133885-Thumbnail Image.png
Description
The purpose of this thesis experiment was to design and create an Acoustically Active Cannula (AAC), which is furnished by a piezoelectric crystal placed at its tip that produces an acoustic navigation signal. I tested the functionality of the cannula in vitro and demonstrated its navigational abilities in vivo in

The purpose of this thesis experiment was to design and create an Acoustically Active Cannula (AAC), which is furnished by a piezoelectric crystal placed at its tip that produces an acoustic navigation signal. I tested the functionality of the cannula in vitro and demonstrated its navigational abilities in vivo in anesthetized pigs. This experiment was based upon ultrasound science and technology, and thus some practical experience with conventional (B-mode) and Doppler ultrasound was achieved as well. The results of bench and experimental animal studies indicated proper functionality of the AAC for identification and spatial navigation of its tip with color Doppler ultrasound imaging.
ContributorsShamsa, Kayvan (Author) / Tyler, William (Thesis director) / Belohlavek, Marek (Committee member) / School of Molecular Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2018-05
135723-Thumbnail Image.png
Description
This purpose of this study was to develop reliable methods for ultrasound measurements of skeletal muscle architecture, and to identify which specific quadriceps measurements most closely relate to peak isometric torque of the leg extensors. These data were obtained as part of a larger research study and consist of 9

This purpose of this study was to develop reliable methods for ultrasound measurements of skeletal muscle architecture, and to identify which specific quadriceps measurements most closely relate to peak isometric torque of the leg extensors. These data were obtained as part of a larger research study and consist of 9 total subjects (4 males, 5 females; age (30.6 ± 13.6yr). Ultrasound images for muscle thickness and pennation angle were obtained for each subject during two separate testing days (separated by 5-10 days). Images were acquired at various anatomical sites of the quadriceps and each image was analyzed using Image J software. Quadriceps muscles assessed for muscle thickness and pennation angle included the vastus lateralis (VL), and vastus intermedius (VI), while rectus femoris (RF) was assessed only for muscle thickness. Peak isometric torque measurements were obtained at 60 degrees of knee angle for knee extension using an isokinetic dynamometer. Results show that the methods chosen for ultrasound measurement produced reliable inter-day results for muscle thickness and pennation angle. VL muscle thickness and pennation angle obtained at the lateral site corresponding to 39% of leg length was highly related to peak isometric torque for knee extension. The results of this study identify specific measurement sites that are related to muscle function. In addition, these data further validate that ultrasound measurement is reliable to measure muscle thickness and pennation angle in skeletal muscle.
ContributorsSkotak, Nathaniel James (Author) / Dickinson, Jared (Thesis director) / Vidt, Meghan (Committee member) / Luden, Nick (Committee member) / School of Nutrition and Health Promotion (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
171798-Thumbnail Image.png
Description
The blood-brain-barrier (BBB) is a significant obstacle for treating many neurological disorders. Bubble-assisted focused ultrasound (BAFUS) medicated BBB disruption is a promising technology that enables the delivery of large drug doses at targeted locations across the BBB. However, the current lack of an in vitro model of this process hinders

The blood-brain-barrier (BBB) is a significant obstacle for treating many neurological disorders. Bubble-assisted focused ultrasound (BAFUS) medicated BBB disruption is a promising technology that enables the delivery of large drug doses at targeted locations across the BBB. However, the current lack of an in vitro model of this process hinders the full understanding of BAFUS BBB disruption for better translation into clinics. In this work, a US-transparent organ-on-chip device has been fabricated that can be critical for the in vitro modeling of the BAFUS BBB disruption. The transparency of the device window to focused ultrasound (FUS) was calculated theoretically and demonstrated by experiments. Nanobubbles were fabricated, characterized by cryogenic transmission electron microscopy (cryo-TEM), and showed bubble cavitation under FUS. Human colorectal adenocarcinoma (Caco-2) cells were used to form a good cellular barrier for BAFUS barrier disruption, as suggested by the measured permeability and transepithelial electrical resistance (TEER). Finally, barrier disruption and recovery were observed in BAFUS disrupted US-transparent organ-on-chips with Caco-2 barriers, showing great promise of the platform for future modeling BAFUS BBB disruption in vitro.
ContributorsAkkad, Adam Rifat (Author) / Gu, Jian (Thesis advisor) / Nikkhah, Mehdi (Thesis advisor) / Belohlavek, Marek (Committee member) / Wang, Xiao (Committee member) / Arizona State University (Publisher)
Created2022
153706-Thumbnail Image.png
Description
The application of novel visualization and modeling methods to the study of cardiovascular disease is vital to the development of innovative diagnostic techniques, including those that may aid in the early detection and prevention of cardiovascular disorders. This dissertation focuses on the application of particle image velocimetry (PIV) to the

The application of novel visualization and modeling methods to the study of cardiovascular disease is vital to the development of innovative diagnostic techniques, including those that may aid in the early detection and prevention of cardiovascular disorders. This dissertation focuses on the application of particle image velocimetry (PIV) to the study of intracardiac hemodynamics. This is accomplished primarily though the use of ultrasound based PIV, which allows for in vivo visualization of intracardiac flow without the requirement for optical access, as is required with traditional camera-based PIV methods.

The fundamentals of ultrasound PIV are introduced, including experimental methods for its implementation as well as a discussion on estimating and mitigating measurement error. Ultrasound PIV is then compared to optical PIV; this is a highly developed technique with proven accuracy; through rigorous examination it has become the “gold standard” of two-dimensional flow visualization. Results show good agreement between the two methods.

Using a mechanical left heart model, a multi-plane ultrasound PIV technique is introduced and applied to quantify a complex, three-dimensional flow that is analogous to the left intraventricular flow. Changes in ventricular flow dynamics due to the rotational orientation of mechanical heart valves are studied; the results demonstrate the importance of multi-plane imaging techniques when trying to assess the strongly three-dimensional intraventricular flow.

The potential use of ultrasound PIV as an early diagnosis technique is demonstrated through the development of a novel elasticity estimation technique. A finite element analysis routine is couple with an ensemble Kalman filter to allow for the estimation of material elasticity using forcing and displacement data derived from PIV. Results demonstrate that it is possible to estimate elasticity using forcing data derived from a PIV vector field, provided vector density is sufficient.
ContributorsWesterdale, John Curtis (Author) / Adrian, Ronald (Thesis advisor) / Belohlavek, Marek (Committee member) / Squires, Kyle (Committee member) / Trimble, Steve (Committee member) / Frakes, David (Committee member) / Arizona State University (Publisher)