Matching Items (8)
Filtering by

Clear all filters

137416-Thumbnail Image.png
Description
Microfluidics is an expanding research area for analytical chemistry and the biomedical industry. Microfludic devices have been used for protein and DNA sorting, early detection techniques for cancer and other disease, and a variety of other analytical techniques. Dielectrophoresis is a technique is often used to control particles within microfluidic

Microfluidics is an expanding research area for analytical chemistry and the biomedical industry. Microfludic devices have been used for protein and DNA sorting, early detection techniques for cancer and other disease, and a variety of other analytical techniques. Dielectrophoresis is a technique is often used to control particles within microfluidic devices however the non-uniform electric field can affect the interior of the device. In order to expand the applications of microfluidic devices and to make it easier to work with techniques such as dielectrophoresis, it is essential to understand as much as possible about how the internal environment of the device will affect the sample. A significant part of this is being able to non-invasively determine the temperature inside the microfluidic device in the both the channel and reservoir regions. Several other research group have successfully used temperature sensitive dyes and fluorescence to measure the temperature within microfluidic devices so research began with understanding their techniques and trying to optimize them for the chosen microfluidic channel. Results from calibration and reservoir tests show that there is a linear relationship between the temperature of the channel and the ratio between the dyes Rhodamine 110 and Rhodamine B. Results within the channel showed that the calibration may be difficult to apply directly as absorption from the PDMS continues to be a problem but several coatings can be used to improve the results.
ContributorsBush, Kathleen (Author) / Ros, Alexandra (Thesis director) / Hayes, Mark (Committee member) / Alanis, Fernanda Camacho (Committee member) / Barrett, The Honors College (Contributor)
Created2013-12
136904-Thumbnail Image.png
Description
A major goal of the Center for Biosignatures Discovery Automation (CBDA) is to design a diagnostic tool that detects novel cancer biosignatures at the single-cell level. We designed the Single-cell QUantitative In situ Reverse Transcription-Polymerase Chain Reaction (SQUIRT-PCR) system by combining a two-photon laser lysis (2PLL) system with a

A major goal of the Center for Biosignatures Discovery Automation (CBDA) is to design a diagnostic tool that detects novel cancer biosignatures at the single-cell level. We designed the Single-cell QUantitative In situ Reverse Transcription-Polymerase Chain Reaction (SQUIRT-PCR) system by combining a two-photon laser lysis (2PLL) system with a microfluidic reverse transcriptase-quantitative polymerase chain reaction (RT-qPCR) platform. It is important to identify early molecular changes from intact tissues as prognosis for premalignant conditions and develop new molecular targets for prevention of cancer progression and improved therapies. This project analyzes RNA expression at the single-cell level and presents itself with two major challenges: (1) detecting low levels of RNA and (2) minimizing RNA absorption in the polydimethylsiloxane (PDMS) microfluidic channel. The first challenge was overcome by successfully detecting picogram (pg) levels of RNA using the Fluidigm (FD) BioMark™ HD System (Fluidigm Corporation, South San Francisco, CA) for RT-qPCR analysis. This technology incorporates a highly precise integrated fluidic circuit (IFC) that allows for high-throughput genetic screening using microarrays. The second challenge entailed collecting data from RNA flow-through samples that were passed through microfluidic channels. One channel was treated with a coating of polyethylene glycol (PEG) and the other remained untreated. Various flow-through samples were subjected to RT-qPCR and analyzed using the FD FLEXsix™ Gene Expression IFC. As predicted, the results showed that the treated PDMS channel absorbed less RNA than the untreated PDMS channel. Once the optimization of the PDMS microfluidic platform is complete, it will be implemented into the 2PLL system. This novel technology will be able to identify cell populations in situ and could have a large impact on cancer diagnostics.
ContributorsBlatt, Amy Elissa (Author) / Meldrum, Deirdre R. (Thesis director) / Tran, Thai (Committee member) / Chao, Joseph (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
133224-Thumbnail Image.png
Description
After more than 40 years since the signing of the National Cancer Act in 1970, cancer remains a formidable challenge. Cancer is currently the second most common cause of death in the United States, and worldwide cancer cases are projected to rise 50% between 2012 and 2030 [1-2]. While researchers

After more than 40 years since the signing of the National Cancer Act in 1970, cancer remains a formidable challenge. Cancer is currently the second most common cause of death in the United States, and worldwide cancer cases are projected to rise 50% between 2012 and 2030 [1-2]. While researchers have dramatically expanded our understanding of the biology of cancer, they have also revealed the staggering complexity and difficulty of developing successful treatments for the disease. More complex assays involving three dimensional cell culture offer the potential to model complex interactions, such as those involving the extracellular matrix (ECM), chemical concentration gradients, and the impact of vascularization of a tissue mass. Modern cancer assays thus promise to be both more accurate and more complex than previous models. One promising newly developed type of assay is microfluidics. Microfluidic devices consist of a silicone polymer stamp bonded to a glass slide. The stamp is patterned to produce a network of channels for cell culture. These devices allow manipulation of liquids on a sub-millimeter level, allowing researchers to produce a tightly controlled 3D microenvironment for cell culture. Our lab previously developed a microfluidic device to measure cancer cell invasion in response to a variety of signals and conditions. The small volume associated with microfluidics offers a number of advantages, but simultaneously make it impractical to use certain traditional cell analysis procedures, such as Western Blotting. As a result, measuring protein expression of cells in the microfluidic device was a continuing challenge. In order to expand the utility of microfluidic devices, it was therefore very enticing to develop a means of measuring protein expression inside the device. One possible solution was identified in the technique of In-Cell-Western blotting (ICW). ICW consists of using infrared-fluorescently stained antibodies to stain a protein of interest. This signal is measured using an infrared laser scanner, producing images that can be analyzed to quantitatively measure protein expression. ICW has been well validated in traditional 2D plate culture conditions, but has not been applied in conjunction with microfluidic devices. This project worked to evaluate In-Cell-Western blotting for use in microfluidic devices as a method of quantifying protein expression in situ.
ContributorsKratz, Alexander Franz (Author) / Nikkhah, Mehdi (Thesis director) / Truong, Danh (Committee member) / School of Life Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2018-05
135861-Thumbnail Image.png
Description
Dielectrophoresis is a separations strategy that has the potential to separate small amounts of different proteins from each other. The forces at play in the channel used for dielectrophoresis are electroosmotic flow (EOF), electrophoresis (EP), and dielectrophoresis (DEP). EOF is the force exerted on liquid from an applied potential (1).

Dielectrophoresis is a separations strategy that has the potential to separate small amounts of different proteins from each other. The forces at play in the channel used for dielectrophoresis are electroosmotic flow (EOF), electrophoresis (EP), and dielectrophoresis (DEP). EOF is the force exerted on liquid from an applied potential (1). EP is the force exerted on charged particles in a uniform electric field (2). DEP is the force exerted on particles (charged and uncharged) in a non-uniform electric field (3). This experiment was focused on the testing of a new microfluidic device to see if it could improve the focusing of proteins in dielectrophoresis. It was predicted that the addition of a salt bridge would improve focusing by preventing the ions created by the electrolysis of water around the electrodes from interacting with the proteins and causing aggregation, among other problems. Control trials using the old device showed that electrolysis was likely occurring and was the causal agent for poor outcomes. After applying the electric potential for some time a pH front traveled through the channel causing aggregation of proteins and the current in the channel decreased rapidly, even while the voltage was held constant. The resistance in the channels of the control trials also slightly decreased over time, until the pH shift occurred, at which time it increased rapidly. Experimental trials with a new device that included salt bridges eliminated this pH front and had a roughly linear increase of current in the channel with the voltage applied. This device can now be used in future research with protein dielectrophoresis, including in the potential differentiation of different proteins. References: 1) Electroosmosis. Oxford Dictionary of Biochemistry and Molecular Biology. 2. Oxford University Press: Oxford, England. 2006. 2) Electrophoresis. Oxford Dictionary of Biochemistry and Molecular Biology. 2. Oxford University Press: Oxford, England. 2006. 3) Dielectrophoresis. Oxford Dictionary of Biochemistry and Molecular Biology. 2. Oxford University Press: Oxford, England. 2006.
ContributorsHayes, Katelyn Donna (Author) / Hayes, Mark (Thesis director) / Borges, Chad (Committee member) / School of Life Sciences (Contributor) / Department of Psychology (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
147759-Thumbnail Image.png
Description

Serial femtosecond crystallography (SFX) with an X-ray free-electron laser (XFEL) has enabled the determination of protein structures and protein reaction intermediates in millisecond to microsecond time resolutions. Mix-and-Inject crystallography (MISC) at XFELs enables fast mixing in the magnitude of milliseconds in order to achieve desired reaction time points. For these

Serial femtosecond crystallography (SFX) with an X-ray free-electron laser (XFEL) has enabled the determination of protein structures and protein reaction intermediates in millisecond to microsecond time resolutions. Mix-and-Inject crystallography (MISC) at XFELs enables fast mixing in the magnitude of milliseconds in order to achieve desired reaction time points. For these experiments, numerical simulations of a hydrodynamic flow mixer capable of fast mixing by diffusion has been developed using both COMSOL Multiphysics 5.6 and QuickerSims Computational Fluid Dynamics (CFD) Toolbox for MATLAB. These simulation programs were compared by calculations of mixing times and concentration flow profiles. Mixing times in the range of 1-10 ms were calculated in COMSOL under certain flow rate conditions whereas mixing times in the range of 6-15 ms were calculated with QuickerSims. From these mixing times, reaction intermediates can be varied from sub-millisecond to several hundred millisecond time points for a MISC experiment. Explanations for the discrepancies between the two models were attributed to variations in parameter definitions and meshing. Further analysis on the mixing characteristics were investigated by calculating an analytical solution to the convection-diffusion equation for fluid flow in a two-dimensional rectangular channel. The concentration profile along the width of the channel for the analytical solution was compared with the numerical solution obtained with COMSOL and QuickerSims. Upon comparison, it was determined that the diffusion coefficient may not be a significant factor for the disagreement between the two hydrodynamic flow models.

ContributorsGuzman, Manuel Alexander (Author) / Ros, Alexandra (Thesis director) / Williams, Peter (Committee member) / Hayes, Mark (Committee member) / School of Mathematical and Statistical Sciences (Contributor) / School of Molecular Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2021-05
Description

There are limited methods and techniques to quantitatively assess protein content in single cells or small cell populations of tissues. The standard protein insulin was used to understand how potential changes in the preparation or co-crystallization process could improve sensitivity and limit of detection through matrix assisted laser desorption ionization

There are limited methods and techniques to quantitatively assess protein content in single cells or small cell populations of tissues. The standard protein insulin was used to understand how potential changes in the preparation or co-crystallization process could improve sensitivity and limit of detection through matrix assisted laser desorption ionization (MALDI) mass spectrometry analysis in Bruker’s Microflex LRF using polydimethylsiloxane (PDMS) reservoirs. In addition, initial imaging tests were performed on Bruker’s RapifleX MALDI Tissuetyper to determine the instrument’s imaging capabilities on proteins of interest through the use of a single layer “Christmas tree” microfluidic device, with the aim of applying a similar approach to future tissue samples. Data on 2µM insulin determined that a 95% laser power in the Microflex corresponded to 12-15% laser power in the RapifleX. Based on the experiments with insulin, the process of mixing insulin and saturated ɑ-Cyano-4-hydroxycinnamic acid (HCCA) matrix solvent in a 1:1 ratio using 10mM sodium phosphate buffer under area analysis is most optimized with a limit of detection value of 110 nM. With this information, the future aim is to apply this method to a double layer Christmas tree device in order to hopefully quantitatively analyze and image protein content in single or small cell populations.

ContributorsKow, Keegan (Author) / Ros, Alexandra (Thesis director) / Borges, Chad (Committee member) / Cruz-Villarreal, Jorvani (Committee member) / Barrett, The Honors College (Contributor) / School of Molecular Sciences (Contributor)
Created2023-05
Description

An electric field can be applied to a microfluidic device in order to stop particle flow. Electroosmosis, electrophoresis, and dielectrophoresis act on the particles in different directions in the microfluidic channel, and when these forces create zero net force, the particle stops in the channel. The goal of the performed

An electric field can be applied to a microfluidic device in order to stop particle flow. Electroosmosis, electrophoresis, and dielectrophoresis act on the particles in different directions in the microfluidic channel, and when these forces create zero net force, the particle stops in the channel. The goal of the performed experiments is to investigate whether hydrostatic pressure generated by a syringe pump could help concentrate these particles and separate them from other contents. Introducing precise, adjustable hydrostatic pressure from the syringe pump provides another mechanism for controlling particle behavior. A microfluidic channel was crafted into a device connected to a syringe pump, and videos of 1 µm silica particles in the device were recorded under a microscope in order to show that samples could be infused into the device and concentrated or captured at a specific location in the channel using hydrostatic pressure. Capture of the particles occurred with and without controlled hydrostatic pressure, but these events occurred somewhat consistently at different voltages. In addition, particle movement in the channel with the syringe pump off was originally attributed to the electrokinetic forces. However, when compared to experiments without the syringe pump connected to the device, it became evident that the electrokinetic forces should have moved the particles in the opposite direction and that, in actuality, there is an inherent pressure in the device also affecting particle movement even when the syringe pump is not turned on.

ContributorsRuddle, Kallen (Author) / Hayes, Mark (Thesis director) / Guo, Jia (Committee member) / Hogue, Brenda (Committee member) / Barrett, The Honors College (Contributor) / School of Molecular Sciences (Contributor)
Created2022-12
132161-Thumbnail Image.png
Description
Tumor-stroma interactions significantly influence cancer cell metastasis and disease progression. These interactions partly comprise crosstalk between tumor and stromal fibroblasts, but the key molecular mechanisms within the crosstalk governing cancer invasion are still unclear. Here we develop a 3D in vitro organotypic microfluidic to model tumor-stroma interaction by mimicking the

Tumor-stroma interactions significantly influence cancer cell metastasis and disease progression. These interactions partly comprise crosstalk between tumor and stromal fibroblasts, but the key molecular mechanisms within the crosstalk governing cancer invasion are still unclear. Here we develop a 3D in vitro organotypic microfluidic to model tumor-stroma interaction by mimicking the spatial organization of the tumor microenvironment on a chip. We co-culture breast cancer and patient-derived fibroblast cells in 3D tumor and stroma regions respectively and combine functional assessments, including cancer cell migration, with transcriptome profiling to unveil the molecular influence of tumor-stroma crosstalk on invasion. This led to the observation that cancer associated fibroblasts enhanced invasion in 3D by inducing the expression of a novel gene of interest, GPNMB, in breast cancer cells resulting in increased migration speed. Importantly, knockdown of GPNMB blunted the influence of CAFs on enhancing cancer invasion. Overall, these results demonstrate the ability of our model to recapitulate patient specific tumor microenvironment to investigate cellular and molecular consequences of tumor-stroma interactions.
ContributorsBarrientos, Eric Salvador (Author) / Nikkhah, Mehdi (Thesis director) / Veldhuizen, Jaime (Committee member) / School of Molecular Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2019-05