Matching Items (24)
136421-Thumbnail Image.png
Description
Bacteria play a vital role in the world ecosystem, more importantly human health and disease. The capability to differentiate and identify these microorganisms serves as an important research objective. In past years, separations-based approaches have served as a way to observe and identify bacteria based on their characteristics. Gradient insulator

Bacteria play a vital role in the world ecosystem, more importantly human health and disease. The capability to differentiate and identify these microorganisms serves as an important research objective. In past years, separations-based approaches have served as a way to observe and identify bacteria based on their characteristics. Gradient insulator dielectrophoresis (g-iDEP) provides benefits in identifying serotypes of a single species with precise separation. Separation of Staphylococcus epidermidis in a single g-iDEP microchannel is conducted exploiting their electrophoretic and electrokinetic properties. The cells were captured and concentrated at gates with interacting forces within the microchannel to clearly distinguish between the two strains. These results provide support for g-iDEP serving as a separating method and, furthermore, future clinical applications.
ContributorsDavis, Paige Elizabeth (Author) / Hayes, Mark (Thesis director) / Borges, Chad (Committee member) / Jones, Paul (Committee member) / Barrett, The Honors College (Contributor) / Department of Chemistry and Biochemistry (Contributor) / T. Denny Sanford School of Social and Family Dynamics (Contributor)
Created2015-05
137416-Thumbnail Image.png
Description
Microfluidics is an expanding research area for analytical chemistry and the biomedical industry. Microfludic devices have been used for protein and DNA sorting, early detection techniques for cancer and other disease, and a variety of other analytical techniques. Dielectrophoresis is a technique is often used to control particles within microfluidic

Microfluidics is an expanding research area for analytical chemistry and the biomedical industry. Microfludic devices have been used for protein and DNA sorting, early detection techniques for cancer and other disease, and a variety of other analytical techniques. Dielectrophoresis is a technique is often used to control particles within microfluidic devices however the non-uniform electric field can affect the interior of the device. In order to expand the applications of microfluidic devices and to make it easier to work with techniques such as dielectrophoresis, it is essential to understand as much as possible about how the internal environment of the device will affect the sample. A significant part of this is being able to non-invasively determine the temperature inside the microfluidic device in the both the channel and reservoir regions. Several other research group have successfully used temperature sensitive dyes and fluorescence to measure the temperature within microfluidic devices so research began with understanding their techniques and trying to optimize them for the chosen microfluidic channel. Results from calibration and reservoir tests show that there is a linear relationship between the temperature of the channel and the ratio between the dyes Rhodamine 110 and Rhodamine B. Results within the channel showed that the calibration may be difficult to apply directly as absorption from the PDMS continues to be a problem but several coatings can be used to improve the results.
ContributorsBush, Kathleen (Author) / Ros, Alexandra (Thesis director) / Hayes, Mark (Committee member) / Alanis, Fernanda Camacho (Committee member) / Barrett, The Honors College (Contributor)
Created2013-12
153628-Thumbnail Image.png
Description
Biological fluids contain information-rich mixtures of biochemicals and particles such as cells, proteins, and viruses. Selective and sensitive analysis of these fluids can enable clinicians to accurately diagnose a wide range of pathologies. Fluid samples such as these present an intriguing challenge to researchers; they are packed with potentially vital

Biological fluids contain information-rich mixtures of biochemicals and particles such as cells, proteins, and viruses. Selective and sensitive analysis of these fluids can enable clinicians to accurately diagnose a wide range of pathologies. Fluid samples such as these present an intriguing challenge to researchers; they are packed with potentially vital information, but notoriously difficult to analyze. Rapid and inexpensive analysis of blood and other bodily fluids is a topic gaining substantial attention in both science and medicine. Current limitations to many analyses include long culture times, expensive reagents, and the need for specialized laboratory facilities and personnel. Improving these tests and overcoming their limitations would allow faster and more widespread testing for disease and pathogens, potentially providing a significant advantage for healthcare in many settings.

Both gradient separation techniques and dielectrophoresis can solve some of the difficulties presented by complex biological samples, thanks to selective capture, isolation, and concentration of analytes. By merging dielectrophoresis with a gradient separation-based approach, gradient insulator dielectrophoresis (g-iDEP) promises benefits in the form of rapid and specific separation of extremely similar bioparticles. High-resolution capture can be achieved by exploiting variations in the characteristic physical properties of cells and other bioparticles.

Novel implementation and application of the technique has demonstrated the isolation and concentration of blood cells from a complex biological sample, differentiation of bacterial strains within a single species, and separation of antibiotic-resistant and antibiotic-susceptible bacteria. Furthermore, this approach allows simultaneous concentration of analyte, facilitating detection and downstream analysis. A theoretical description of the resolving capabilities of g-iDEP was also developed. This theory explores the relationship between experimental parameters and resolution. Results indicate the possibility of differentiating particles with dielectrophoretic mobilities that differ by as little as one part in 100,000,000, or electrophoretic mobilities differing by as little as one part in 100,000. These results indicate the potential g-iDEP holds in terms of both separatory power and the possibility for diagnostic applications.
ContributorsJones, Paul Vernon (Author) / Hayes, Mark (Thesis advisor) / Ros, Alexandra (Committee member) / Herckes, Pierre (Committee member) / Arizona State University (Publisher)
Created2015
154445-Thumbnail Image.png
Description
X-ray crystallography is the most widely used method to determine the structure of proteins, providing an understanding of their functions in all aspects of life to advance applications in fields such as drug development and renewable energy. New techniques, namely serial femtosecond crystallography (SFX), have unlocked the ability to unravel

X-ray crystallography is the most widely used method to determine the structure of proteins, providing an understanding of their functions in all aspects of life to advance applications in fields such as drug development and renewable energy. New techniques, namely serial femtosecond crystallography (SFX), have unlocked the ability to unravel the structures of complex proteins with vital biological functions. A key step and major bottleneck of structure determination is protein crystallization, which is very arduous due to the complexity of proteins and their natural environments. Furthermore, crystal characteristics govern data quality, thus need to be optimized to attain the most accurate reconstruction of the protein structure. Crystal size is one such characteristic in which narrowed distributions with a small modal size can significantly reduce the amount of protein needed for SFX. A novel microfluidic sorting platform was developed to isolate viable ~200 nm – ~600 nm photosystem I (PSI) membrane protein crystals from ~200 nm – ~20 μm crystal samples using dielectrophoresis, as confirmed by fluorescence microscopy, second-order nonlinear imaging of chiral crystals (SONICC), and dynamic light scattering. The platform was scaled-up to rapidly provide 100s of microliters of sorted crystals necessary for SFX, in which similar crystal size distributions were attained. Transmission electron microscopy was used to view the PSI crystal lattice, which remained well-ordered postsorting, and SFX diffraction data was obtained, confirming a high-quality, viable crystal sample. Simulations indicated sorted samples provided accurate, complete SFX datasets with 3500-fold less protein than unsorted samples. Microfluidic devices were also developed for versatile, rapid protein crystallization screening using nanovolumes of sample. Concentration gradients of protein and precipitant were generated to crystallize PSI, phycocyanin, and lysozyme using modified counterdiffusion. Additionally, a passive mixer was created to generate unique solution concentrations within isolated nanowells to crystallize phycocyanin and lysozyme. Crystal imaging with brightfield microscopy, UV fluorescence, and SONICC coupled with numerical modeling allowed quantification of crystal growth conditions for efficient phase diagram development. The developed microfluidic tools demonstrated the capability of improving samples for protein crystallography, offering a foundation for continued development of platforms to aid protein structure determination.
ContributorsAbdallah, Bahige G (Author) / Ros, Alexandra (Thesis advisor) / Buttry, Daniel (Committee member) / Hayes, Mark (Committee member) / Arizona State University (Publisher)
Created2016
135861-Thumbnail Image.png
Description
Dielectrophoresis is a separations strategy that has the potential to separate small amounts of different proteins from each other. The forces at play in the channel used for dielectrophoresis are electroosmotic flow (EOF), electrophoresis (EP), and dielectrophoresis (DEP). EOF is the force exerted on liquid from an applied potential (1).

Dielectrophoresis is a separations strategy that has the potential to separate small amounts of different proteins from each other. The forces at play in the channel used for dielectrophoresis are electroosmotic flow (EOF), electrophoresis (EP), and dielectrophoresis (DEP). EOF is the force exerted on liquid from an applied potential (1). EP is the force exerted on charged particles in a uniform electric field (2). DEP is the force exerted on particles (charged and uncharged) in a non-uniform electric field (3). This experiment was focused on the testing of a new microfluidic device to see if it could improve the focusing of proteins in dielectrophoresis. It was predicted that the addition of a salt bridge would improve focusing by preventing the ions created by the electrolysis of water around the electrodes from interacting with the proteins and causing aggregation, among other problems. Control trials using the old device showed that electrolysis was likely occurring and was the causal agent for poor outcomes. After applying the electric potential for some time a pH front traveled through the channel causing aggregation of proteins and the current in the channel decreased rapidly, even while the voltage was held constant. The resistance in the channels of the control trials also slightly decreased over time, until the pH shift occurred, at which time it increased rapidly. Experimental trials with a new device that included salt bridges eliminated this pH front and had a roughly linear increase of current in the channel with the voltage applied. This device can now be used in future research with protein dielectrophoresis, including in the potential differentiation of different proteins. References: 1) Electroosmosis. Oxford Dictionary of Biochemistry and Molecular Biology. 2. Oxford University Press: Oxford, England. 2006. 2) Electrophoresis. Oxford Dictionary of Biochemistry and Molecular Biology. 2. Oxford University Press: Oxford, England. 2006. 3) Dielectrophoresis. Oxford Dictionary of Biochemistry and Molecular Biology. 2. Oxford University Press: Oxford, England. 2006.
ContributorsHayes, Katelyn Donna (Author) / Hayes, Mark (Thesis director) / Borges, Chad (Committee member) / School of Life Sciences (Contributor) / Department of Psychology (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
Description

Dielectrophoresis is an analytical technique which involves electroosmotic flow, electrophoresis, and dielectrophoretic force. These factors, when in correct proportions for a given analyte, allow for dielectrophoretic trapping, otherwise known as dielectrophoretic capture. Non-uniform electric fields are required for this phenomenon, and the device in this trial used to induce such

Dielectrophoresis is an analytical technique which involves electroosmotic flow, electrophoresis, and dielectrophoretic force. These factors, when in correct proportions for a given analyte, allow for dielectrophoretic trapping, otherwise known as dielectrophoretic capture. Non-uniform electric fields are required for this phenomenon, and the device in this trial used to induce such an electric field was a gradient insulator-based design. Similar devices have been previously used to separate or identify a wide variety of analytes within solution. Much of the previous work has been focused on the differences in dielectrophoretic trapping between strains of bacteria, whereas this experiment focused on the differentiation of phenotypes within a single bacterial strain, Staphylococcus aureus isolate 35984. A control sample was tested, as well as a sample heated at 70oC for 15 minutes to induce phenotypic changes. The control sample was found to exhibit dielectrophoretic capture at a given gate at a potential of 800V and higher, whereas the heated sample was not observed to capture at any potential in this experiment, which reached a maximum of 1200V. Notably, neither of the samples were found to capture at or below 600V. The results of this experiment were encouraging, though it is worth noting that several experimental trials failed to produce any noteworthy results. As such, the procedure of this experiment should be refined to increase reproducibility of results.

ContributorsLehfeldt, Jase (Author) / Hayes, Mark (Thesis director) / Sayres, Scott (Committee member) / Williams, Peter (Committee member) / Barrett, The Honors College (Contributor) / School of Molecular Sciences (Contributor)
Created2023-05
168413-Thumbnail Image.png
Description
Microfluidic platforms have been exploited extensively as a tool for the separation of particles by electric field manipulation. Microfluidic devices can facilitate the manipulation of particles by dielectrophoresis. Separation of particles by size and type has been demonstrated by insulator-based dielectrophoresis in a microfluidic device. Thus, manipulating particles by size

Microfluidic platforms have been exploited extensively as a tool for the separation of particles by electric field manipulation. Microfluidic devices can facilitate the manipulation of particles by dielectrophoresis. Separation of particles by size and type has been demonstrated by insulator-based dielectrophoresis in a microfluidic device. Thus, manipulating particles by size has been widely studied throughout the years. It has been shown that size-heterogeneity in organelles has been linked to multiple diseases from abnormal organelle size. Here, a mixture of two sizes of polystyrene beads (0.28 and 0.87 μm) was separated by a ratchet migration mechanism under a continuous flow (20 nL/min). Furthermore, to achieve high-throughput separation, different ratchet devices were designed to achieve high-volume separation. Recently, enormous efforts have been made to manipulate small size DNA and proteins. Here, a microfluidic device comprising of multiple valves acting as insulating constrictions when a potential is applied is presented. The tunability of the electric field gradient is evaluated by a COMSOL model, indicating that high electric field gradients can be reached by deflecting the valve at a certain distance. Experimentally, the tunability of the dynamic constriction was demonstrated by conducting a pressure study to estimate the gap distance between the valve and the substrate at different applied pressures. Finally, as a proof of principle, 0.87 μm polystyrene beads were manipulated by dielectrophoresis. These microfluidic platforms will aid in the understanding of size-heterogeneity of organelles for biomolecular assessment and achieve separation of nanometer-size DNA and proteins by dielectrophoresis.
ContributorsOrtiz, Ricardo (Author) / Ros, Alexandra (Thesis advisor) / Hayes, Mark (Committee member) / Borges, Chad (Committee member) / Arizona State University (Publisher)
Created2021
Description

An electric field can be applied to a microfluidic device in order to stop particle flow. Electroosmosis, electrophoresis, and dielectrophoresis act on the particles in different directions in the microfluidic channel, and when these forces create zero net force, the particle stops in the channel. The goal of the performed

An electric field can be applied to a microfluidic device in order to stop particle flow. Electroosmosis, electrophoresis, and dielectrophoresis act on the particles in different directions in the microfluidic channel, and when these forces create zero net force, the particle stops in the channel. The goal of the performed experiments is to investigate whether hydrostatic pressure generated by a syringe pump could help concentrate these particles and separate them from other contents. Introducing precise, adjustable hydrostatic pressure from the syringe pump provides another mechanism for controlling particle behavior. A microfluidic channel was crafted into a device connected to a syringe pump, and videos of 1 µm silica particles in the device were recorded under a microscope in order to show that samples could be infused into the device and concentrated or captured at a specific location in the channel using hydrostatic pressure. Capture of the particles occurred with and without controlled hydrostatic pressure, but these events occurred somewhat consistently at different voltages. In addition, particle movement in the channel with the syringe pump off was originally attributed to the electrokinetic forces. However, when compared to experiments without the syringe pump connected to the device, it became evident that the electrokinetic forces should have moved the particles in the opposite direction and that, in actuality, there is an inherent pressure in the device also affecting particle movement even when the syringe pump is not turned on.

ContributorsRuddle, Kallen (Author) / Hayes, Mark (Thesis director) / Guo, Jia (Committee member) / Hogue, Brenda (Committee member) / Barrett, The Honors College (Contributor) / School of Molecular Sciences (Contributor)
Created2022-12
171872-Thumbnail Image.png
Description
Understanding solvent-mediated interactions in biomolecular systems at the molecular level is important for the development of predictive models for processes such as protein folding and ligand binding to a host biomolecule. Solvent-mediated interactions can be quantified as changes in the solvation free energy of solvated molecules. Theoretical models of solvent-mediated

Understanding solvent-mediated interactions in biomolecular systems at the molecular level is important for the development of predictive models for processes such as protein folding and ligand binding to a host biomolecule. Solvent-mediated interactions can be quantified as changes in the solvation free energy of solvated molecules. Theoretical models of solvent-mediated interactions thus need to include ensemble-averaged solute-solvent interactions. In this thesis, molecular dynamics simulations were coupled with the 3D-2PT method to decompose solvation free energies into spatially resolved local contributions. In the first project, this approach was applied to benzene derivatives to guide the development of efficient and predictive models of solvent-mediated interactions in the context of computational drug design. Specifically, the effects of carboxyl and nitro groups on solvation were studied due to their similar sterical requirements but distinct interactions with water. A system of solvation free energy arithmetics was developed and showed that non-additive contributions to the solvation free energy originate in electrostatic solute-solvent interactions, which are qualitatively reproduced by computationally efficient continuum models. In the second project, a simple model system was used to analyze hydrophilic water-mediated interactions (water-mediated hydrogen bonds), which have been previously suggested to play a key role in protein folding. Using the spatially resolved analysis of solvation free energies, the sites of bridging water molecules were identified as the primary origin of solvent-mediated forces and showed that changes in hydration shell structure can be neglected. In the third project, the analysis of solvation free energy contributions is applied to proteins in inhomogeneous electric fields to explore water-mediated contributions to protein dielectrophoresis. The results provide a potential explanation for negative dielectrophoretic forces on proteins, which have been observed experimentally but cannot be explained with previous theoretical models.
ContributorsLazaric, Aleksandar (Author) / Heyden, Matthias (Thesis advisor) / Ozkan, Banu S (Committee member) / Sulc, Petr (Committee member) / Arizona State University (Publisher)
Created2022
171881-Thumbnail Image.png
Description
Microfluidics has enabled many biological and biochemical applications such as high-throughput drug testing or point-of-care diagnostics. Dielectrophoresis (DEP) has recently achieved prominence as a powerful microfluidic technique for nanoparticle separation. Novel electric field-assisted insulator-based dielectrophoresis (iDEP) microfluidic devices have been employed to fractionate rod-shaped nanoparticles like Single-walled carbon nanotubes (SWNTs)

Microfluidics has enabled many biological and biochemical applications such as high-throughput drug testing or point-of-care diagnostics. Dielectrophoresis (DEP) has recently achieved prominence as a powerful microfluidic technique for nanoparticle separation. Novel electric field-assisted insulator-based dielectrophoresis (iDEP) microfluidic devices have been employed to fractionate rod-shaped nanoparticles like Single-walled carbon nanotubes (SWNTs) and manipulate biomolecules like Deoxyribonucleic acid (DNA) and proteins. This dissertation involves the development of traditional as well as 3D-printed iDEP devices for the manipulation of nm-to-µm scale analytes. First, novel iDEP microfluidic constriction-based sorting devices were developed to introduce inhomogeneous electric field gradients to fractionate SWNTs by length. SWNTs possess length-specific optical and electrical properties, expanding their potential applications for future nanoscale devices. Standard synthesis procedures yield SWNTs in large-length polydispersity and chirality. Thus, an iDEP-based fractionation tool for desired lengths of SWNTs may be beneficial. This dissertation presents the first study of DEP characterization and fractionation of SWNTs using an iDEP microfluidic device. Using this iDEP constriction sorter device, two different length distributions of SWNTs were sorted with a sorting efficiency of >90%. This study provides the fundamentals of fractionating SWNTs by length, which can help separate and purify SWNTs for future nanoscale-based applications. Manipulation of nm-scale analytes requires achieving high electric field gradients in an iDEP microfluidic device, posing one of the significant challenges for DEP applications. Introducing nm-sized constrictions in an iDEP device can help generate a higher electric field gradient. However, this requires cumbersome and expensive fabrication methods. In recent years, 3D printing has drawn tremendous attention in microfluidics, alleviating complications associated with complex fabrication methods. A high-resolution 3D-printed iDEP device was developed and fabricated for iDEP-based manipulation of analytes. A completely 3D-printed device with 2 µm post-gaps was realized, and fluorescent polystyrene (PS) beads, λ-DNA, and phycocyanin protein trapping were demonstrated. Furthermore, a nm-resolution 3D-printed iDEP device was successfully printed. In the future, these high-resolution 3D-printed devices may lead to exploring DEP characteristics of nanoscale analytes like single protein molecules and viruses. The electric field-assisted unique fractionation phenomena in microfluidic platforms will become a critical solution for nanoparticle separation and manipulating biomolecules.
ContributorsRabbani, Mohammad Towshif (Author) / Ros, Alexandra (Thesis advisor) / Stephanopoulos, Nicholas (Committee member) / Buttry, Daniel (Committee member) / Arizona State University (Publisher)
Created2022