Matching Items (2)
Filtering by

Clear all filters

152062-Thumbnail Image.png
Description
Eccentric muscle action (ECC) occurs when the force exerted by a working muscle is less than that of an outside resistance. This is characterized by muscle lengthening, despite actin-myosin crossbridge formation. Research has indicated that muscles acting eccentrically are capable of producing more force when compared to muscles acting concentrically.

Eccentric muscle action (ECC) occurs when the force exerted by a working muscle is less than that of an outside resistance. This is characterized by muscle lengthening, despite actin-myosin crossbridge formation. Research has indicated that muscles acting eccentrically are capable of producing more force when compared to muscles acting concentrically. Further, research has shown ECC muscle actions may have different fatigue patterns that CON actions. The purpose of this study was to determine if a) ECC bench press yields greater strength than concentric (CON) as measured by one-repetition maximum (1RM), b) there is a difference between the number of repetitions that can be completed concentrically and eccentrically under the same relative intensities of 1RM (90%, 80%, 70%, 60%), c) a prediction model may be able to predict ECC 1RM from CON 1RM or CON repetitions to fatigue. For this study, 30 healthy males (age = 24.63 + 5.6 years) were tested for 1RM in CON and ECC bench press, as well as the number of repetitions they were able to complete at various intensities of mode-specific 1RM. A mechanical hoist was affixed to a gantry crane and placed over a standard weightlifting bench. The hoist was connected to 45lb plates that were loaded on a standard barbell, which allowed for mechanical raising and lowering of the barbell. For CON repetitions, the weight was mechanically lowered to the chest and the participant pressed it up. For ECC repetitions, the weight was mechanically raised and the participant lowered it. Paired t-tests showed that ECC 1RM was significantly (p < 0.05) greater than CON 1RM (ECC =255.17 + 68.37lbs, CON = 205.83 + 58.43lbs). There was a significant difference (p < 0.05) between the number of repetitions completed at 90% 1RM (CON = 4.57 + 2.21 repetitions, ECC = 7.67 + 3.24 repetitions). There were no differences in repetitions completed at any other intensity 1RM. CON 1RM and the number of repetitions completed with two different absolute loads (130-150lbs and 155-175lbs) concentrically and eccentrically were valid predictors of ECC 1RM. These data indicate that ECC actions yield increased force capabilities than CON actions, there is no difference in the rate of the fatigue, and ECC 1RM may be predicted from various CON tests.
ContributorsKelly, Stephen B., Jr (Author) / Hooker, Steven (Thesis advisor) / Brown, Lee (Committee member) / Buman, Matthew (Committee member) / Gaesser, Glenn (Committee member) / Swan, Pamela (Committee member) / Arizona State University (Publisher)
Created2013
131940-Thumbnail Image.png
Description
Estimates indicate that in the United States 1 in 8 women will develop breast cancer in their lifetime. Improved cancer screenings, early detection, and targeted treatments have increased breast cancer survival rates. However, breast cancer patients treated with chemotherapy are at an increased risk for cardiovascular disease, functional impairments, and

Estimates indicate that in the United States 1 in 8 women will develop breast cancer in their lifetime. Improved cancer screenings, early detection, and targeted treatments have increased breast cancer survival rates. However, breast cancer patients treated with chemotherapy are at an increased risk for cardiovascular disease, functional impairments, and loss of cardiorespiratory fitness. These negative outcomes have implications for early morbidity and mortality. The purpose of this thesis was to test the hypothesis that high-intensity exercise preconditioning (exercise commenced prior to initiating chemotherapy and continued throughout treatment cycles) preserves health-related outcomes in breast cancer patients treated with anthracycline-containing chemotherapy. Here, we present a subset of preliminary data from an ongoing trial (NCT02842658) that is focused on VO2peak and skeletal muscle outcomes from the first 10 participants that have enrolled in the trial. Breast cancer patients (N=10; 50 ± 11 y; 168 ± 4 cm; 92 ± 37 kg; 32.3 ± 12.3 kg/m2) scheduled to receive anthracycline-containing chemotherapy were randomly assigned to one of two interventions: 1) exercise preconditioning, (3 days per week of supervised exercise throughout treatment) or 2) standard of care (attention-control). Pre-testing occurred 1-2 week prior to chemotherapy. The interventions were initiated 1 week prior to chemotherapy and continued throughout anthracycline treatment. Post-testing occurred 3-7 days following the last anthracycline treatment. VO2peak (L/min) was reduced by 16% in the control group (P < 0.05), whereas VO2peak was preserved in the exercise preconditioning group. Trends for greater preservation and/or improvement in the exercise preconditioning group were also observed for lean body mass and peak heart rate. Hand grip strength was not changed in either group (P > 0.05). Both groups demonstrated an increase in ultrasound-derived echogenicity measures of the vastus lateralis (P < 0.05), indicating changes in the composition of the skeletal muscle during treatment. These preliminary data highlight that exercise preconditioning may serve as a strategy to preserve cardiorespiratory fitness and perhaps lean mass during anthracycline treatment of breast cancer. There remains a need for larger, definitive clinical trials to identify strategies to prevent the array of chemotherapy-induced toxicities that are observed in breast cancer patients treated with anthracyclines.
ContributorsCasey, Kathleen (Author) / Angadi, Siddhartha (Thesis director) / Gaesser, Glenn (Committee member) / Dickinson, Jared (Committee member) / College of Health Solutions (Contributor) / Barrett, The Honors College (Contributor)
Created2020-05