The ability of cochlear implants (CI) to restore auditory function has advanced significantly in the past decade. Approximately 96,000 people in the United States benefit from these devices, which by the generation and transmission of electrical impulses, enable the brain to perceive sound. But due to the predominantly Western cochlear

The ability of cochlear implants (CI) to restore auditory function has advanced significantly in the past decade. Approximately 96,000 people in the United States benefit from these devices, which by the generation and transmission of electrical impulses, enable the brain to perceive sound. But due to the predominantly Western cochlear implant market, current CI characterization primarily focuses on improving the quality of American English. Only recently has research begun to evaluate CI performance using other languages such as Mandarin Chinese, which rely on distinct spectral characteristics not present in English. Mandarin, a tonal language utilizes four, distinct pitch patterns, which when voiced a syllable, conveys different meanings for the same word. This presents a challenge to hearing research as spectral, or frequency based information like pitch is readily acknowledged to be significantly reduced by CI processing algorithms. Thus the present study sought to identify the intelligibility differences for English and Mandarin when processed using current CI strategies. The objective of the study was to pinpoint any notable discrepancies in speech recognition, using voice-coded (vocoded) audio that simulates a CI generated stimuli. This approach allowed 12 normal hearing English speakers, and 9 normal hearing Mandarin listeners to participate in the experiment. The number of frequency channels available and the carrier type of excitation were varied in order to compare their effects on two cases of Mandarin intelligibility: Case 1) word recognition and Case 2) combined word and tone recognition. The results indicated a statistically significant difference between English and Mandarin intelligibility for Condition 1 (8Ch-Sinewave Carrier, p=0.022) given Case 1 and Condition 1 (8Ch-Sinewave Carrier, p=0.001) and Condition 3 (16Ch-Sinewave Carrier, p=0.001) given Case 2. The data suggests that the nature of the carrier type does have an effect on tonal language intelligibility and warrants further research as a design consideration for future cochlear implants.
ContributorsSchiltz, Jessica Hammitt (Author) / Berisha, Visar (Thesis director) / Frakes, David (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2015-05
132359-Thumbnail Image.png
Description
Cochlear implant (CI) successfully restores hearing sensation to profoundly deaf patients, but its
performance is limited by poor spectral resolution. Acoustic CI simulation has been widely used
in normal-­hearing (NH) listeners to study the effect of spectral resolution on speech perception,
while avoiding patient-­related confounds. It is unclear how speech production may change

Cochlear implant (CI) successfully restores hearing sensation to profoundly deaf patients, but its
performance is limited by poor spectral resolution. Acoustic CI simulation has been widely used
in normal-­hearing (NH) listeners to study the effect of spectral resolution on speech perception,
while avoiding patient-­related confounds. It is unclear how speech production may change with
the degree of spectral degradation of auditory feedback as experience by CI users. In this study,
a real-­time sinewave CI simulation was developed to provide NH subjects with auditory
feedback of different spectral resolution (1, 2, 4, and 8 channels). NH subjects were asked to
produce and identify vowels, as well as recognize sentences while listening to the real-­time CI
simulation. The results showed that sentence recognition scores with the real-­time CI simulation
improved with more channels, similar to those with the traditional off-­line CI simulation.
Perception of a vowel continuum “HEAD”-­ “HAD” was near chance with 1, 2, and 4 channels,
and greatly improved with 8 channels and full spectrum. The spectral resolution of auditory
feedback did not significantly affect any acoustic feature of vowel production (e.g., vowel space
area, mean amplitude, mean and variability of fundamental and formant frequencies). There
was no correlation between vowel production and perception. The lack of effect of auditory
feedback spectral resolution on vowel production was likely due to the limited exposure of NH
subjects to CI simulation and the limited frequency ranges covered by the sinewave carriers of
CI simulation. Future studies should investigate the effects of various CI processing parameters
on speech production using a noise-­band CI simulation.
ContributorsPerez Lustre, Sarahi (Author) / Luo, Xin (Thesis director) / Daliri, Ayoub (Committee member) / Division of Teacher Preparation (Contributor) / College of Health Solutions (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2019-05