Matching Items (3)
Filtering by

Clear all filters

151112-Thumbnail Image.png
Description
The Arizona State University Herbarium began in 1896 when Professor Fredrick Irish collected the first recorded Arizona specimen for what was then called the Tempe Normal School - a Parkinsonia microphylla. Since then, the collection has grown to approximately 400,000 specimens of vascular plants and lichens. The most recent project

The Arizona State University Herbarium began in 1896 when Professor Fredrick Irish collected the first recorded Arizona specimen for what was then called the Tempe Normal School - a Parkinsonia microphylla. Since then, the collection has grown to approximately 400,000 specimens of vascular plants and lichens. The most recent project includes the digitization - both the imaging and databasing - of approximately 55,000 vascular plant specimens from Latin America. To accomplish this efficiently, possibilities in non-traditional methods, including both new and existing technologies, were explored. SALIX (semi-automatic label information extraction) was developed as the central tool to handle automatic parsing, along with BarcodeRenamer (BCR) to automate image file renaming by barcode. These two developments, combined with existing technologies, make up the SALIX Method. The SALIX Method provides a way to digitize herbarium specimens more efficiently than the traditional approach of entering data solely through keystroking. Using digital imaging, optical character recognition, and automatic parsing, I found that the SALIX Method processes data at an average rate that is 30% faster than typing. Data entry speed is dependent on user proficiency, label quality, and to a lesser degree, label length. This method is used to capture full specimen records, including close-up images where applicable. Access to biodiversity data is limited by the time and resources required to digitize, but I have found that it is possible to do so at a rate that is faster than typing. Finally, I experiment with the use of digital field guides in advancing access to biodiversity data, to stimulate public engagement in natural history collections.
ContributorsBarber, Anne Christine (Author) / Landrum, Leslie R. (Thesis advisor) / Wojciechowski, Martin F. (Thesis advisor) / Gilbert, Edward (Committee member) / Lafferty, Daryl (Committee member) / Arizona State University (Publisher)
Created2012
157900-Thumbnail Image.png
Description
Readout Integrated Circuits(ROICs) are important components of infrared(IR) imag

ing systems. Performance of ROICs affect the quality of images obtained from IR

imaging systems. Contemporary infrared imaging applications demand ROICs that

can support large dynamic range, high frame rate, high output data rate, at low

cost, size and power. Some of these applications are

Readout Integrated Circuits(ROICs) are important components of infrared(IR) imag

ing systems. Performance of ROICs affect the quality of images obtained from IR

imaging systems. Contemporary infrared imaging applications demand ROICs that

can support large dynamic range, high frame rate, high output data rate, at low

cost, size and power. Some of these applications are military surveillance, remote

sensing in space and earth science missions and medical diagnosis. This work focuses

on developing a ROIC unit cell prototype for National Aeronautics and Space Ad

ministration(NASA), Jet Propulsion Laboratory’s(JPL’s) space applications. These

space applications also demand high sensitivity, longer integration times(large well

capacity), wide operating temperature range, wide input current range and immunity

to radiation events such as Single Event Latchup(SEL).

This work proposes a digital ROIC(DROIC) unit cell prototype of 30ux30u size,

to be used mainly with NASA JPL’s High Operating Temperature Barrier Infrared

Detectors(HOT BIRDs). Current state of the art DROICs achieve a dynamic range

of 16 bits using advanced 65-90nm CMOS processes which adds a lot of cost overhead.

The DROIC pixel proposed in this work uses a low cost 180nm CMOS process and

supports a dynamic range of 20 bits operating at a low frame rate of 100 frames per

second(fps), and a dynamic range of 12 bits operating at a high frame rate of 5kfps.

The total electron well capacity of this DROIC pixel is 1.27 billion electrons, enabling

integration times as long as 10ms, to achieve better dynamic range. The DROIC unit

cell uses an in-pixel 12-bit coarse ADC and an external 8-bit DAC based fine ADC.

The proposed DROIC uses layout techniques that make it immune to radiation up to

300krad(Si) of total ionizing dose(TID) and single event latch-up(SEL). It also has a

wide input current range from 10pA to 1uA and supports detectors operating from

Short-wave infrared (SWIR) to longwave infrared (LWIR) regions.
ContributorsPraveen, Subramanya Chilukuri (Author) / Bakkaloglu, Bertan (Thesis advisor) / Kitchen, Jennifer (Committee member) / Long, Yu (Committee member) / Arizona State University (Publisher)
Created2019
132174-Thumbnail Image.png
Description
The NASA Psyche Iron Meteorite Imaging System (IMIS) is a standalone system created to image metal meteorites from ASU’s Center for Meteorite Studies’ collection that have an etched surface. Meteorite scientists have difficulty obtaining true-to-life images of meteorites through traditional photography methods due to the meteorites’ shiny, irregular surfaces, which

The NASA Psyche Iron Meteorite Imaging System (IMIS) is a standalone system created to image metal meteorites from ASU’s Center for Meteorite Studies’ collection that have an etched surface. Meteorite scientists have difficulty obtaining true-to-life images of meteorites through traditional photography methods due to the meteorites’ shiny, irregular surfaces, which interferes with their ability to identify meteorites’ component materials through image analysis. Using the IMIS, scientists can easily and consistently obtain glare-free photographs of meteorite surface that are suitable for future use in an artificial intelligence-based meteorite component analysis system. The IMIS integrates a lighting system, a mounted camera, a sample positioning area, a meteorite leveling/positioning system, and a touch screen control panel featuring an interface that allows the user to see a preview of the image to be taken as well as an edge detection view, a glare detection view, a button that allows the user to remotely take the picture, and feedback if very high levels of glare are detected that may indicate a camera or positioning error. Initial research and design work were completed by the end of Fall semester, and Spring semester consisted of building and testing the system. The current system is fully functional, and photos taken by the current system have been approved by a meteorite expert and an AI expert. The funding for this project was tentatively capped at $1000 for miscellaneous expenses, not including a camera to be supplied by the School of Earth and Space Exploration. When SESE was unable to provide a camera, an additional $4000 were allotted for camera expenses. So far, $1935 of the total $5000 budget has been spent on the project, putting the project $3065 under budget. While this system is a functional prototype, future capstone projects may involve the help of industrial designers to improve the technician’s experience through automating the sample positioning process.
ContributorsBaerwaldt, Morgan Kathleen (Author) / Bowman, Cassie (Thesis director) / Kozicki, Michael (Committee member) / School of Art (Contributor) / Electrical Engineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2019-05