reaction strips iron ions from blood-transport proteins, reduces Fe(III) to Fe(II), and chelates Fe(II) with ferene, with the change indicated by a blue color on the strip. The smartphone mount is robust and controls the light source of the color reading App, which is calibrated to obtain output iron concentration results. The real serum samples are then used to assess iron concentrations from the new assay and validated through intra-laboratory and inter-laboratory experiments. The intra-laboratory validation uses an optimized iron detection assay with multi-well plate spectrophotometry. The inter-laboratory validation method is performed in a commercial testing facility (LabCorp). Results: The novel assay with the dry sensor strip and smartphone mount, and App is seen to be sensitive to iron detection with a dynamic range of 50 - 300 µg/dL, sensitivity of 0.00049 µg/dL, coefficient of variation (CV) of 10.5%, and an estimated detection limit of ~15 µg/dL These analytical specifications are useful for predicting iron deficiency and overloads. The optimized reference method has a sensitivity of 0.00093 µg/dL and CV of 2.2%. The correlation of serum iron concentrations (N=20) between the optimized reference method and the novel assay renders a slope of 0.95, and a regression coefficient of 0.98, suggesting that the new assay is accurate. Lastly, a spectrophotometric study of the iron detection reaction kinetics is seen to reveal the reaction order for iron and chelating agent. Conclusion: The new assay is able to provide accurate results in intra- and inter- laboratory validations and has promising features of both mobility and low-cost.
ContributorsSerhan, Michael (Author) / Forzani, Erica (Thesis advisor) / Raupp, Gregory (Committee member) / Acharya, Abhinav (Committee member) / Hu, Tony (Committee member) / Smith, Barbara (Committee member) / Arizona State University (Publisher)
Created2020
132606-Thumbnail Image.png
Description
Piloerection (known as goosebumps) is mediated by activation of alpha-adrenergic receptors within the sympathetic branch of the autonomic nervous system. The study of piloerection is important in multiple fields, from emotion studies to nervous system pathology. This makes piloerection particularly relevant to emotions research. Despite wide-ranging applications, current methods for

Piloerection (known as goosebumps) is mediated by activation of alpha-adrenergic receptors within the sympathetic branch of the autonomic nervous system. The study of piloerection is important in multiple fields, from emotion studies to nervous system pathology. This makes piloerection particularly relevant to emotions research. Despite wide-ranging applications, current methods for measuring piloerection are laborious and qualitative. The goal of this study is to build a wearable piloerection sensor through the use of straight-line lasers and photoresistors. The study analyzed methods of detecting and measuring goosebumps, and applied the method of laser scattering as a detection method. This device was designed and tested against a population of seven Arizona State University students. Goosebumps were elicited through conditions of cold, and video clips meant to elicit emotions of awe and sadness. Piloerection was then quantified through two controls of self-identification and camera recording, as well as the new detection method. These were then compared together, and it was found that subjective methods of determining goosebumps did not correlate well with objective measurements, but that the two objective measurements correlated well with one another. This shows that the technique of laser scattering can be used to detect goosebumps and further developments on this new detection method will be made. Moreover, the presence of uncorrelated subjective measurements further shows the need for an objective measurement of piloerection, while also bringing into question other factors that may be confused with the feeling of piloerection, such as chills or shivers. This study further reaffirmed previous studies showing a positive correlation between intense emotions.
ContributorsHemesath, Angela (Author) / Muthuswamy, Jitendran (Thesis director) / Shiota, Michelle (Lani) (Committee member) / Harrington Bioengineering Program (Contributor, Contributor) / School of Molecular Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2019-05