Matching Items (7)
Filtering by

Clear all filters

154177-Thumbnail Image.png
Description
Efficient separation techniques for organelles and bacteria in the micron- and sub-micron range are required for various analytical challenges. Mitochondria have a wide size range resulting from the sub-populations, some of which may be associated with diseases or aging. However, traditional methods can often not resolve within-species size variations. Strategies

Efficient separation techniques for organelles and bacteria in the micron- and sub-micron range are required for various analytical challenges. Mitochondria have a wide size range resulting from the sub-populations, some of which may be associated with diseases or aging. However, traditional methods can often not resolve within-species size variations. Strategies to separate mitochondrial sub-populations by size are thus needed to study the importance of this organelle in cellular functions. Additionally, challenges also exist in distinguishing the sub-populations of bio-species which differ in the surface charge while possessing similar size, such as Salmonella typhimurium (Salmonella). The surface charge of Salmonella wild-type is altered upon environmental stimulations, influencing the bacterial survival and virulence within the host tissue. Therefore, it is important to explore methods to identify the sub-populations of Salmonella.

This work exploits insulator-based dielectrophoresis (iDEP) for the manipulation of mitochondria and Salmonella. The iDEP migration and trapping of mitochondria were investigated under both DC and low-frequency AC conditions, establishing that mitochondria exhibit negative DEP. Also, the first realization of size-based iDEP sorting experiments of mitochondria were demonstrated. As for Salmonella, the preliminary study revealed positive DEP behavior. Distinct trapping potential thresholds were found for the sub-populations with different surface charges.

Further, DEP was integrated with a non-intuitive migration mechanism termed absolute negative mobility (ANM), inducing a deterministic trapping component which allows the directed transport of µm- and sub-µm sized (bio)particles in microfluidic devices with a nonlinear post array under the periodic action of electrokinetic and dielectrophoretic forces. Regimes were revealed both numerically and experimentally in which larger particles migrate against the average applied force, whereas smaller particles show normal response. Moreover, this deterministic ANM (dANM) was characterized with polystyrene beads demonstrating improved migration speed at least two orders of magnitude higher compared to previous ANM systems with similar sized colloids. In addition, dANM was induced for mitochondria with an AC-overlaid waveform representing the first demonstration of ANM migration with biological species. Thus, it is envisioned that the efficient size selectivity of this novel migration mechanism can be employed in nanotechnology, organelle sub-population studies or fractionating protein nanocrystals.
ContributorsLuo, Jinghui (Author) / Ros, Alexandra (Thesis advisor) / Hayes, Mark (Committee member) / Borges, Chad (Committee member) / Arizona State University (Publisher)
Created2015
157302-Thumbnail Image.png
Description
Dielectrophoresis (DEP) is a technique that influences the motion of polarizable particles in an electric field gradient. DEP can be combined with other effects that influence the motion of a particle in a microchannel, such as electrophoresis and electroosmosis. Together, these three can be used to probe properties

Dielectrophoresis (DEP) is a technique that influences the motion of polarizable particles in an electric field gradient. DEP can be combined with other effects that influence the motion of a particle in a microchannel, such as electrophoresis and electroosmosis. Together, these three can be used to probe properties of an analyte, including charge, conductivity, and zeta potential. DEP shows promise as a high-resolution differentiation and separation method, with the ability to distinguish between subtly-different populations. This, combined with the fast (on the order of minutes) analysis times offered by the technique, lend it many of the features necessary to be used in rapid diagnostics and point-of-care devices.

Here, a mathematical model of dielectrophoretic data is presented to connect analyte properties with data features, including the intercept and slope, enabling DEP to be used in applications which require this information. The promise of DEP to distinguish between analytes with small differences is illustrated with antibiotic resistant bacteria. The DEP system is shown to differentiate between methicillin-resistant and susceptible Staphylococcus aureus. This differentiation was achieved both label free and with bacteria that had been fluorescently-labeled. Klebsiella pneumoniae carbapenemase-positive and negative Klebsiella pneumoniae were also distinguished, demonstrating the differentiation for a different mechanism of antibiotic resistance. Differences in dielectrophoretic behavior as displayed by S. aureus and K. pneumoniae were also shown by Staphylococcus epidermidis. These differences were exploited for a separation in space of gentamicin-resistant and -susceptible S. epidermidis. Besides establishing the ability of DEP to distinguish between populations with small biophysical differences, these studies illustrate the possibility for the use of DEP in applications such as rapid diagnostics.
ContributorsHilton, Shannon (Author) / Hayes, Mark A. (Thesis advisor) / Borges, Chad (Committee member) / Herckes, Pierre (Committee member) / Arizona State University (Publisher)
Created2019
135861-Thumbnail Image.png
Description
Dielectrophoresis is a separations strategy that has the potential to separate small amounts of different proteins from each other. The forces at play in the channel used for dielectrophoresis are electroosmotic flow (EOF), electrophoresis (EP), and dielectrophoresis (DEP). EOF is the force exerted on liquid from an applied potential (1).

Dielectrophoresis is a separations strategy that has the potential to separate small amounts of different proteins from each other. The forces at play in the channel used for dielectrophoresis are electroosmotic flow (EOF), electrophoresis (EP), and dielectrophoresis (DEP). EOF is the force exerted on liquid from an applied potential (1). EP is the force exerted on charged particles in a uniform electric field (2). DEP is the force exerted on particles (charged and uncharged) in a non-uniform electric field (3). This experiment was focused on the testing of a new microfluidic device to see if it could improve the focusing of proteins in dielectrophoresis. It was predicted that the addition of a salt bridge would improve focusing by preventing the ions created by the electrolysis of water around the electrodes from interacting with the proteins and causing aggregation, among other problems. Control trials using the old device showed that electrolysis was likely occurring and was the causal agent for poor outcomes. After applying the electric potential for some time a pH front traveled through the channel causing aggregation of proteins and the current in the channel decreased rapidly, even while the voltage was held constant. The resistance in the channels of the control trials also slightly decreased over time, until the pH shift occurred, at which time it increased rapidly. Experimental trials with a new device that included salt bridges eliminated this pH front and had a roughly linear increase of current in the channel with the voltage applied. This device can now be used in future research with protein dielectrophoresis, including in the potential differentiation of different proteins. References: 1) Electroosmosis. Oxford Dictionary of Biochemistry and Molecular Biology. 2. Oxford University Press: Oxford, England. 2006. 2) Electrophoresis. Oxford Dictionary of Biochemistry and Molecular Biology. 2. Oxford University Press: Oxford, England. 2006. 3) Dielectrophoresis. Oxford Dictionary of Biochemistry and Molecular Biology. 2. Oxford University Press: Oxford, England. 2006.
ContributorsHayes, Katelyn Donna (Author) / Hayes, Mark (Thesis director) / Borges, Chad (Committee member) / School of Life Sciences (Contributor) / Department of Psychology (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
Description

There are limited methods and techniques to quantitatively assess protein content in single cells or small cell populations of tissues. The standard protein insulin was used to understand how potential changes in the preparation or co-crystallization process could improve sensitivity and limit of detection through matrix assisted laser desorption ionization

There are limited methods and techniques to quantitatively assess protein content in single cells or small cell populations of tissues. The standard protein insulin was used to understand how potential changes in the preparation or co-crystallization process could improve sensitivity and limit of detection through matrix assisted laser desorption ionization (MALDI) mass spectrometry analysis in Bruker’s Microflex LRF using polydimethylsiloxane (PDMS) reservoirs. In addition, initial imaging tests were performed on Bruker’s RapifleX MALDI Tissuetyper to determine the instrument’s imaging capabilities on proteins of interest through the use of a single layer “Christmas tree” microfluidic device, with the aim of applying a similar approach to future tissue samples. Data on 2µM insulin determined that a 95% laser power in the Microflex corresponded to 12-15% laser power in the RapifleX. Based on the experiments with insulin, the process of mixing insulin and saturated ɑ-Cyano-4-hydroxycinnamic acid (HCCA) matrix solvent in a 1:1 ratio using 10mM sodium phosphate buffer under area analysis is most optimized with a limit of detection value of 110 nM. With this information, the future aim is to apply this method to a double layer Christmas tree device in order to hopefully quantitatively analyze and image protein content in single or small cell populations.

ContributorsKow, Keegan (Author) / Ros, Alexandra (Thesis director) / Borges, Chad (Committee member) / Cruz-Villarreal, Jorvani (Committee member) / Barrett, The Honors College (Contributor) / School of Molecular Sciences (Contributor)
Created2023-05
168413-Thumbnail Image.png
Description
Microfluidic platforms have been exploited extensively as a tool for the separation of particles by electric field manipulation. Microfluidic devices can facilitate the manipulation of particles by dielectrophoresis. Separation of particles by size and type has been demonstrated by insulator-based dielectrophoresis in a microfluidic device. Thus, manipulating particles by size

Microfluidic platforms have been exploited extensively as a tool for the separation of particles by electric field manipulation. Microfluidic devices can facilitate the manipulation of particles by dielectrophoresis. Separation of particles by size and type has been demonstrated by insulator-based dielectrophoresis in a microfluidic device. Thus, manipulating particles by size has been widely studied throughout the years. It has been shown that size-heterogeneity in organelles has been linked to multiple diseases from abnormal organelle size. Here, a mixture of two sizes of polystyrene beads (0.28 and 0.87 μm) was separated by a ratchet migration mechanism under a continuous flow (20 nL/min). Furthermore, to achieve high-throughput separation, different ratchet devices were designed to achieve high-volume separation. Recently, enormous efforts have been made to manipulate small size DNA and proteins. Here, a microfluidic device comprising of multiple valves acting as insulating constrictions when a potential is applied is presented. The tunability of the electric field gradient is evaluated by a COMSOL model, indicating that high electric field gradients can be reached by deflecting the valve at a certain distance. Experimentally, the tunability of the dynamic constriction was demonstrated by conducting a pressure study to estimate the gap distance between the valve and the substrate at different applied pressures. Finally, as a proof of principle, 0.87 μm polystyrene beads were manipulated by dielectrophoresis. These microfluidic platforms will aid in the understanding of size-heterogeneity of organelles for biomolecular assessment and achieve separation of nanometer-size DNA and proteins by dielectrophoresis.
ContributorsOrtiz, Ricardo (Author) / Ros, Alexandra (Thesis advisor) / Hayes, Mark (Committee member) / Borges, Chad (Committee member) / Arizona State University (Publisher)
Created2021
158077-Thumbnail Image.png
Description
There is increasing interest and demand in biology studies for identifying and characterizing rare cells or bioparticle subtypes. These subpopulations demonstrate special function, as examples, in multipotent proliferation, immune system response, and cancer diagnosis. Current techniques for separation and identification of these targets lack the accuracy and sensitivity needed to

There is increasing interest and demand in biology studies for identifying and characterizing rare cells or bioparticle subtypes. These subpopulations demonstrate special function, as examples, in multipotent proliferation, immune system response, and cancer diagnosis. Current techniques for separation and identification of these targets lack the accuracy and sensitivity needed to interrogate the complex and diverse bioparticle mixtures. High resolution separations of unlabeled and unaltered cells is an emerging capability. In particular, electric field-driven punctuated microgradient separations have shown high resolution separations of bioparticles. These separations are based on biophysical properties of the un-altered bioparticles. Here, the properties of the bioparticles were identified by ratio of electrokinetic (EK) to dielectrophoretic (DEP) mobilities.

As part of this dissertation, high-resolution separations have been applied to neural stem and progenitor cells (NSPCs). The abundance of NSPCs captured with different range of ratio of EK to DEP mobilities are consistent with the final fate trends of the populations. This supports the idea of unbiased and unlabeled high-resolution separation of NSPCs to specific fates is possible. In addition, a new strategy to generate reproducible subpopulations using varied applied potential were employed for studying insulin vesicles from beta cells. The isolated subpopulations demonstrated that the insulin vesicles are heterogenous and showed different distribution of mobility ratios when compared with glucose treated insulin vesicles. This is consistent with existing vesicle density and local concentration data. Furthermore, proteins, which are accepted as challenging small bioparticles to be captured by electrophysical method, were concentrated by this technique. Proteins including IgG, lysozyme, alpha-chymotrypsinogen A were differentiated and characterized with the ratio factor. An extremely narrow bandwidth and high resolution characterization technique, which is experimentally simple and fast, has been developed for proteins. Finally, the native whole cell separation technique has also been applied for Salmonella serotype identification and differentiation for the first time. The technique generated full differentiation of four serotypes of Salmonella. These works may lead to a less expensive and more decentralized new tool and method for transplantation, proteomics, basic research, and microbiologists, working in parallel with other characterization methods.
ContributorsLiu, Yameng (Author) / Hayes, Mark A. (Thesis advisor) / Wang, Xu (Committee member) / Borges, Chad (Committee member) / Arizona State University (Publisher)
Created2020
158550-Thumbnail Image.png
Description
Novel electric field-assisted microfluidic platforms were developed to exploit unique migration phenomena, particle manipulation, and enhanced droplet control. The platforms can facilitate various analytical challenges such as size-based separations, and delivery of protein crystals for structural discovery with both high selectivity and sensitivity. The vast complexity of biological analytes requires

Novel electric field-assisted microfluidic platforms were developed to exploit unique migration phenomena, particle manipulation, and enhanced droplet control. The platforms can facilitate various analytical challenges such as size-based separations, and delivery of protein crystals for structural discovery with both high selectivity and sensitivity. The vast complexity of biological analytes requires efficient transport and fractionation approaches to understand variations of biomolecular processes and signatures. Size heterogeneity is one characteristic that is especially important to understand for sub-micron organelles such as mitochondria and lipid droplets. It is crucial to resolve populations of sub-cellular or diagnostically relevant bioparticles when these often cannot be resolved with traditional methods. Herein, novel microfluidic tools were developed for the unique migration mechanism capable of separating sub-micron sized bioparticles by size. This based on a deterministic ratchet effect in a symmetrical post array with dielectrophoresis (DEP) for the fast migration allowing separation of polystyrene beads, mitochondria, and liposomes in tens of seconds. This mechanism was further demonstrated using high throughput DEP-based ratchet devices for versatile, continuous sub-micron size particle separation with large sample volumes. Serial femtosecond crystallography (SFX) with X-ray free-electron lasers (XFELs) revolutionized protein structure determination. In SFX experiments, a majority of the continuously injected liquid crystal suspension is wasted due to the unique X-ray pulse structure of XFELs, requiring a large amount (up to grams) of crystal sample to determine a protein structure. To reduce the sample consumption in such experiments, 3D printed droplet-based microfluidic platforms were developed for the generation of aqueous droplets in an oil phase. The implemented droplet-based sample delivery method showed 60% less sample volume consumption compared to the continuous injection at the European XFEL. For the enhanced control of aqueous droplet generation, the device allowed dynamic triggering of droplets for further improvement in synchronization between droplets and the X-ray pulses. This innovative technique of triggering droplets can play a crucial role in saving protein crystals in future SFX experiments. The electric field-assisted unique migration and separation phenomena in microfluidic platforms will be the key solution for revolutionizing the field of organelle separation and structural analysis of proteins.
ContributorsKim, Dai Hyun (Author) / Ros, Alexandra (Thesis advisor) / Hayes, Mark (Committee member) / Borges, Chad (Committee member) / Arizona State University (Publisher)
Created2020