134487-Thumbnail Image.png
Description
Monatomic gases are ideal working mediums for Brayton cycle systems due to their favorable thermodynamic properties. Closed Brayton cycle systems make use of these monatomic gases to increase system performance and thermal efficiency. Open Brayton cycles, on the other hand, operate with primarily diatomic and polyatomic gases from air and

Monatomic gases are ideal working mediums for Brayton cycle systems due to their favorable thermodynamic properties. Closed Brayton cycle systems make use of these monatomic gases to increase system performance and thermal efficiency. Open Brayton cycles, on the other hand, operate with primarily diatomic and polyatomic gases from air and combustion products, which have less favorable properties. The focus of this study is to determine if monatomic gases can be utilized in an open Brayton cycle system, in a way that increases the overall performance, but is still cost effective.
Two variations on open cycle Brayton systems were analyzed, consisting of an “airborne” thrust producing propulsion system, and a “ground-based” power generation system. Both of these systems have some mole fraction of He, Ne, or Ar injected into the flow path at the inlet, and some fraction of monatomic gas recuperated and at the nozzle exit to be re-circulated through the system. This creates a working medium of an air-monatomic gas mixture before the combustor, and a combustion products-monatomic gas mixture after combustor. The system’s specific compressor work, specific turbine work, specific net power output, and thermal efficiency were analyzed for each case. The most dominant metric for performance is the thermal efficiency (η_sys), which showed a significant increase as the mole fraction of monatomic gas increased for all three gas types. With a mole fraction of 0.15, there was a 2-2.5% increase in the airborne system, and a 1.75% increase of the ground-based system. This confirms that “spiking” any open Brayton system with monatomic gas will lead to an increase in performance. Additionally, both systems showed an increase in compressor and turbine work for a set temperature difference with He and Ne, which can additionally lead to longer component lifecycles with less frequent maintenance checks.
The cost analysis essentially compares the operating cost of a standard system with the operating cost of the monatomic gas “spiked” system, while keeping the internal mass flow rate and total power output the same. This savings is denoted as a percent of the standard system with %NCS. This metric lumps the cost ratio of the monatomic gas and fuel (MGC/FC) with the fraction of recuperated monatomic gas (RF) into an effective cost ratio that represents the cost per second of monatomic gas injected into the system. Without recuperation, the results showed there is no mole fraction of any monatomic gas type that yields a positive %NCS for a reasonable range of current MGC/FC values. Integrating recuperation machinery in an airborne system is hugely impractical, effectively meaning that the use of monatomic gas in this case is not feasible. For a ground-based system on the other hand, recuperation is much more practical. The ground-based system showed that a RF value of at least 50% for He, 89% for Ne, and 94% for Ar is needed for positive savings. This shows that monatomic gas could theoretically be used cost effectively in a ground-based, power-generating open Brayton system. With an injected monatomic gas mole fraction of 0.15, and full 100% recuperation, there is a net cost savings of about 3.75% in this ground-based system.
ContributorsBernaud, Ryan Clark (Author) / Dahm, Werner (Thesis director) / Wells, Valana (Committee member) / Mechanical and Aerospace Engineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2017-05
134678-Thumbnail Image.png
Description
Many industries require workers in warehouse and stockroom environments to perform frequent lifting tasks. Over time these repeated tasks can lead to excess strain on the worker's body and reduced productivity. This project seeks to develop an exoskeletal wrist fixture to be used in conjunction with a powered exoskeleton arm

Many industries require workers in warehouse and stockroom environments to perform frequent lifting tasks. Over time these repeated tasks can lead to excess strain on the worker's body and reduced productivity. This project seeks to develop an exoskeletal wrist fixture to be used in conjunction with a powered exoskeleton arm to aid workers performing box lifting types of tasks. Existing products aimed at improving worker comfort and productivity typically employ either fully powered exoskeleton suits or utilize minimally powered spring arms and/or fixtures. These designs either reduce stress to the user's body through powered arms and grippers operated via handheld controls which have limited functionality, or they use a more minimal setup that reduces some load, but exposes the user's hands and wrists to injury by directing support to the forearm. The design proposed here seeks to strike a balance between size, weight, and power requirements and also proposes a novel wrist exoskeleton design which minimizes stress on the user's wrists by directly interfacing with the object to be picked up. The design of the wrist exoskeleton was approached through initially selecting degrees of freedom and a ROM (range of motion) to accommodate. Feel and functionality were improved through an iterative prototyping process which yielded two primary designs. A novel "clip-in" method was proposed to allow the user to easily attach and detach from the exoskeleton. Designs utilized a contact surface intended to be used with dry fibrillary adhesives to maximize exoskeleton grip. Two final designs, which used two pivots in opposite kinematic order, were constructed and tested to determine the best kinematic layout. The best design had two prototypes created to be worn with passive test arms that attached to the user though a specially designed belt.
ContributorsGreason, Kenneth Berend (Author) / Sugar, Thomas (Thesis director) / Holgate, Matthew (Committee member) / Mechanical and Aerospace Engineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2016-12
133543-Thumbnail Image.png
Description
This paper studies the history and development of ion propulsion systems and survey past, present, and developing technology with their applications to space missions. This analysis addresses the physical design parameters and process that is a part of designing and optimizing a gridded ion thruster. It also identifies operational limits

This paper studies the history and development of ion propulsion systems and survey past, present, and developing technology with their applications to space missions. This analysis addresses the physical design parameters and process that is a part of designing and optimizing a gridded ion thruster. It also identifies operational limits that may be associated with solar-powered ion propulsion systems and posits plausible solutions or alternatives to remedy such limitations. These topics are presented with the intent of reviewing how ion propulsion technology evolved in its journey to develop to today's systems, and to facilitate thought and discussion on where further development of ion propulsion systems can be directed.
ContributorsTang, Justine (Author) / White, Daniel (Thesis director) / Dahm, Werner (Committee member) / Mechanical and Aerospace Engineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2018-05
134817-Thumbnail Image.png
Description
For the past two decades, advanced Limb Gait Simulators and Exoskeletons have been developed to improve walking rehabilitation. A Limb Gait Simulator is used to analyze the human step cycle and/or assist a user walking on a treadmill. Most modern limb gait simulators, such as ALEX, have proven themselves effective

For the past two decades, advanced Limb Gait Simulators and Exoskeletons have been developed to improve walking rehabilitation. A Limb Gait Simulator is used to analyze the human step cycle and/or assist a user walking on a treadmill. Most modern limb gait simulators, such as ALEX, have proven themselves effective and reliable through their usage of motors, springs, cables, elastics, pneumatics and reaction loads. These mechanisms apply internal forces and reaction loads to the body. On the other hand, external forces are those caused by an external agent outside the system such as air, water, or magnets. A design for an exoskeleton using external forces has seldom been attempted by researchers. This thesis project focuses on the development of a Limb Gait Simulator based on a Pure External Force and has proven its effectiveness in generating torque on the human leg. The external force is generated through air propulsion using an Electric Ducted Fan (EDF) motor. Such a motor is typically used for remote control airplanes, but their applications can go beyond this. The objective of this research is to generate torque on the human leg through the control of the EDF engines thrust and the opening/closing of the reverse thruster flaps. This device qualifies as "assist as needed"; the user is entirely in control of how much assistance he or she may want. Static thrust values for the EDF engine are recorded using a thrust test stand. The product of the thrust (N) and the distance on the thigh (m) is the resulting torque. With the motor running at maximum RPM, the highest torque value reached was that of 3.93 (Nm). The motor EDF motor is powered by a 6S 5000 mAh LiPo battery. This torque value could be increased with the usage of a second battery connected in series, but this comes at a price. The designed limb gait simulator demonstrates that external forces, such as air, could have potential in the development of future rehabilitation devices.
ContributorsToulouse, Tanguy Nathan (Author) / Sugar, Thomas (Thesis director) / Artemiadis, Panagiotis (Committee member) / Mechanical and Aerospace Engineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2016-12
Description
This thesis examines how a recently proposed concept for a highly-truncated aerospike nozzle can be expected to perform at altitudes corresponding to ambient pressures from sea-level to full vacuum conditions, as would occur during second-stage ascent and during second-stage descent and return to Earth. Of particular importance is how the base pressure varies

This thesis examines how a recently proposed concept for a highly-truncated aerospike nozzle can be expected to perform at altitudes corresponding to ambient pressures from sea-level to full vacuum conditions, as would occur during second-stage ascent and during second-stage descent and return to Earth. Of particular importance is how the base pressure varies with ambient pressure, especially at low ambient pressures for which the resulting highly underexpanded flows exiting from discrete thrust chambers around the truncated aerospike merge to create a closed (unventilated) base flow. The objective was to develop an approximate but usefully accurate and technically rooted way of estimating conditions for which the jets issuing from adjacent thrust chambers will merge before the end of the truncated aerospike is reached. Three main factors that determine the merging distance are the chamber pressure, the altitude, and the spacing between adjacent thrust chambers. The Prandtl-Meyer expansion angle was used to approximate the initial expansion of the jet flow issuing from each thrust chamber. From this an approximate criterion was developed for the downstream distance at which the jet flows from adjacent thrust chambers merge. Variations in atmospheric gas composition, specific heat ratio, temperature, and pressure with altitude from sea-level to 600 km were accounted for. Results showed that with decreasing atmospheric pressure during vehicle ascent, the merging distance decreases as the jet flows become increasingly under-expanded. Increasing the number of thrust chambers decreases the merging distance exponentially, and increasing chamber pressure results in a decrease of the merging distance as well.
ContributorsHerrington, Katie (Author) / Dahm, Werner (Thesis director) / Takahashi, Timothy (Committee member) / Barrett, The Honors College (Contributor) / Mechanical and Aerospace Engineering Program (Contributor) / Department of Physics (Contributor)