Matching Items (4)
Filtering by

Clear all filters

153453-Thumbnail Image.png
Description
The present study describes audiovisual sentence recognition in normal hearing listeners, bimodal cochlear implant (CI) listeners and bilateral CI listeners. This study explores a new set of sentences (the AzAV sentences) that were created to have equal auditory intelligibility and equal gain from visual information.

The aims of Experiment I

The present study describes audiovisual sentence recognition in normal hearing listeners, bimodal cochlear implant (CI) listeners and bilateral CI listeners. This study explores a new set of sentences (the AzAV sentences) that were created to have equal auditory intelligibility and equal gain from visual information.

The aims of Experiment I were to (i) compare the lip reading difficulty of the AzAV sentences to that of other sentence materials, (ii) compare the speech-reading ability of CI listeners to that of normal-hearing listeners and (iii) assess the gain in speech understanding when listeners have both auditory and visual information from easy-to-lip-read and difficult-to-lip read sentences. In addition, the sentence lists were subjected to a multi-level text analysis to determine the factors that make sentences easy or difficult to speech read.

The results of Experiment I showed that (i) the AzAV sentences were relatively difficult to lip read, (ii) that CI listeners and normal-hearing listeners did not differ in lip reading ability and (iii) that sentences with low lip-reading intelligibility (10-15 % correct) provide about a 30 percentage point improvement in speech understanding when added to the acoustic stimulus, while sentences with high lip-reading intelligibility (30-60 % correct) provide about a 50 percentage point improvement in the same comparison. The multi-level text analyses showed that the familiarity of phrases in the sentences was the primary driving factor that affects the lip reading difficulty.

The aim of Experiment II was to investigate the value, when visual information is present, of bimodal hearing and bilateral cochlear implants. The results of Experiment II showed that when visual information is present, low-frequency acoustic hearing can be of value to speech understanding for patients fit with a single CI. However, when visual information was available no gain was seen from the provision of a second CI, i.e., bilateral CIs. As was the case in Experiment I, visual information provided about a 30 percentage point improvement in speech understanding.
ContributorsWang, Shuai (Author) / Dorman, Michael (Thesis advisor) / Berisha, Visar (Committee member) / Liss, Julie (Committee member) / Arizona State University (Publisher)
Created2015
153419-Thumbnail Image.png
Description
A multitude of individuals across the globe suffer from hearing loss and that number continues to grow. Cochlear implants, while having limitations, provide electrical input for users enabling them to "hear" and more fully interact socially with their environment. There has been a clinical shift to the

A multitude of individuals across the globe suffer from hearing loss and that number continues to grow. Cochlear implants, while having limitations, provide electrical input for users enabling them to "hear" and more fully interact socially with their environment. There has been a clinical shift to the bilateral placement of implants in both ears and to bimodal placement of a hearing aid in the contralateral ear if residual hearing is present. However, there is potentially more to subsequent speech perception for bilateral and bimodal cochlear implant users than the electric and acoustic input being received via these modalities. For normal listeners vision plays a role and Rosenblum (2005) points out it is a key feature of an integrated perceptual process. Logically, cochlear implant users should also benefit from integrated visual input. The question is how exactly does vision provide benefit to bilateral and bimodal users. Eight (8) bilateral and 5 bimodal participants received randomized experimental phrases previously generated by Liss et al. (1998) in auditory and audiovisual conditions. The participants recorded their perception of the input. Data were consequently analyzed for percent words correct, consonant errors, and lexical boundary error types. Overall, vision was found to improve speech perception for bilateral and bimodal cochlear implant participants. Each group experienced a significant increase in percent words correct when visual input was added. With vision bilateral participants reduced consonant place errors and demonstrated increased use of syllabic stress cues used in lexical segmentation. Therefore, results suggest vision might provide perceptual benefits for bilateral cochlear implant users by granting access to place information and by augmenting cues for syllabic stress in the absence of acoustic input. On the other hand vision did not provide the bimodal participants significantly increased access to place and stress cues. Therefore the exact mechanism by which bimodal implant users improved speech perception with the addition of vision is unknown. These results point to the complexities of audiovisual integration during speech perception and the need for continued research regarding the benefit vision provides to bilateral and bimodal cochlear implant users.
ContributorsLudwig, Cimarron (Author) / Liss, Julie (Thesis advisor) / Dorman, Michael (Committee member) / Azuma, Tamiko (Committee member) / Arizona State University (Publisher)
Created2015
133028-Thumbnail Image.png
Description
Previous studies have found that the detection of near-threshold stimuli is decreased immediately before movement and throughout movement production. This has been suggested to occur through the use of the internal forward model processing an efferent copy of the motor command and creating a prediction that is used to cancel

Previous studies have found that the detection of near-threshold stimuli is decreased immediately before movement and throughout movement production. This has been suggested to occur through the use of the internal forward model processing an efferent copy of the motor command and creating a prediction that is used to cancel out the resulting sensory feedback. Currently, there are no published accounts of the perception of tactile signals for motor tasks and contexts related to the lips during both speech planning and production. In this study, we measured the responsiveness of the somatosensory system during speech planning using light electrical stimulation below the lower lip by comparing perception during mixed speaking and silent reading conditions. Participants were asked to judge whether a constant near-threshold electrical stimulation (subject-specific intensity, 85% detected at rest) was present during different time points relative to an initial visual cue. In the speaking condition, participants overtly produced target words shown on a computer monitor. In the reading condition, participants read the same target words silently to themselves without any movement or sound. We found that detection of the stimulus was attenuated during speaking conditions while remaining at a constant level close to the perceptual threshold throughout the silent reading condition. Perceptual modulation was most intense during speech production and showed some attenuation just prior to speech production during the planning period of speech. This demonstrates that there is a significant decrease in the responsiveness of the somatosensory system during speech production as well as milliseconds before speech is even produced which has implications for speech disorders such as stuttering and schizophrenia with pronounced deficits in the somatosensory system.
ContributorsMcguffin, Brianna Jean (Author) / Daliri, Ayoub (Thesis director) / Liss, Julie (Committee member) / Department of Psychology (Contributor) / School of Life Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2019-05
132359-Thumbnail Image.png
Description
Cochlear implant (CI) successfully restores hearing sensation to profoundly deaf patients, but its
performance is limited by poor spectral resolution. Acoustic CI simulation has been widely used
in normal-­hearing (NH) listeners to study the effect of spectral resolution on speech perception,
while avoiding patient-­related confounds. It is unclear how speech production may change

Cochlear implant (CI) successfully restores hearing sensation to profoundly deaf patients, but its
performance is limited by poor spectral resolution. Acoustic CI simulation has been widely used
in normal-­hearing (NH) listeners to study the effect of spectral resolution on speech perception,
while avoiding patient-­related confounds. It is unclear how speech production may change with
the degree of spectral degradation of auditory feedback as experience by CI users. In this study,
a real-­time sinewave CI simulation was developed to provide NH subjects with auditory
feedback of different spectral resolution (1, 2, 4, and 8 channels). NH subjects were asked to
produce and identify vowels, as well as recognize sentences while listening to the real-­time CI
simulation. The results showed that sentence recognition scores with the real-­time CI simulation
improved with more channels, similar to those with the traditional off-­line CI simulation.
Perception of a vowel continuum “HEAD”-­ “HAD” was near chance with 1, 2, and 4 channels,
and greatly improved with 8 channels and full spectrum. The spectral resolution of auditory
feedback did not significantly affect any acoustic feature of vowel production (e.g., vowel space
area, mean amplitude, mean and variability of fundamental and formant frequencies). There
was no correlation between vowel production and perception. The lack of effect of auditory
feedback spectral resolution on vowel production was likely due to the limited exposure of NH
subjects to CI simulation and the limited frequency ranges covered by the sinewave carriers of
CI simulation. Future studies should investigate the effects of various CI processing parameters
on speech production using a noise-­band CI simulation.
ContributorsPerez Lustre, Sarahi (Author) / Luo, Xin (Thesis director) / Daliri, Ayoub (Committee member) / Division of Teacher Preparation (Contributor) / College of Health Solutions (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2019-05