Description

The honors thesis presented in this document describes an extension to an electrical engineering capstone project whose scope is to develop the receiver electronics for an RF interrogator. The RF interrogator functions by detecting the change in resonant frequency of (i.e, frequency of maximum backscatter from) a target resulting

The honors thesis presented in this document describes an extension to an electrical engineering capstone project whose scope is to develop the receiver electronics for an RF interrogator. The RF interrogator functions by detecting the change in resonant frequency of (i.e, frequency of maximum backscatter from) a target resulting from an environmental input. The general idea of this honors project was to design three frequency selective surfaces that would act as surrogate backscattering or reflecting targets that each contains a distinct frequency response. Using 3-D electromagnetic simulation software, three surrogate targets exhibiting bandpass frequency responses at distinct frequencies were designed and presented in this thesis.

ContributorsSisk, Ryan Derek (Author) / Aberle, James (Thesis director) / Chakraborty, Partha (Committee member) / Electrical Engineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2021-05
191022-Thumbnail Image.png
Description
The field of non-invasive neurostimulation techniques offer promising avenues for the treatment of various neurological and psychiatric disorders such as Parkinson's disease, migraines, chronic pain, and epilepsy. The proposed work is a novel technique for the production of high-end ultrasonic forces by interaction of gigahertz electromagnetic radiations for the purpose

The field of non-invasive neurostimulation techniques offer promising avenues for the treatment of various neurological and psychiatric disorders such as Parkinson's disease, migraines, chronic pain, and epilepsy. The proposed work is a novel technique for the production of high-end ultrasonic forces by interaction of gigahertz electromagnetic radiations for the purpose of neural modulation. These ultrasonic forces are created in dielectric materials such as cell membranes by the electrostrive effect, providing a potential new neurotherapeutic technique. The ability for this technique to provide neurostimulatory effects was investigated using in vitro studies of neuronal cultures and in vivo studies on sciatic nerves. Direct exposure of E18 rat cortical neurons to these EM radiations demonstrated changes in cellular membrane potential, suggesting effects could be potentially similar to direct electrical stimulation. An exploration of neuromodulatory effects to rat sciatic nerves indicates exposure produces changes to peak-to-peak muscular response. These findings suggest promising results for this new potential neuromodulation modality.
ContributorsDagher, Michael Jonathan (Author) / Muthuswamy, Jitendran (Thesis advisor) / Towe, Bruce (Committee member) / Sridharan, Arati (Committee member) / Aberle, James (Committee member) / Arizona State University (Publisher)
Created2023
161752-Thumbnail Image.png
Description
Magnetic resonance spectroscopic imaging (MRSI) is a non-invasive technique that offers a unique ability to provide the spatial distribution of relevant biochemical compounds (metabolites). The ‘spectrum’ of information provided by MRSI is used as biomarkers for the differential diagnosis of several diseases such as cancer or neurological disorders. Treatment responsive

Magnetic resonance spectroscopic imaging (MRSI) is a non-invasive technique that offers a unique ability to provide the spatial distribution of relevant biochemical compounds (metabolites). The ‘spectrum’ of information provided by MRSI is used as biomarkers for the differential diagnosis of several diseases such as cancer or neurological disorders. Treatment responsive brain tumors can appear similar to non-responsive tumors on conventional anatomical MR images, earlier in the therapy, leading to a poor prognosis for many patients. Biomarkers such as lactate are particularly of interest in the oncological studies of solid tumors to determine their energy metabolism, blood flow, and hypoxia. Despite the capability of nearly all clinical MRI scanners to perform MRSI only limited integration of MRSI into routine clinical studies has occurred to date. The major challenges affecting its true potential are the inherently long acquisition time, low signal-to-noise (SNR) of the signals, overlapping of spectral lines, or the presence of artifacts. The goal of this dissertation work is to facilitate MRSI in routine clinical studies without affecting the current patient throughput. In this work, the Compressed Sensing (CS) strategy was used to accelerate conventional Point RESolved Spectroscopy (PRESS) MRSI by sampling well below the Shannon-Nyquist limit. Two undersampling strategies, namely the pseudo-random variable density and a novel a priori method was developed and implemented on a clinical scanner. Prospectively undersampled MRSI data was acquired from patients with various brain-related concerns. Spatial-spectral post-processing and CS reconstruction pipeline was developed for multi-channel undersampled data. The fidelity of the CS-MRSI method was determined by comparing the CS reconstructed data to the fully sampled data. Statistical results showed that the a priori approach maintained high spectral fidelity compared to the fully sampled reference for an 80% reduction in scan time. Next, an improvement to the CS-MRSI reconstruction was achieved by incorporating coil sensitivity maps as support in the iterative process. Further, a CS-MRSI-based fast lactate spectroscopic imaging method was developed and implemented to achieve complete water and fat suppression for accurate spatial localization and quantification of lactate in tumors. In vitro phantoms were developed, and the sequence was tested to determine the efficacy of CS-MRSI for low SNR signals, the efficacy of the CS acceleration was determined with statistical analysis.
ContributorsBikkamane Jayadev, Nutandev (Author) / Kodibagkar, Vikram (Thesis advisor) / Chang, John (Committee member) / Robison, Ryan (Committee member) / Smith, Barbara (Committee member) / Sohn, Sung-Min (Committee member) / Arizona State University (Publisher)
Created2021
165040-Thumbnail Image.png
Description
The ability of magnetic resonance imaging (MRI) to image any part of the human body without the effects of harmful radiation such as in CAT and PET scans established MRI as a clinical mainstay for a variety of different ailments and maladies. Short wavelengths accompany the high frequencies present in

The ability of magnetic resonance imaging (MRI) to image any part of the human body without the effects of harmful radiation such as in CAT and PET scans established MRI as a clinical mainstay for a variety of different ailments and maladies. Short wavelengths accompany the high frequencies present in high-field MRI, and are on the same scale as the human body at a static magnetic field strength of 3 T (128 MHz). As a result of these shorter wavelengths, standing wave effects are produced in the MR bore where the patient is located. These standing waves generate bright and dark spots in the resulting MR image, which correspond to irregular regions of high and low clarity. Coil loading is also an inevitable byproduct of subject positioning inside the bore, which decreases the signal that the region of interest (ROI) receives for the same input power. Several remedies have been proposed in the literature to remedy the standing wave effect, including the placement of high permittivity dielectric pads (HPDPs) near the ROI. Despite the success of HPDPs at smoothing out image brightness, these pads are traditionally bulky and take up a large spatial volume inside the already small MR bore. In recent years, artificial periodic structures known as metamaterials have been designed to exhibit specific electromagnetic effects when placed inside the bore. Although typically thinner than HPDPs, many metamaterials in the literature are rigid and cannot conform to the shape of the patient, and some are still too bulky for practical use in clinical settings. The well-known antenna engineering concept of fractalization, or the introduction of self-similar patterns, may be introduced to the metamaterial to display a specific resonance curve as well as increase the metamaterial’s intrinsic capacitance. Proposed in this paper is a flexible fractal-inspired metamaterial for application in 3 T MR head imaging. To demonstrate the advantages of this flexibility, two different metamaterial configurations are compared to determine which produces a higher localized signal-to-noise ratio (SNR) and average signal measured in the image: in the first configuration, the metamaterial is kept rigid underneath a human head phantom to represent metamaterials in the literature (single-sided placement); and in the second, the metamaterial is wrapped around the phantom to utilize its flexibility (double-sided placement). The double-sided metamaterial setup was found to produce an increase in normalized SNR of over 5% increase in five of six chosen ROIs when compared to no metamaterial use and showed a 10.14% increase in the total average signal compared to the single-sided configuration.
ContributorsSokol, Samantha (Author) / Sohn, Sung-Min (Thesis director) / Allee, David (Committee member) / Jones, Anne (Committee member) / Barrett, The Honors College (Contributor) / Electrical Engineering Program (Contributor)
Created2022-05
190874-Thumbnail Image.png
Description
Magnetic Resonance Imaging has become an increasingly reliable source of medical imaging to obtain high quality detailed images of the human anatomy. Application specific coil or an array of coils when placed closely to the anatomy produces high quality image due to the improved spatial signal to noise ratio. Elastic

Magnetic Resonance Imaging has become an increasingly reliable source of medical imaging to obtain high quality detailed images of the human anatomy. Application specific coil or an array of coils when placed closely to the anatomy produces high quality image due to the improved spatial signal to noise ratio. Elastic RF coils have been shown to conform to the shape of the patient’s body and drastically reduce the gap between coil and anatomy. First, a major challenge faced by these elastic RF coils is the changing impedance condition as the coil takes a different shape for every individual. Next, an area that could benefit from the improved image quality and patient comfort that comes from flexible RF coil design is endorectal prostate imaging. Demonstrated in the first part of this dissertation is a modular solution to compensate the impedance mismatch. Standalone Wireless Impedance Matching (SWIM) system is an automatic impedance mismatch compensation system that can function independently of the MR scanner. The matching network consists of a capacitor array with RF switches to electronically cycle through different input impedance conditions. The SWIM system can automatically calibrate an RF coil in 3s with a reflection coefficient of less than -15dB resulting in improved Signal-to-noise ratio (SNR) of the sample image by 12% - 24%, based on sample size, when compared to a loaded coil without retuning. For the second part, we propose a novel elastic and inflatable RF coil integrated with the SWIM system for endorectal prostate imaging at 9.4T. A silicone polymer substrate filled with liquid metal alloy is designed and fabricated with a cavity to create ii inflation. This inflatable RF coil is combined with the SWIM system to automatically tune and match after inflating the RF coil for individual levels of inflation. The imaging results have shown a ~10%, ~19%, and ~25 % increase in SNR due to inflation of RF coil at different ROIs in the acquired image. Overall, the methods proposed and discussed in this thesis are a step towards a new generation of RF coil systems for both existing applications and upcoming ones.
ContributorsKandala, Sri Kirthi (Author) / Sohn, Sung-Min (Thesis advisor) / Kdibagkar, Vikram (Committee member) / Sadleir, Rosalind J (Committee member) / Beeman, Scott (Committee member) / Trichopoulos, Georgios (Committee member) / Arizona State University (Publisher)