Matching Items (5)
Filtering by

Clear all filters

153232-Thumbnail Image.png
Description
Since its first report in 1976, many outbreaks of Legionella have been reported in the world. These outbreaks are a public health concern because of legionellosis, which cause Pontiac fever and Legionnaires disease. Legionnaires disease is a type of pneumonia responsible for the majority of the illness in

Since its first report in 1976, many outbreaks of Legionella have been reported in the world. These outbreaks are a public health concern because of legionellosis, which cause Pontiac fever and Legionnaires disease. Legionnaires disease is a type of pneumonia responsible for the majority of the illness in the reported outbreaks. This study consists of an extensive literature review and experimental work on the aerosolization of Legionella and a bacterial surrogate under laboratory conditions. The literature review summarizes Legionella characteristics, legionellosis, potential sources of Legionella, disease outbreaks, collection and detection methodologies, environmental conditions for growth and survival of Legionella, Gaussian plume dispersion modeling, and recommendations for reducing potential Legionella outbreaks. The aerosolization and airborne dispersion of Legionella and E. coli was conducted separately inside of a closed environment. First, the bacterial cells were sprayed inside of an airtight box and then samples were collected using a microbial air sampler to measure the number of bacterial cells aerosolized and transported in air. Furthermore, a Gaussian plume dispersion model was used to estimate the dispersion under the experimental conditions and parameters. The concentration of Legionella was estimated for a person inhaling the air at three different distances away from the spray. The concentration of Legionella at distances of 0.1 km, 1 km, and 10 km away from the source was predicted to be 1.7x10-1, 2.2x10-3, and 2.6x10-5 CFU/m3, respectively.
ContributorsTaghdiri, Sepideh (Author) / Abbaszadegan, Morteza (Thesis advisor) / Fox, Peter (Committee member) / Estes, Robert (Committee member) / Arizona State University (Publisher)
Created2014
153234-Thumbnail Image.png
Description
Granular activated carbon (GAC) filters are final polishing step in the drinking water treatment systems for removal of dissolved organic carbon fractions. Generally filters are colonized by bacterial communities and their activity reduces biodegradable solutes allowing partial regeneration of GAC's adsorptive capacity. When the bacteria pass into the filtrate due

Granular activated carbon (GAC) filters are final polishing step in the drinking water treatment systems for removal of dissolved organic carbon fractions. Generally filters are colonized by bacterial communities and their activity reduces biodegradable solutes allowing partial regeneration of GAC's adsorptive capacity. When the bacteria pass into the filtrate due to increased growth, microbiological quality of drinking water is compromised and regrowth in the distribution system occurs. Bacteria attached to carbon particles as biofilms or in conjugation with other bacteria were observed to be highly resistant to post filtration microbial mitigation techniques. Some of these bacteria were identified as pathogenic.

This study focuses on one such pathogen Legionella pneumophila which is resistant to environmental stressors and treatment conditions. It is also responsible for Legionnaires' disease outbreak through drinking water thus attracting attention of regulatory agencies. The work assessed the attachment and colonization of Legionella and heterotrophic bacteria in lab scale GAC media column filters. Quantification of Legionella and HPC in the influent, effluent, column's biofilms and on the GAC particles was performed over time using fluorescent microscopy and culture based techniques.

The results indicated gradual increase in the colonization of the GAC particles with HPC bacteria. Initially high number of Legionella cells were detected in the column effluent and were not detected on GAC suggesting low attachment of the cells to the particles potentially due to lack of any previous biofilms. With the initial colonization of the filter media by other bacteria the number of Legionella cells on the GAC particles and biofilms also increased. Presence of Legionella was confirmed in all the samples collected from the columns spiked with Legionella. Significant increase in the Legionella was observed in column's inner surface biofilm (0.25 logs up to 0.52 logs) and on GAC particles (0.42 logs up to 0.63 logs) after 2 months. Legionella and HPC attached to column's biofilm were higher than that on GAC particles indicating the strong association with biofilms. The bacterial concentration slowly increased in the effluent. This may be due to column's wall effect decreasing filter efficiency, possible exhaustion of GAC capacity over time and potential bacterial growth.
ContributorsSharma, Harsha (Author) / Abbaszadegan, Morteza (Thesis advisor) / Alum, Absar (Committee member) / Fox, Peter (Committee member) / Arizona State University (Publisher)
Created2014
156415-Thumbnail Image.png
Description
Mexico City has an ongoing air pollution issue that negatively affects its citizens and surroundings with current structural disconnections preventing the city from improving its overall air quality. Thematic methodological analysis reveals current obstacles and barriers, as well as variables contributing to this persistent problem. A historical background reveals current

Mexico City has an ongoing air pollution issue that negatively affects its citizens and surroundings with current structural disconnections preventing the city from improving its overall air quality. Thematic methodological analysis reveals current obstacles and barriers, as well as variables contributing to this persistent problem. A historical background reveals current programs and policies implemented to improve Mexico’s City air quality. Mexico City’s current systems, infrastructure, and policies are inadequate and ineffective. There is a lack of appropriate regulation on other modes of transportation, and the current government system fails to identify how the class disparity in the city and lack of adequate education are contributing to this ongoing problem. Education and adequate public awareness can potentially aid the fight against air pollution in the Metropolitan City.
ContributorsGarcia, Lucero (Author) / Duarte, Marisa E. (Thesis advisor) / Arzubiaga, Angela (Committee member) / Richter, Jennifer (Committee member) / Arizona State University (Publisher)
Created2018
156429-Thumbnail Image.png
Description
Legionella pneumophila is a waterborne pathogen that causes Legionnaires' disease, an infection which can lead to potentially fatal pneumonia. In a culture-based technique, Legionella is detected using buffered charcoal-yeast extract (BCYE) agar supplemented with L-cysteine, Iron salt and antibiotics. These supplements provide essential and complex nutrient requirements and help in

Legionella pneumophila is a waterborne pathogen that causes Legionnaires' disease, an infection which can lead to potentially fatal pneumonia. In a culture-based technique, Legionella is detected using buffered charcoal-yeast extract (BCYE) agar supplemented with L-cysteine, Iron salt and antibiotics. These supplements provide essential and complex nutrient requirements and help in the suppression of non-target bacteria in Legionella analysis. Legionella occurs naturally in freshwater environments and for their detection; a sample is plated on solid agar media and then incubated for several days. There are many challenges in the detection of Legionella in environmental waters and the built environments. A common challenge is that a variety of environmental bacteria can be presumptively identified as Legionella using the culture-based method. In addition, proper identification of Legionella requires long incubation period (3-9 days) while antibiotics used in BCYE agar have relatively short half-life time. In order to overcome some of the challenges, Legionella has been genetically modified to express reporter genes such Green Fluorescent Protein (GFP) that can facilitate its detection in process validation studies under controlled laboratory conditions. However, such studies had limited success due to the instability of genetically modified Legionella strains. The development of a genetically modified Legionella with a much rapid growth rate (1-2 days) in simulated environmental systems (tightly-controlled water distribution system) is achieved. The mutant Legionella is engineered by transforming with a specific plasmid encoding CymR, LacZ and TetR genes. The newly engineered Legionella can grow on conventional BCYE agar media without L-Cysteine, Iron salt and only require one antibiotic (Tetracycline) to suppress the growth of other microorganisms in media. To the best of our knowledge, this is the first report of L. pneumophila strain capable of growing without L-Cysteine. We believe that this discovery would not only facilitate the study of the fate and transport of this pathogen in environmental systems, but also further our understanding of the genetics and metabolic pathways of Legionella.
ContributorsAloraini, Saleh Ali A (Author) / Abbaszadegan, Morteza (Thesis advisor) / Fox, Peter (Committee member) / Alum, Absar (Committee member) / Arizona State University (Publisher)
Created2018
154207-Thumbnail Image.png
Description
Since its first report in 1976, many outbreaks linked to Legionella have been reported in the world. These outbreaks are a public health concern because of legionellosis, which is found in two forms, Pontiac fever and Legionnaires disease. Legionnaires disease is a type of pneumonia responsible for the majority of

Since its first report in 1976, many outbreaks linked to Legionella have been reported in the world. These outbreaks are a public health concern because of legionellosis, which is found in two forms, Pontiac fever and Legionnaires disease. Legionnaires disease is a type of pneumonia responsible for the majority of the illness in the reported outbreaks of legionellosis. This study consists of an extensive literature review and experimental work on the aerosolization and UV inactivation of E.coli and Legionella under laboratory conditions. The literature review summarizes Legionella general information, occurrence, environmental conditions for its survival, transmission to human, collection and detection methodologies and Legionella disinfection in air and during water treatment processes.

E. coli was used as an surrogate for Legionella in experimentation due to their similar bacterial properties such as size, gram-negative rod-shaped, un-encapsulated and non-spore-forming bacterial cells. The accessibility and non-pathogenicity of E. coli also served as factors for the substitution.

Three methods of bacterial aerosolization were examined, these included an electric spray gun, an air spray gun and a hand-held spray bottle. A set of experiments were performed to examine E. coli aerosolization and transport in the aerosolization chamber (an air tight box) placed in a Biological Safety Cabinet. Spiked sample was sprayed through the opening from one side of the aerosolization chamber using the selected aerosolization methods. The air sampler was placed at the other side to collect 100 L air sample from the aerosolization chamber. A Tryptic Soy Agar plate was placed inside the air sampler to collect and subsequently culture E. coli cells from air. Results showed that the air spray gun has the best capability of aerosolizing bacteria cells under all the conditions examined in this study compared to the other two spray methods. In this study, we provide a practical and efficient method of bacterial aerosolization technique for microbial dispersion in air. The suggested method can be used in future research for microbial dispersion and transmission studies.

A set of experiments were performed to examine UV inactivation of E. coli and Legionella cells in air. Spiked samples were sprayed through the opening from one side of the aerosolization chamber using the air spray gun. A UV-C germicidal lamp inside the Biological Safety Cabinet was turned on after each spray. The air samples were collected as previously described. The application of UV-C for the inactivation of bacterial cells resulted in removing aerosolized E. coli and Legionella cells in air. A 1 log reduction was achieved with 5 seconds UV exposure time while 10 seconds UV exposure resulted in a 2 log bacterial reduction for both bacteria. This study shows the applicability of UV inactivation of pathogenic bacterial cells in air by short UV exposure time. This method may be applicable for the inactivation of Legionella in air ducts by installing germicidal UV lamps for protecting susceptible populations in certain indoor settings such as nursing homes or other community rooms.
ContributorsYao, Wei (Author) / Abbaszadegan, Morteza (Thesis advisor) / Fox, Peter (Committee member) / Alum, Absar (Committee member) / Arizona State University (Publisher)
Created2015