Matching Items (42)
Filtering by

Clear all filters

156398-Thumbnail Image.png
Description
Human locomotion is an essential function that enables individuals to lead healthy, independent lives. One important feature of natural walking is the capacity to transition across varying surfaces, enabling an individual to traverse complex terrains while maintaining balance. There has been extensive work regarding improving prostheses' performance in changing walking

Human locomotion is an essential function that enables individuals to lead healthy, independent lives. One important feature of natural walking is the capacity to transition across varying surfaces, enabling an individual to traverse complex terrains while maintaining balance. There has been extensive work regarding improving prostheses' performance in changing walking conditions, but there is still a need to address the transition from rigid to compliant or dynamic surfaces, such as the transition from pavement to long grass or soft sand. This research aims to investigate the mechanisms involved such transitions and identify potential indicators of the anticipated change that can be applied to the control of a powered ankle prosthetic to reduce falls and improve stability in lower-limb amputees in a wider range of walking environments. A series of human subject experiments were conducted using the Variable Stiffness Treadmill (VST) to control walking surface compliance while gait kinematics and muscular activation data were collected from three healthy, nondisabled subjects. Specifically, the kinematics and electromyography (EMG) profiles of the gait cycles immediately preceding and following an expected change in surface compliance were compared to that of normal, rigid surface walking. While the results do not indicate statistical differences in the EMG profiles between the two modes of walking, the muscle activation appears to be qualitatively different from inspection of the data. Additionally, there were promising statistically significant changes in joint angles, especially in observed increases in hip flexion during the swing phases both before and during an expected change in surface. Decreases in ankle flexion immediately before heel strike on the perturbed leg were also observed to occur simultaneously with decreases in tibialis anterior (TA) muscle activation, which encourages additional research investigating potential changes in EMG profiles. Ultimately, more work should be done to make strong conclusions about potential indicators of walking surface transitions, but this research demonstrates the potential of EMG and kinematic data to be used in the control of a powered ankle prosthetic.
ContributorsFou, Linda (Author) / Artemiadis, Panagiotis (Thesis advisor) / Lee, Hyunglae (Committee member) / Polygerinos, Panagiotis (Committee member) / Arizona State University (Publisher)
Created2018
156496-Thumbnail Image.png
Description
Soft Poly-Limb (SPL) is a pneumatically driven, wearable, soft continuum robotic arm designed to aid humans with medical conditions, such as cerebral palsy, paraplegia, cervical spondylotic myelopathy, perform activities of daily living. To support user's tasks, the SPL acts as an additional limb extending from the human body which can

Soft Poly-Limb (SPL) is a pneumatically driven, wearable, soft continuum robotic arm designed to aid humans with medical conditions, such as cerebral palsy, paraplegia, cervical spondylotic myelopathy, perform activities of daily living. To support user's tasks, the SPL acts as an additional limb extending from the human body which can be controlled to perform safe and compliant mobile manipulation in three-dimensional space. The SPL is inspired by invertebrate limbs, such as the elephant trunk and the arms of the octopus. In this work, various geometrical and physical parameters of the SPL are identified, and behavior of the actuators that comprise it are studied by varying their parameters through novel quasi-static computational models. As a result, this study provides a set of engineering design rules to create soft actuators for continuum soft robotic arms by understanding how varying parameters affect the actuator's motion as a function of the input pressure. A prototype of the SPL is fabricated to analyze the accuracy of these computational models by performing linear expansion, bending and arbitrary pose tests. Furthermore, combinations of the parameters based on the application of the SPL are determined to affect the weight, payload capacity, and stiffness of the arm. Experimental results demonstrate the accuracy of the proposed computational models and help in understanding the behavior of soft compliant actuators. Finally, based on the set functional requirements for the assistance of impaired users, results show the effectiveness of the SPL in performing tasks for activities of daily living.
ContributorsNuthi, Sai Gautham (Author) / Polygerinos, Panagiotis (Thesis advisor) / Lee, Hyunglae (Committee member) / Yong, Sze Zheng (Committee member) / Arizona State University (Publisher)
Created2018
156724-Thumbnail Image.png
Description
The world population is aging. Age-related disorders such as stroke and spinal cord injury are increasing rapidly, and such patients often suffer from mobility impairment. Wearable robotic exoskeletons are developed that serve as rehabilitation devices for these patients. In this thesis, a knee exoskeleton design with higher torque output compared

The world population is aging. Age-related disorders such as stroke and spinal cord injury are increasing rapidly, and such patients often suffer from mobility impairment. Wearable robotic exoskeletons are developed that serve as rehabilitation devices for these patients. In this thesis, a knee exoskeleton design with higher torque output compared to the first version, is designed and fabricated.

A series elastic actuator is one of the many actuation mechanisms employed in exoskeletons. In this mechanism a torsion spring is used between the actuator and human joint. It serves as torque sensor and energy buffer, making it compact and

safe.

A version of knee exoskeleton was developed using the SEA mechanism. It uses worm gear and spur gear combination to amplify the assistive torque generated from the DC motor. It weighs 1.57 kg and provides a maximum assistive torque of 11.26 N·m. It can be used as a rehabilitation device for patients affected with knee joint impairment.

A new version of exoskeleton design is proposed as an improvement over the first version. It consists of components such as brushless DC motor and planetary gear that are selected to meet the design requirements and biomechanical considerations. All the other components such as bevel gear and torsion spring are selected to be compatible with the exoskeleton. The frame of the exoskeleton is modeled in SolidWorks to be modular and easy to assemble. It is fabricated using sheet metal aluminum. It is designed to provide a maximum assistive torque of 23 N·m, two times over the present exoskeleton. A simple brace is 3D printed, making it easy to wear and use. It weighs 2.4 kg.

The exoskeleton is equipped with encoders that are used to measure spring deflection and motor angle. They act as sensors for precise control of the exoskeleton.

An impedance-based control is implemented using NI MyRIO, a FPGA based controller. The motor is controlled using a motor driver and powered using an external battery source. The bench tests and walking tests are presented. The new version of exoskeleton is compared with first version and state of the art devices.
ContributorsJhawar, Vaibhav (Author) / Zhang, Wenlong (Thesis advisor) / Sugar, Thomas G. (Committee member) / Lee, Hyunglae (Committee member) / Marvi, Hamidreza (Committee member) / Arizona State University (Publisher)
Created2018
157143-Thumbnail Image.png
Description
The Basilisk lizard is known for its agile locomotion capabilities on granular and aquatic media making it an impressive model organism for studying multi-terrain locomotion mechanics. The work presented here is aimed at understanding locomotion characteristics of Basilisk lizards through a systematic series of robotic and animal experiments. In this

The Basilisk lizard is known for its agile locomotion capabilities on granular and aquatic media making it an impressive model organism for studying multi-terrain locomotion mechanics. The work presented here is aimed at understanding locomotion characteristics of Basilisk lizards through a systematic series of robotic and animal experiments. In this work, a Basilisk lizard inspired legged robot with bipedal and quadrupedal locomotion capabilities is presented. A series of robot experiments are conducted on dry and wet (saturated) granular media to determine the effects of gait parameters and substrate saturation, on robot velocity and energetics. Gait parameters studied here are stride frequency and stride length. Results of robot experiments are compared with previously obtained animal data. It is observed that for a fixed robot stride frequency, velocity and stride length increase with increasing saturation, confirming the locomotion characteristics of the Basilisk lizard. It is further observed that with increasing saturation level, robot cost of transport decreases. An identical series of robot experiments are performed with quadrupedal gait to determine effects of gait parameters on robot performance. Generally, energetics of bipedal running is observed to be higher than quadrupedal operation. Experimental results also reveal how gait parameters can be varied to achieve different desired velocities depending on the substrate saturation level. In addition to robot experiments on granular media, a series of animal experiments are conducted to determine and characterize strategies

exhibited by Basilisk lizards when transitioning from granular to aquatic media.
ContributorsJayanetti, Vidu (Author) / Marvi, Hamid (Thesis advisor) / Emady, Heather (Committee member) / Lee, Hyunglae (Committee member) / Arizona State University (Publisher)
Created2018
Description
For a conventional quadcopter system with 4 planar rotors, flight times vary between 10 to 20 minutes depending on the weight of the quadcopter and the size of the battery used. In order to increase the flight time, either the weight of the quadcopter should be reduced or the battery

For a conventional quadcopter system with 4 planar rotors, flight times vary between 10 to 20 minutes depending on the weight of the quadcopter and the size of the battery used. In order to increase the flight time, either the weight of the quadcopter should be reduced or the battery size should be increased. Another way is to increase the efficiency of the propellers. Previous research shows that ducting a propeller can cause an increase of up to 94 % in the thrust produced by the rotor-duct system. This research focused on developing and testing a quadcopter having a centrally ducted rotor which produces 60 % of the total system thrust and 3 other peripheral rotors. This quadcopter will provide longer flight times while having the same maneuvering flexibility in planar movements.
ContributorsLal, Harsh (Author) / Artemiadis, Panagiotis (Thesis advisor) / Lee, Hyunglae (Committee member) / Zhang, Wenlong (Committee member) / Arizona State University (Publisher)
Created2019
156950-Thumbnail Image.png
Description
Wearable robotics has gained huge popularity in recent years due to its wide applications in rehabilitation, military, and industrial fields. The weakness of the skeletal muscles in the aging population and neurological injuries such as stroke and spinal cord injuries seriously limit the abilities of these individuals to perform daily

Wearable robotics has gained huge popularity in recent years due to its wide applications in rehabilitation, military, and industrial fields. The weakness of the skeletal muscles in the aging population and neurological injuries such as stroke and spinal cord injuries seriously limit the abilities of these individuals to perform daily activities. Therefore, there is an increasing attention in the development of wearable robots to assist the elderly and patients with disabilities for motion assistance and rehabilitation. In military and industrial sectors, wearable robots can increase the productivity of workers and soldiers. It is important for the wearable robots to maintain smooth interaction with the user while evolving in complex environments with minimum effort from the user. Therefore, the recognition of the user's activities such as walking or jogging in real time becomes essential to provide appropriate assistance based on the activity.

This dissertation proposes two real-time human activity recognition algorithms intelligent fuzzy inference (IFI) algorithm and Amplitude omega ($A \omega$) algorithm to identify the human activities, i.e., stationary and locomotion activities. The IFI algorithm uses knee angle and ground contact forces (GCFs) measurements from four inertial measurement units (IMUs) and a pair of smart shoes. Whereas, the $A \omega$ algorithm is based on thigh angle measurements from a single IMU.

This dissertation also attempts to address the problem of online tuning of virtual impedance for an assistive robot based on real-time gait and activity measurement data to personalize the assistance for different users. An automatic impedance tuning (AIT) approach is presented for a knee assistive device (KAD) in which the IFI algorithm is used for real-time activity measurements. This dissertation also proposes an adaptive oscillator method known as amplitude omega adaptive oscillator ($A\omega AO$) method for HeSA (hip exoskeleton for superior augmentation) to provide bilateral hip assistance during human locomotion activities. The $A \omega$ algorithm is integrated into the adaptive oscillator method to make the approach robust for different locomotion activities. Experiments are performed on healthy subjects to validate the efficacy of the human activities recognition algorithms and control strategies proposed in this dissertation. Both the activity recognition algorithms exhibited higher classification accuracy with less update time. The results of AIT demonstrated that the KAD assistive torque was smoother and EMG signal of Vastus Medialis is reduced, compared to constant impedance and finite state machine approaches. The $A\omega AO$ method showed real-time learning of the locomotion activities signals for three healthy subjects while wearing HeSA. To understand the influence of the assistive devices on the inherent dynamic gait stability of the human, stability analysis is performed. For this, the stability metrics derived from dynamical systems theory are used to evaluate unilateral knee assistance applied to the healthy participants.
ContributorsChinimilli, Prudhvi Tej (Author) / Redkar, Sangram (Thesis advisor) / Zhang, Wenlong (Thesis advisor) / Sugar, Thomas G. (Committee member) / Lee, Hyunglae (Committee member) / Marvi, Hamidreza (Committee member) / Arizona State University (Publisher)
Created2018
156718-Thumbnail Image.png
Description
Lower-limb wearable assistive robots could alter the users gait kinematics by inputting external power, which can be interpreted as mechanical perturbation to subject normal gait. The change in kinematics may affect the dynamic stability. This work attempts to understand the effects of different physical assistance from these robots on the

Lower-limb wearable assistive robots could alter the users gait kinematics by inputting external power, which can be interpreted as mechanical perturbation to subject normal gait. The change in kinematics may affect the dynamic stability. This work attempts to understand the effects of different physical assistance from these robots on the gait dynamic stability.

A knee exoskeleton and ankle assistive device (Robotic Shoe) are developed and used to provide walking assistance. The knee exoskeleton provides personalized knee joint assistive torque during the stance phase. The robotic shoe is a light-weighted mechanism that can store the potential energy at heel strike and release it by using an active locking mechanism at the terminal stance phase to provide push-up ankle torque and assist the toe-off. Lower-limb Kinematic time series data are collected for subjects wearing these devices in the passive and active mode. The changes of kinematics with and without these devices on lower-limb motion are first studied. Orbital stability, as one of the commonly used measure to quantify gait stability through calculating Floquet Multipliers (FM), is employed to asses the effects of these wearable devices on gait stability. It is shown that wearing the passive knee exoskeleton causes less orbitally stable gait for users, while the knee joint active assistance improves the orbital stability compared to passive mode. The robotic shoe only affects the targeted joint (right ankle) kinematics, and wearing the passive mechanism significantly increases the ankle joint FM values, which indicates less walking orbital stability. More analysis is done on a mechanically perturbed walking public data set, to show that orbital stability can quantify the effects of external mechanical perturbation on gait dynamic stability. This method can further be used as a control design tool to ensure gait stability for users of lower-limb assistive devices.
ContributorsRezayat Sorkhabadi, Seyed Mostafa (Author) / Zhang, Wenlong (Thesis advisor) / Lee, Hyunglae (Committee member) / Artemiadis, Panagiotis (Committee member) / Arizona State University (Publisher)
Created2018
136487-Thumbnail Image.png
Description
Robotic rehabilitation for upper limb post-stroke recovery is a developing technology. However, there are major issues in the implementation of this type of rehabilitation, issues which decrease efficacy. Two of the major solutions currently being explored to the upper limb post-stroke rehabilitation problem are the use of socially assistive rehabilitative

Robotic rehabilitation for upper limb post-stroke recovery is a developing technology. However, there are major issues in the implementation of this type of rehabilitation, issues which decrease efficacy. Two of the major solutions currently being explored to the upper limb post-stroke rehabilitation problem are the use of socially assistive rehabilitative robots, robots which directly interact with patients, and the use of exoskeleton-based systems of rehabilitation. While there is great promise in both of these techniques, they currently lack sufficient efficacy to objectively justify their costs. The overall efficacy to both of these techniques is about the same as conventional therapy, yet each has higher overhead costs that conventional therapy does. However there are associated long-term cost savings in each case, meaning that the actual current viability of either of these techniques is somewhat nebulous. In both cases, the problems which decrease technique viability are largely related to joint action, the interaction between robot and human in completing specific tasks, and issues in robot adaptability that make joint action difficult. As such, the largest part of current research into rehabilitative robotics aims to make robots behave in more "human-like" manners or to bypass the joint action problem entirely.
ContributorsRamakrishna, Vijay Kambhampati (Author) / Helms Tillery, Stephen (Thesis director) / Buneo, Christopher (Committee member) / Barrett, The Honors College (Contributor) / Economics Program in CLAS (Contributor) / W. P. Carey School of Business (Contributor) / School of Life Sciences (Contributor)
Created2015-05
137299-Thumbnail Image.png
Description
This thesis focused on grasping tasks with the goal of investigating, analyzing, and quantifying human catching trends by way of a mathematical model. The aim of this project was to study human trends in a dynamic grasping task (catching a rolling ball), relate those discovered trends to kinematic characteristics of

This thesis focused on grasping tasks with the goal of investigating, analyzing, and quantifying human catching trends by way of a mathematical model. The aim of this project was to study human trends in a dynamic grasping task (catching a rolling ball), relate those discovered trends to kinematic characteristics of the object, and use this relation to control a robot hand in real time. As an ultimate goal, it was hoped that this research will aide in furthering the bio-inspiration in robot control methods. To achieve the above goal, firstly a tactile sensing glove was developed. This instrument allowed for in depth study of human reactionary grasping movements when worn by subjects during experimentation. This sensing glove system recorded force data from the palm and motion data from four fingers. From these data sets, temporal trends were established relating to when subjects initiated grasping during each trial. Moreover, optical tracking was implemented to study the kinematics of the moving object during human experiments and also to close the loop during the control of the robot hand. Ultimately, a mathematical bio-inspired model was created. This was embodied in a two-term decreasing power function which related the temporal trend of wait time to the ball initial acceleration. The wait time is defined as the time between when the experimental conductor releases the ball and when the subject begins to initiate grasping by closing their fingers, over a distance of four feet. The initial acceleration is the first acceleration value of the object due to the force provided when the conductor throws the object. The distance over which the ball was thrown was incorporated into the model. This is discussed in depth within the thesis. Overall, the results presented here show promise for bio-inspired control schemes in the successful application of robotic devices. This control methodology will ideally be developed to move robotic prosthesis past discrete tasks and into more complicated activities.
ContributorsCard, Dillon (Co-author) / Mincieli, Jennifer (Co-author) / Artemiadis, Panagiotis (Thesis director) / Santos, Veronica (Committee member) / Middleton, James (Committee member) / Barrett, The Honors College (Contributor) / School of Sustainability (Contributor) / Mechanical and Aerospace Engineering Program (Contributor) / W. P. Carey School of Business (Contributor)
Created2014-05
134393-Thumbnail Image.png
Description
Walking ability is a complex process that is essential to humans, critical for performing a range of everyday tasks and enables a healthy, independent lifestyle. Human gait has evolved to be robust, adapting to a wide range of external stimuli, including variable walking surface compliance. Unfortunately, many people suffer from

Walking ability is a complex process that is essential to humans, critical for performing a range of everyday tasks and enables a healthy, independent lifestyle. Human gait has evolved to be robust, adapting to a wide range of external stimuli, including variable walking surface compliance. Unfortunately, many people suffer from impaired gait as a result of conditions such as stroke. For these individuals, recovering their gait is a priority and a challenge. The ASU Variable Stiffness Treadmill (VST) is a device that is able to the change its surface compliance through its unique variable stiffness mechanism. By doing this, the VST can be used to investigate gait and has potential as a rehabilitation tool. The objective of this research is to design a variable damping mechanism for the VST, which addresses the need to control effective surface damping, the only form of mechanical impedance that the VST does not currently control. Thus, this project will contribute toward the development of the Variable Impedance Treadmill (VIT), which will encompass a wider range of variable surface compliance and enable all forms of impedance to be con- trolled for the first time. To achieve this, the final design of the mechanism will employ eddy current damping using several permanent magnets mounted to the treadmill and a large copper plate stationed on the ground. Variable damping is obtained by using lead screw mechanisms to remove magnets from acting on the copper plate, which effectively eliminates their effect on damping and changes the overall treadmill surface damping. Results from experimentation validate the mechanism's ability to provide variable damping to the VST. A model for effective surface damping is generated based on open-loop characterization experiments and is generalized for future experimental setups. Overall, this project progresses to the development of the VIT and has potential applications in walking surface simulation, gait investigation, and robot-assisted rehabilitation technology.
ContributorsFou, Linda Guo (Author) / Artemiadis, Panagiotis (Thesis director) / Lee, Hyunglae (Committee member) / Mechanical and Aerospace Engineering Program (Contributor, Contributor) / School of Mathematical and Statistical Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2017-05