Matching Items (5)
Filtering by

Clear all filters

136778-Thumbnail Image.png
Description
The Honors Thesis involved the use of vertically-aligned, piezoelectric nanowire sensor arrays configured by Dr. Henry A. Sodano and Dr. Aneesh Koka from the University of Florida, in order to acquire acceleration data. Originally, the project was focused on interfacing and calibrating the barium titanate (BaTio3) sensors to measure wall

The Honors Thesis involved the use of vertically-aligned, piezoelectric nanowire sensor arrays configured by Dr. Henry A. Sodano and Dr. Aneesh Koka from the University of Florida, in order to acquire acceleration data. Originally, the project was focused on interfacing and calibrating the barium titanate (BaTio3) sensors to measure wall shear stress, a fluid dynamic characteristic. In order to gain an understanding of these novel piezoelectric sensors, the experiments performed by Sodano and Koka were to be investigated, replicated, and results reproduced. After initial trial phases, signals failed to be consistently measured from the sensors and the project's emphasis was re-defined. The outlined goals were 1) to re-design the initial system used for signal acquisition, 2) test the improved signal acquisition system, 3) successfully measure output signals from the BaTiO3 nanowire sensors, and 4) determine the cause for inconsistent signal measurements from the piezoelectric nanawire sensors. Following a detailed review of the previous experimental procedures and the initial signal acquisition system, an improved acquisition system was designed and its expected behavior was tested and verified. Despite the introduction of the improved acquisition system, voltage outputs were unable to be measured as a function of shaker table acceleration. It was impossible to verify the effect of the improved signal acquisition system on the measured BaTiO3 nanowire sensor output. Based on an analysis of data collected using a commercial 3-axis acceleromoeter, it is hypothesized that the BaTiO3 nanowire sensors were broken after the first experimental trial due to an excessively applied force from an external source (i.e. shaker table, improper handling during experimentation, and/or improper handling during transportation).
ContributorsThomas, Jonah (Author) / Frakes, David (Thesis director) / LaBelle, Jeffrey (Contributor) / Barrett, The Honors College (Contributor)
Created2014-05
136798-Thumbnail Image.png
Description
The purpose of this project was to examine the viability of protein biomarkers in pre-symptomatic detection of lung cancer. Regular screening has been shown to vastly improve patient survival outcome. Lung cancer currently has the highest occurrence and mortality of all cancers and so a means of screening would be

The purpose of this project was to examine the viability of protein biomarkers in pre-symptomatic detection of lung cancer. Regular screening has been shown to vastly improve patient survival outcome. Lung cancer currently has the highest occurrence and mortality of all cancers and so a means of screening would be highly beneficial. In this research, the biomarker neuron-specific enolase (Enolase-2, eno2), a marker of small-cell lung cancer, was detected at varying concentrations using electrochemical impedance spectroscopy in order to develop a mathematical model of predicting protein expression based on a measured impedance value at a determined optimum frequency. The extent of protein expression would indicate the possibility of the patient having small-cell lung cancer. The optimum frequency was found to be 459 Hz, and the mathematical model to determine eno2 concentration based on impedance was found to be y = 40.246x + 719.5 with an R2 value of 0.82237. These results suggest that this approach could provide an option for the development of small-cell lung cancer screening utilizing electrochemical technology.
ContributorsEvans, William Ian (Author) / LaBelle, Jeffrey (Thesis director) / Spano, Mark (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
136374-Thumbnail Image.png
Description
The Baby Friendly Hospital Initiative (BFHI) was created in 1991 with the goal to provide support and education to mothers on breastfeeding in order to increase the rate and duration of breastfeeding across the world. Despite being around for over 20 years, it has only been successfully incorporated into 245

The Baby Friendly Hospital Initiative (BFHI) was created in 1991 with the goal to provide support and education to mothers on breastfeeding in order to increase the rate and duration of breastfeeding across the world. Despite being around for over 20 years, it has only been successfully incorporated into 245 hospitals in the United States as of 2015. Due to the many benefits this initiative brings to mothers, infants, and the hospitals themselves as well as being shown to increase the incidence, duration, and exclusivity of breastfeeding, the goal of this project was to create a mother friendly brochure sharing this. The brochure was created in order to spread the word of the BFHI to expecting mothers so that they are informed and able to use this information to not only improve their own child-birthing experience but also push for implementation in their delivering facilities. The brochure covers additional topics such as breastfeeding benefits and tips, lactation resources, and steps to incorporate into their own hospital stay if outside of a BFHI facility in order to get a few of the benefits that the Baby Friendly Initiative provides. The brochure was tested for clarity, effectiveness, and for overall reactions in a study conducted at a local women's clinic surveying expectant mothers through the use of a short survey. These results were used to make minor improvements to the brochure before moving on to plans of how to disseminate the brochure to more clinics within the Phoenix area. The dissemination of this brochure will share this important information with women of childbearing age and hopefully lead to greater knowledge and progress towards improved maternal and neonatal outcomes.
ContributorsGunnare, Chrystina Jean (Author) / Whisner, Corrie (Thesis director) / Bever, Jennie (Committee member) / Barrett, The Honors College (Contributor) / School of Nutrition and Health Promotion (Contributor)
Created2015-05
134280-Thumbnail Image.png
Description
As of today, there does not exist a cheap diagnostic for lactate for use in trauma centers. $671 billion are spent on trauma accidents and emergency rooms, with money focused on treatments such as YSI and ELISA, costing $1500 and $200, respectively. Gold disk electrodes were used to immobilize lactate

As of today, there does not exist a cheap diagnostic for lactate for use in trauma centers. $671 billion are spent on trauma accidents and emergency rooms, with money focused on treatments such as YSI and ELISA, costing $1500 and $200, respectively. Gold disk electrodes were used to immobilize lactate dehydrogenase and glucose oxidase, with electrochemical impedance spectroscopy (EIS) used as the method for detection. Two lactate experimental runs were completed with data detailing a linear model and positive correlation for imaginary impedance and concentration, and one glucose experimental run was completed proving that a continuous system can be completed accounting for reaction and consumption using EIS, a process previously not done before.
ContributorsEltohamy, Omar Khaled (Author) / LaBelle, Jeffrey (Thesis director) / Lin, Chi-En (Committee member) / Harrington Bioengineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2017-05
137680-Thumbnail Image.png
Description
Intracranial aneurysms, which form in the blood vessels of the brain, are particularly dangerous because of the importance and fragility of the human brain. When an intracranial aneurysm gets large it poses a significant risk of bursting and causing subarachnoid hemorrhaging (SAH), a possibly fatal condition. One possible treatment involves

Intracranial aneurysms, which form in the blood vessels of the brain, are particularly dangerous because of the importance and fragility of the human brain. When an intracranial aneurysm gets large it poses a significant risk of bursting and causing subarachnoid hemorrhaging (SAH), a possibly fatal condition. One possible treatment involves placing a stent in the vessel to act as a flow diverter. In this study we look at the hemodynamics of two geometries of idealized basilar tip aneurysms, at 2,3, and 4 ml/s pulsatile flow, at three different points in the cardiac cycle. The smaller model had neck and dome diameters of 2.67 mm and 4 mm respectively, while the larger aneurysm had neck and dome diameters of 3 mm and 6 mm respectively. Both diameters and the dome to neck ratio increased in the second model, representing growth over time. Flow was analyzed using stereoscopic particle image velocimetry (PIV) for both geometries in untreated models, as well as after treatment with a high porosity Enterprise stent (Codman and Shurtleff Inc.). Flow in the models was characterized by root mean square velocity in the aneurysm and neck plane, cross neck flow, max aneurysm vorticity, and total aneurysm kinetic energy. It was found that in the smaller aneurysm model (model 1), Enterprise stent treatment reduced all flow parameters substantially. The smallest reduction was in max vorticity, at 42.48%, and the largest in total kinetic energy, at 75.69%. In the larger model (model 2) there was a 52.18% reduction in cross neck flow, but a 167.28% increase in aneurysm vorticity. The other three parameters experienced little change. These results, along with observed velocity vector fields, indicate a noticeable diversion of flow away from the aneurysm in the stent treated model 1. Treatment in model 2 had a small flow diversion effect, but also altered flow in unpredictable ways, in some cases having a detrimental effect on aneurysm hemodynamics. The results of this study indicate that Enterprise stent treatment is only effective in small, relatively undeveloped aneurysm geometries, and waiting until an aneurysm has grown too large can eliminate this treatment option altogether.
ContributorsLindsay, James Bryan (Author) / Frakes, David (Thesis director) / LaBelle, Jeffrey (Committee member) / Nair, Priya (Committee member) / Barrett, The Honors College (Contributor) / School of Humanities, Arts, and Cultural Studies (Contributor)
Created2013-05