In these times of increasing industrialization, there arises a need for effective and energy efficient heat transfer/heat exchange devices. The focus nowadays is on identifying various methods and techniques which can aid the process of developing energy efficient devices. One of the most common heat transfer devices is a heat

In these times of increasing industrialization, there arises a need for effective and energy efficient heat transfer/heat exchange devices. The focus nowadays is on identifying various methods and techniques which can aid the process of developing energy efficient devices. One of the most common heat transfer devices is a heat exchanger. Heat exchangers are an essential commodity to any industry and their efficiency can play an important role in making industries energy efficient and reduce the energy losses in the devices, in turn decreasing energy inputs to run the industry.

One of the ways in which we can improve the efficiency of heat exchangers is by applying ultrasonic energy to a heat exchanger. This research explores the possibility of introducing the external input of ultrasonic energy to increase the efficiency of the heat exchanger. This increase in efficiency can be estimated by calculating the parameters important for the characterization of a heat exchanger, which are effectiveness (ε) and overall heat transfer coefficient (U). These parameters are calculated for both the non-ultrasound and ultrasound conditions in the heat exchanger.

This a preliminary study of ultrasound and its effect on a conventional shell-and-coil heat exchanger. From the data obtained it can be inferred that the increase in effectiveness and overall heat transfer coefficient upon the application of ultrasound is 1% and 6.22% respectively.
ContributorsAnnam, Roshan Sameer (Author) / Phelan, Patrick (Thesis advisor) / Rykaczewski, Konrad (Committee member) / Milcarek, Ryan (Committee member) / Arizona State University (Publisher)
Created2019
134375-Thumbnail Image.png
Description
To determine the effects of exhaust heat recovery systems on small engines, an experiment was performed to measure the power losses of an engine with restricted exhaust flow. In cooperation with ASU's SAE Formula race team, a water brake dynamometer was refurbished and connected to the 2017 racecar engine. The

To determine the effects of exhaust heat recovery systems on small engines, an experiment was performed to measure the power losses of an engine with restricted exhaust flow. In cooperation with ASU's SAE Formula race team, a water brake dynamometer was refurbished and connected to the 2017 racecar engine. The engine was mounted with a diffuser disc exhaust to restrict flow, and a pressure sensor was installed in the O2 port to measure pressure under different restrictions. During testing, problems with the equipment prevented suitable from being generated. Using failure root cause analysis, the failure modes were identified and plans were made to resolve those issues. While no useful data was generated, the project successfully rebuilt a dynamometer for students to use for future engine research.
ContributorsRoss, Zachary David (Author) / Middleton, James (Thesis director) / Steele, Bruce (Committee member) / Mechanical and Aerospace Engineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2017-05
168808-Thumbnail Image.png
Description
Dehumidifiers are ubiquitous and essential household appliances in many parts of the world. They are used extensively in tropical and sub-tropical environments to lower humidity in living spaces, where high ambient humidity can lead to numerous negative health effects from mild physical discomfort to more serious conditions such as mold

Dehumidifiers are ubiquitous and essential household appliances in many parts of the world. They are used extensively in tropical and sub-tropical environments to lower humidity in living spaces, where high ambient humidity can lead to numerous negative health effects from mild physical discomfort to more serious conditions such as mold build up in structures and dangerous illnesses in humans. Most common dehumidifiers are based on conventional mechanical refrigeration cycles, where the effects of condensation heat transfer play a critical role in their effectiveness. In these devices, humid ambient air flows over a cold evaporator, which lowers the temperature of the humid ambient air below its dew point temperature and therefore decreases its water content by causing liquid water condensation on the evaporator surface. The rate at which humidity can be extracted from the ambient air is governed in part by how quickly the evaporator can shed the condensed droplets. Recent advances in soft, stretchable, thermally enhanced (through the addition of liquid metals) silicone tubing offer the potential to use these stretchable tubes in place of conventional copper pipe for applications such as dehumidification. Copper is a common material choice for dehumidifier evaporator tubing owing to its ubiquity and its high thermal conductivity, but it has several thermal downsides. Specifically, copper tubes remain static and typically rely on gravity alone to remove water droplets when they reach a sufficient mass. Additionally, copper’s naturally hydrophilic surface promotes film-wise condensation, which is substantially less effective than dropwise condensation. In contrast to copper, thermally enhanced soft stretchable tubes have naturally hydrophobic surfaces that promote the more effective dropwise condensation mode and a soft surface that offers higher nucleation density. However, soft surfaces also increase droplet pinning, which inhibits their departure. This work experimentally explores the effects of periodic axial stretching and retraction of soft tubing internally cooled with water on droplet condensation dynamics on its exterior surface. Results are discussed in terms of overall system thermal performance and real-time condensation imaging. An overall null result is discovered, and recommendations for future experiments are made.
Contributorsnordstog, thomas (Author) / Rykaczewski, Konrad (Thesis advisor) / Wang, Robert (Committee member) / Devasenathipathy, Shankar (Committee member) / Arizona State University (Publisher)
Created2022
157667-Thumbnail Image.png
Description
In nature, it is commonly observed that animals and birds perform movement-based thermoregulation activities to regulate their body temperatures. For example, flapping of elephant ears or plumage fluffing in birds. Taking inspiration from nature and to explore the possibilities of such heat transfer enhancements, augmentation of heat transfer rates induced

In nature, it is commonly observed that animals and birds perform movement-based thermoregulation activities to regulate their body temperatures. For example, flapping of elephant ears or plumage fluffing in birds. Taking inspiration from nature and to explore the possibilities of such heat transfer enhancements, augmentation of heat transfer rates induced by the vibration of solid and well as novel flexible pinned heatsinks were studied in this research project. Enhancement of natural convection has always been very important in improving the performance of the cooling mechanisms. In this research, flexible heatsinks were developed and they were characterized based on natural convection cooling with moderately vibrating conditions. The vibration of heated surfaces such as motor surfaces, condenser surfaces, robotic arms and exoskeletons led to the motivation of the development of heat sinks having flexible fins with an improved heat transfer capacity. The performance of an inflexible, solid copper pin fin heat sink was considered as the baseline, current industry standard for the thermal performance. It is expected to obtain maximum convective heat transfer at the resonance frequency of the flexible pin fins. Current experimental results with fixed input frequency and varying amplitudes indicate that the vibration provides a moderate improvement in convective heat transfer, however, the flexibility of fins had negligible effects.
ContributorsPrabhu, Saurabh (Author) / Rykaczewski, Konrad (Thesis advisor) / Phelan, Patrick (Committee member) / Wang, Robert (Committee member) / Arizona State University (Publisher)
Created2019
161473-Thumbnail Image.png
Description
Buildings release an abundance of waste heat that is left unused. Thermogalvaniccells (TGCs) can take advantage of waste heat to generate electricity with a low temperature gradient. In this dissertation, I simulated the thermal transport of TGCs containing different triply periodic minimal surface (TPMS) structures, compared it to measured values and conducted a

Buildings release an abundance of waste heat that is left unused. Thermogalvaniccells (TGCs) can take advantage of waste heat to generate electricity with a low temperature gradient. In this dissertation, I simulated the thermal transport of TGCs containing different triply periodic minimal surface (TPMS) structures, compared it to measured values and conducted a mesh convergence study to examine the viability of the computational fluid dynamics (CFD) solutions. Natural convection effects are one of the driving forces in TGCs. Using the Bousinesq approximation, I was able to capture those effects in the CFD simulations as it accounts for the density variations of the fluid. Upon simulating the TGC using the Schwarz P TPMS geometry, the cathode temperature converged as I refined the mesh and approached the measured value. As for the IWP TPMS structure, the solution converged as I refined the mesh, despite having a deviation to the measured values. This was due to the abundance of sharp regions along the walls of the TPMS that ANSYS had difficulty to accurately model. Furthermore, I simulated the TGCs using different boundary condition (BC) approximations to observe the cathode and anode temperatures as well as their overall ∆T across the cell. For the TGC containing the Schwarz P geometry, Case C (constant anode temperature BC with TPMS conduction) was the most accurate while Case D (convection BC at anode with TPMS conduction) deviated from the measured values, had the most accurate ∆T and was well within the uncertainty bounds of the measured values. Larger temperature fluctuations were seen closer to the cathode while the effects steadily decrease as the fluid approaches the anode. Moreover, the TGC containing the IWP structures presented interesting results. The main deviation was from the cathode temperatures because a higher temperature readings meant that more cells in the fluid domain were prone to diverging, thereby resulting in a higher calculated cathode temperature. Simulating the TGC with the Schwarz P geometry produced satisfactory results while the TGC using the IWP geometry deviated due to the software limitations. Finally, the effects of natural convection and TPMS on TGCs were studied and it was found that the absence of natural convection lead to a higher ∆T while the absence of TPMS resulted in a more uniform temperature distribution throughout the domain
Contributorsalweqayyan, yousef (Author) / Phelan, Patrick (Thesis advisor) / Rykaczewski, Konrad (Committee member) / Milcarek, Ryan (Committee member) / Arizona State University (Publisher)
Created2021
161465-Thumbnail Image.png
Description
The phase change process of freezing water is an important application in several fields such as ice making, food freezing technologies, pharmaceuticals etc. Due to the widespread usage of ice-related products, process improvements in this technology can potentially lead to substantial energy savings. After studying the freezing process of water,

The phase change process of freezing water is an important application in several fields such as ice making, food freezing technologies, pharmaceuticals etc. Due to the widespread usage of ice-related products, process improvements in this technology can potentially lead to substantial energy savings. After studying the freezing process of water, the supercooling phenomenon was found to occur which showed a negative effect. Therefore, ultrasound was proposed as a technique to reduce the supercooling effect and improve the heat transfer rate. An experimental study was conducted to analyze the energy expenditures in the freezing process with and without the application of ultrasound. After a set of preliminary experiments, an intermittent application of ultrasound at 10W & 3.5W power levels were found to be more effective than constant-power application, and were explored in further detail. The supercooling phenomenon was thoroughly studied through iterative experiments. It was also found that the application of ultrasound during the freezing process led to the formation of shard-like ice crystals. From the intermittent ultrasound experiments performed at 10W and 3.5W power levels, percentage energy enhancements relative to no ultrasound of 8.9% ± 12.4% and 11.9% ± 24.6% were observed, respectively.
ContributorsSubramanian, Varun (Author) / Phelan, Patrick (Thesis advisor) / Calhoun, Ronald (Committee member) / Rykaczewski, Konrad (Committee member) / Arizona State University (Publisher)
Created2021
171995-Thumbnail Image.png
Description
Spray flows are important in a myriad of practical applications including fuel injection, ink-jet printing, agricultural sprays, and industrial processes. Two-phase sprays find particular use for spot cooling applications with high heat fluxes as in casting processes and power electronics. Computability of sprays in a cost-effective manner provides a path

Spray flows are important in a myriad of practical applications including fuel injection, ink-jet printing, agricultural sprays, and industrial processes. Two-phase sprays find particular use for spot cooling applications with high heat fluxes as in casting processes and power electronics. Computability of sprays in a cost-effective manner provides a path to optimize the design of nozzles to tune the spray characteristics for the needs of a particular application. Significant research has so far been devoted to understand and characterize spray flows better, be it from a theoretical, experimental or computational standpoint. The current thesis discusses a methodology for modeling primary atomization using the Quadratic Formula which is derived from an integral formulation of the governing equations. The framework is then applied to different examples of flat-fan hydraulic sprays. For each case, the spray is first resolved as a continuous fluid using the volume of fluid method. Atomization criterion is then applied to the velocity flow-field to determine the sites for primary atomization. At each site, local diameters for particle injection is determined using the quadratic formula. The trajectory of injected particles are then monitored through a particle tracking algorithm. The results from the numerical analysis are compared with experimental data to validate the computational framework.
ContributorsBhardwaj, Angshuman (Author) / Lee, T.-W. (Thesis advisor) / Herrmann, Marcus (Committee member) / Rykaczewski, Konrad (Committee member) / Arizona State University (Publisher)