Matching Items (9)
Filtering by

Clear all filters

151634-Thumbnail Image.png
Description
Two groups of cochlear implant (CI) listeners were tested for sound source localization and for speech recognition in complex listening environments. One group (n=11) wore bilateral CIs and, potentially, had access to interaural level difference (ILD) cues, but not interaural timing difference (ITD) cues. The second group (n=12) wore a

Two groups of cochlear implant (CI) listeners were tested for sound source localization and for speech recognition in complex listening environments. One group (n=11) wore bilateral CIs and, potentially, had access to interaural level difference (ILD) cues, but not interaural timing difference (ITD) cues. The second group (n=12) wore a single CI and had low-frequency, acoustic hearing in both the ear contralateral to the CI and in the implanted ear. These `hearing preservation' listeners, potentially, had access to ITD cues but not to ILD cues. At issue in this dissertation was the value of the two types of information about sound sources, ITDs and ILDs, for localization and for speech perception when speech and noise sources were separated in space. For Experiment 1, normal hearing (NH) listeners and the two groups of CI listeners were tested for sound source localization using a 13 loudspeaker array. For the NH listeners, the mean RMS error for localization was 7 degrees, for the bilateral CI listeners, 20 degrees, and for the hearing preservation listeners, 23 degrees. The scores for the two CI groups did not differ significantly. Thus, both CI groups showed equivalent, but poorer than normal, localization. This outcome using the filtered noise bands for the normal hearing listeners, suggests ILD and ITD cues can support equivalent levels of localization. For Experiment 2, the two groups of CI listeners were tested for speech recognition in noise when the noise sources and targets were spatially separated in a simulated `restaurant' environment and in two versions of a `cocktail party' environment. At issue was whether either CI group would show benefits from binaural hearing, i.e., better performance when the noise and targets were separated in space. Neither of the CI groups showed spatial release from masking. However, both groups showed a significant binaural advantage (a combination of squelch and summation), which also maintained separation of the target and noise, indicating the presence of some binaural processing or `unmasking' of speech in noise. Finally, localization ability in Experiment 1 was not correlated with binaural advantage in Experiment 2.
ContributorsLoiselle, Louise (Author) / Dorman, Michael F. (Thesis advisor) / Yost, William A. (Thesis advisor) / Azuma, Tamiko (Committee member) / Liss, Julie (Committee member) / Arizona State University (Publisher)
Created2013
153419-Thumbnail Image.png
Description
A multitude of individuals across the globe suffer from hearing loss and that number continues to grow. Cochlear implants, while having limitations, provide electrical input for users enabling them to "hear" and more fully interact socially with their environment. There has been a clinical shift to the

A multitude of individuals across the globe suffer from hearing loss and that number continues to grow. Cochlear implants, while having limitations, provide electrical input for users enabling them to "hear" and more fully interact socially with their environment. There has been a clinical shift to the bilateral placement of implants in both ears and to bimodal placement of a hearing aid in the contralateral ear if residual hearing is present. However, there is potentially more to subsequent speech perception for bilateral and bimodal cochlear implant users than the electric and acoustic input being received via these modalities. For normal listeners vision plays a role and Rosenblum (2005) points out it is a key feature of an integrated perceptual process. Logically, cochlear implant users should also benefit from integrated visual input. The question is how exactly does vision provide benefit to bilateral and bimodal users. Eight (8) bilateral and 5 bimodal participants received randomized experimental phrases previously generated by Liss et al. (1998) in auditory and audiovisual conditions. The participants recorded their perception of the input. Data were consequently analyzed for percent words correct, consonant errors, and lexical boundary error types. Overall, vision was found to improve speech perception for bilateral and bimodal cochlear implant participants. Each group experienced a significant increase in percent words correct when visual input was added. With vision bilateral participants reduced consonant place errors and demonstrated increased use of syllabic stress cues used in lexical segmentation. Therefore, results suggest vision might provide perceptual benefits for bilateral cochlear implant users by granting access to place information and by augmenting cues for syllabic stress in the absence of acoustic input. On the other hand vision did not provide the bimodal participants significantly increased access to place and stress cues. Therefore the exact mechanism by which bimodal implant users improved speech perception with the addition of vision is unknown. These results point to the complexities of audiovisual integration during speech perception and the need for continued research regarding the benefit vision provides to bilateral and bimodal cochlear implant users.
ContributorsLudwig, Cimarron (Author) / Liss, Julie (Thesis advisor) / Dorman, Michael (Committee member) / Azuma, Tamiko (Committee member) / Arizona State University (Publisher)
Created2015
153415-Thumbnail Image.png
Description
In the noise and commotion of daily life, people achieve effective communication partly because spoken messages are replete with redundant information. Listeners exploit available contextual, linguistic, phonemic, and prosodic cues to decipher degraded speech. When other cues are absent or ambiguous, phonemic and prosodic cues are particularly important

In the noise and commotion of daily life, people achieve effective communication partly because spoken messages are replete with redundant information. Listeners exploit available contextual, linguistic, phonemic, and prosodic cues to decipher degraded speech. When other cues are absent or ambiguous, phonemic and prosodic cues are particularly important because they help identify word boundaries, a process known as lexical segmentation. Individuals vary in the degree to which they rely on phonemic or prosodic cues for lexical segmentation in degraded conditions.

Deafened individuals who use a cochlear implant have diminished access to fine frequency information in the speech signal, and show resulting difficulty perceiving phonemic and prosodic cues. Auditory training on phonemic elements improves word recognition for some listeners. Little is known, however, about the potential benefits of prosodic training, or the degree to which individual differences in cue use affect outcomes.

The present study used simulated cochlear implant stimulation to examine the effects of phonemic and prosodic training on lexical segmentation. Participants completed targeted training with either phonemic or prosodic cues, and received passive exposure to the non-targeted cue. Results show that acuity to the targeted cue improved after training. In addition, both targeted attention and passive exposure to prosodic features led to increased use of these cues for lexical segmentation. Individual differences in degree and source of benefit point to the importance of personalizing clinical intervention to increase flexible use of a range of perceptual strategies for understanding speech.
ContributorsHelms Tillery, Augusta Katherine (Author) / Liss, Julie M. (Thesis advisor) / Azuma, Tamiko (Committee member) / Brown, Christopher A. (Committee member) / Dorman, Michael F. (Committee member) / Utianski, Rene L. (Committee member) / Arizona State University (Publisher)
Created2015
150688-Thumbnail Image.png
Description
Otoacoustic emissions (OAEs) are soft sounds generated by the inner ear and can be recorded within the ear canal. Since OAEs can reflect the functional status of the inner ear, OAE measurements have been widely used for hearing loss screening in the clinic. However, there are limitations in current clinical

Otoacoustic emissions (OAEs) are soft sounds generated by the inner ear and can be recorded within the ear canal. Since OAEs can reflect the functional status of the inner ear, OAE measurements have been widely used for hearing loss screening in the clinic. However, there are limitations in current clinical OAE measurements, such as the restricted frequency range, low efficiency and inaccurate calibration. In this dissertation project, a new method of OAE measurement which used a swept tone to evoke the stimulus frequency OAEs (SFOAEs) was developed to overcome the limitations of current methods. In addition, an in-situ calibration was applied to equalize the spectral level of the swept-tone stimulus at the tympanic membrane (TM). With this method, SFOAEs could be recorded with high resolution over a wide frequency range within one or two minutes. Two experiments were conducted to verify the accuracy of the in-situ calibration and to test the performance of the swept-tone SFOAEs. In experiment I, the calibration of the TM sound pressure was verified in both acoustic cavities and real ears by using a second probe microphone. In addition, the benefits of the in-situ calibration were investigated by measuring OAEs under different calibration conditions. Results showed that the TM pressure could be predicted correctly, and the in-situ calibration provided the most reliable results in OAE measurements. In experiment II, a three-interval paradigm with a tracking-filter technique was used to record the swept-tone SFOAEs in 20 normal-hearing subjects. The test-retest reliability of the swept-tone SFOAEs was examined using a repeated-measure design under various stimulus levels and durations. The accuracy of the swept-tone method was evaluated by comparisons with a standard method using discrete pure tones. Results showed that SFOAEs could be reliably and accurately measured with the swept-tone method. Comparing with the pure-tone approach, the swept-tone method showed significantly improved efficiency. The swept-tone SFOAEs with in-situ calibration may be an alternative of current clinical OAE measurements for more detailed evaluation of inner ear function and accurate diagnosis.
ContributorsChen, Shixiong (Author) / Bian, Lin (Thesis advisor) / Yost, William (Committee member) / Azuma, Tamiko (Committee member) / Dorman, Michael (Committee member) / Arizona State University (Publisher)
Created2012
136164-Thumbnail Image.png
Description
The increase of Traumatic Brain Injury (TBI) cases in recent war history has increased the urgency of research regarding how veterans are affected by TBIs. The purpose of this study was to evaluate the effects of TBI on speech recognition in noise. The AzBio Sentence Test was completed for signal-to-noise

The increase of Traumatic Brain Injury (TBI) cases in recent war history has increased the urgency of research regarding how veterans are affected by TBIs. The purpose of this study was to evaluate the effects of TBI on speech recognition in noise. The AzBio Sentence Test was completed for signal-to-noise ratios (S/N) from -10 dB to +15 dB for a control group of ten participants and one US military veteran with history of service-connected TBI. All participants had normal hearing sensitivity defined as thresholds of 20 dB or better at frequencies from 250-8000 Hz in addition to having tympanograms within normal limits. Comparison of the data collected on the control group versus the veteran suggested that the veteran performed worse than the majority of the control group on the AzBio Sentence Test. Further research with more participants would be beneficial to our understanding of how veterans with TBI perform on speech recognition tests in the presence of background noise.
ContributorsCorvasce, Erica Marie (Author) / Peterson, Kathleen (Thesis director) / Williams, Erica (Committee member) / Azuma, Tamiko (Committee member) / Barrett, The Honors College (Contributor) / Department of Speech and Hearing Science (Contributor)
Created2015-05
133858-Thumbnail Image.png
Description
Working memory and cognitive functions contribute to speech recognition in normal hearing and hearing impaired listeners. In this study, auditory and cognitive functions are measured in young adult normal hearing, elderly normal hearing, and elderly cochlear implant subjects. The effects of age and hearing on the different measures are investigated.

Working memory and cognitive functions contribute to speech recognition in normal hearing and hearing impaired listeners. In this study, auditory and cognitive functions are measured in young adult normal hearing, elderly normal hearing, and elderly cochlear implant subjects. The effects of age and hearing on the different measures are investigated. The correlations between auditory/cognitive functions and speech/music recognition are examined. The results may demonstrate which factors can better explain the variable performance across elderly cochlear implant users.
ContributorsKolberg, Courtney Elizabeth (Author) / Luo, Xin (Thesis director) / Azuma, Tamiko (Committee member) / Department of Speech and Hearing Science (Contributor) / Barrett, The Honors College (Contributor)
Created2018-05
134779-Thumbnail Image.png
Description
Pitch and timbre perception are two important dimensions of auditory perception. These aspects of sound aid the understanding of our environment, and contribute to normal everyday functioning. It is therefore important to determine the nature of perceptual interaction between these two dimensions of sound. This study tested the interactions between

Pitch and timbre perception are two important dimensions of auditory perception. These aspects of sound aid the understanding of our environment, and contribute to normal everyday functioning. It is therefore important to determine the nature of perceptual interaction between these two dimensions of sound. This study tested the interactions between pitch perception associated with the fundamental frequency (F0) and sharpness perception associated with the spectral slope of harmonic complex tones in normal hearing (NH) listeners and cochlear implant (CI) users. Pitch and sharpness ranking was measured without changes in the non-target dimension (Experiment 1), with different amounts of unrelated changes in the non-target dimension (Experiment 2), and with congruent/incongruent changes of similar perceptual salience in the non-target dimension (Experiment 3). The results showed that CI users had significantly worse pitch and sharpness ranking thresholds than NH listeners. Pitch and sharpness perception had symmetric interactions in NH listeners. However, for CI users, spectral slope changes significantly affected pitch ranking, while F0 changes had no significant effect on sharpness ranking. CI users' pitch ranking sensitivity was significantly better with congruent than with incongruent spectral slope changes. These results have important implications for CI processing strategies to better transmit pitch and timbre cues to CI users.
ContributorsSoslowsky, Samara Miranda (Author) / Luo, Xin (Thesis director) / Yost, William (Committee member) / Dorman, Michael (Committee member) / Department of Speech and Hearing Science (Contributor) / Barrett, The Honors College (Contributor)
Created2016-12
137669-Thumbnail Image.png
Description
When listeners hear sentences presented simultaneously, the listeners are better able to discriminate between speakers when there is a difference in fundamental frequency (F0). This paper explores the use of a pulse train vocoder to simulate cochlear implant listening. A pulse train vocoder, rather than a noise or tonal vocoder,

When listeners hear sentences presented simultaneously, the listeners are better able to discriminate between speakers when there is a difference in fundamental frequency (F0). This paper explores the use of a pulse train vocoder to simulate cochlear implant listening. A pulse train vocoder, rather than a noise or tonal vocoder, was used so the fundamental frequency (F0) of speech would be well represented. The results of this experiment showed that listeners are able to use the F0 information to aid in speaker segregation. As expected, recognition performance is the poorest when there was no difference in F0 between speakers, and listeners performed better as the difference in F0 increased. The type of errors that the listeners made was also analyzed. The results show that when an error was made in identifying the correct word from the target sentence, the response was usually (~60%) a word that was uttered in the competing sentence.
ContributorsStanley, Nicole Ernestine (Author) / Yost, William (Thesis director) / Dorman, Michael (Committee member) / Liss, Julie (Committee member) / Barrett, The Honors College (Contributor) / Department of Speech and Hearing Science (Contributor) / Hugh Downs School of Human Communication (Contributor)
Created2013-05
161435-Thumbnail Image.png
Description
This study focuses on the properties of binaural beats (BBs) compared to Monaural beats (MBs) and their steady-state response at the level of the Superior Olivary Complex (SOC). An auditory nerve stimulator was used to simulate the response of the SOC. The simulator was fed either BBs or MBs stimuli

This study focuses on the properties of binaural beats (BBs) compared to Monaural beats (MBs) and their steady-state response at the level of the Superior Olivary Complex (SOC). An auditory nerve stimulator was used to simulate the response of the SOC. The simulator was fed either BBs or MBs stimuli to compare the SOC response. This was done for different frequencies at twenty, forty, and sixty hertz for comparison of the SOC response envelopes. A correlation between the SOC response envelopes for both types of beats and the waveform resulting from adding two tones together was completed. The highest correlation for BBs was found to be forty hertz and for MBs it was sixty hertz. A Fast Fourier Transform (FFT) was also completed on the stimulus envelope and the SOC response envelopes. The FFT was able to show that within the BBs presentation the envelopes of the original stimuli showed no difference frequency. However, the difference frequency was present in the binaural SOC response envelope. For the MBs, the difference frequency was present within the stimulus and the monaural SOC response envelope.
ContributorsCrawford, Taylor Janay (Author) / Brewer, Gene (Thesis advisor) / Zhou, Yi (Committee member) / Azuma, Tamiko (Committee member) / Arizona State University (Publisher)
Created2021