Matching Items (8)
Filtering by

Clear all filters

153159-Thumbnail Image.png
Description
This thesis is a study of Bandwidth limitation of basestation power amplifier and its Doherty application. Fundamentally, bandwidth of a power amplifier (PA) is limited by both its input and output prematch networks and its Doherty architecture, specifically the impedance inverter between the main and auxiliary amplifier. In this study,

This thesis is a study of Bandwidth limitation of basestation power amplifier and its Doherty application. Fundamentally, bandwidth of a power amplifier (PA) is limited by both its input and output prematch networks and its Doherty architecture, specifically the impedance inverter between the main and auxiliary amplifier. In this study, only the output prematch network and the Doherty architecture follows are being investigated. A new proposed impedance inverter in the Doherty architecture exhibits an extended bandwidth compared to traditional quarterwave line.

Base on the loadline analysis, output impedance of the power amplifier can be represented by a loadline resistor and an output shunt capacitor. Base on this simple model, the maximum allowed bandwidth of the output impedance of the power amplifier can be estimated using the Bode-Fano method. However, since power amplifier is in fact nonlinear, harmonic balance simulation is used to loadpull the device across a broad range of frequencies. Base on the simulated large signal impedance at maximum power, the prematch circuitry can be designed. On a system level, the prematch power amplifier is used in Doherty amplifier. Two different prematch circuitries, T- section and shunt L methods are investigated along with their comparison in the Doherty architecture at both back off power and peak power condition. The last section of the thesis will be incorporating the proposed impedance inverter structure between the main and auxiliary amplifiers.

The simulated results showed the shunt L prematch topology has the least impedance dispersion across frequency. Along with the new impedance inverter structure, the 65% efficiency bandwidth improves by 50% compared to the original impedance inverter structure at back off power level.
ContributorsYang, Nick (Author) / Pan, George (Committee member) / Aberle, James T (Committee member) / Yu, Hongyu (Committee member) / Arizona State University (Publisher)
Created2014
150240-Thumbnail Image.png
Description
This thesis investigated two different thermal flow sensors for intravascular shear stress analysis. They were based on heat transfer principle, which heat convection from the resistively heated element to the flowing fluid was measured as a function of the changes in voltage. For both sensors, the resistively heated elements were

This thesis investigated two different thermal flow sensors for intravascular shear stress analysis. They were based on heat transfer principle, which heat convection from the resistively heated element to the flowing fluid was measured as a function of the changes in voltage. For both sensors, the resistively heated elements were made of Ti/Pt strips with the thickness 0.12 µm and 0.02 µm. The resistance of the sensing element was measured at approximately 1.6-1.7 kohms;. A linear relation between the resistance and temperature was established over the temperature ranging from 22 degree Celsius to 80 degree Celsius and the temperature coefficient of resistance (TCR) was at approximately 0.12 %/degree Celsius. The first thermal flow sensor was one-dimensional (1-D) flexible shear stress sensor. The structure was sensing element sandwiched by a biocompatible polymer "poly-para-xylylene", also known as Parylene, which provided both insulation of electrodes and flexibility of the sensors. A constant-temperature (CT) circuit was designed as the read out circuit based on 0.6 µm CMOS (Complementary metal-oxide-semiconductor) process. The 1-D shear stress sensor suffered from a large measurement error. Because when the sensor was inserted into blood vessels, it was impossible to mount the sensor to the wall as calibrated in micro fluidic channels. According to the previous simulation work, the shear stress was varying and the sensor itself changed the shear stress distribution. We proposed a three-dimensional (3-D) thermal flow sensor, with three-axis of sensing elements integrated in one sensor. It was in the similar shape as a hexagonal prism with diagonal of 1000 µm. On the top of the sensor, there were five bond pads for external wires over 500 µm thick silicon substrate. In each nonadjacent side surface, there was a bended parylene branch with one sensing element. Based on the unique 3-D structure, the sensor was able to obtain data along three axes. With computational fluid dynamics (CFD) model, it is possible to locate the sensor in the blood vessels and give us a better understanding of shear stress distribution in the presence of time-varying component of blood flow and realize more accurate assessment of intravascular convective heat transfer.
ContributorsTang, Rui (Author) / Yu, Hongyu (Thesis advisor) / Jiang, Hanqing (Committee member) / Pan, George (Committee member) / Arizona State University (Publisher)
Created2011
149852-Thumbnail Image.png
Description
Negative bias temperature instability (NBTI) and channel hot carrier (CHC) are important reliability issues impacting analog circuit performance and lifetime. Compact reliability models and efficient simulation methods are essential for circuit level reliability prediction. This work proposes a set of compact models of NBTI and CHC effects for analog and

Negative bias temperature instability (NBTI) and channel hot carrier (CHC) are important reliability issues impacting analog circuit performance and lifetime. Compact reliability models and efficient simulation methods are essential for circuit level reliability prediction. This work proposes a set of compact models of NBTI and CHC effects for analog and mixed-signal circuit, and a direct prediction method which is different from conventional simulation methods. This method is applied in circuit benchmarks and evaluated. This work helps with improving efficiency and accuracy of circuit aging prediction.
ContributorsZheng, Rui (Author) / Cao, Yu (Thesis advisor) / Yu, Hongyu (Committee member) / Bakkaloglu, Bertan (Committee member) / Arizona State University (Publisher)
Created2011
150758-Thumbnail Image.png
Description
Microelectrodes have been used as the neural interface to record brain's neural activities. Most of these electrodes are fixed positioned. Neural signal normally degrades over time due to the body immune response and brain micromotion that move the neurons away from the microelectrode. MEMS technology under SUMMiT VTM processes has

Microelectrodes have been used as the neural interface to record brain's neural activities. Most of these electrodes are fixed positioned. Neural signal normally degrades over time due to the body immune response and brain micromotion that move the neurons away from the microelectrode. MEMS technology under SUMMiT VTM processes has developed miniaturized version of moveable microelectrodes that have the ability to recover the neural signal degradation by searching new cluster of neurons. To move the MEMS microelectrode a combination of four voltage waveforms must be applied to four thermally actuated microactuators. Previous design has used OmneticTM interconnect to transfer the waveforms from the external signal generators to the MEMS device. Unfortunately, the mechanism to attach and detach the OmneticTM interconnect introduce mechanical stress into the brain tissue that often caused raptures in the blood vessel. The goal of this project is to create an integrated System-On-Package Signal Generator that can be implanted on the brain of a rodent. A wireless system and a microcontroller are integrated together with the signal generators. The integrated system can be used to generate a series of voltage waveforms that can be customized to drive an array of MEMS movable microelectrodes when a triggered signal is received wirelessly. 3D stacking technique has been used to develop this Integrated System. 3D stacks lead to several favorable factors, such as (a) reduction in the power consumption of the system, (b) reduction in the overall form-factor of the package, and (c) significant reduction the weight of the package. There are a few challenges that must be overcome in this project, such as a commercially available microcontroller normally have an output voltage of 3.3 V to 5.5 V; however, a voltage of 7 - 8V is required to move the MEMS movable microelectrodes. To acquire higher density neural recording, more number of microelectrodes are needed. In this project, SoP Signal Generator is design to drive independently 3 moveable microelectrodes. Therefore, 12 voltage waveform are required. . However, the use of 12 signal generators is not a workable option since the system will be significantly large. This brings us to the other challenge, the limiting size of the rodent brain. Due to this factor, the SoP Signal Generator has to be deisgned to be able to fit without causing much pressure to the rodent's brain. For the first challenge, which is the limited output voltage of 3.3V on the microcontroller, the RC555 timers are used as an amplifier in addition to generating the signals. Demultiplexers have been for the next challenge, which is the need of 24 waveforms to drive 3 electrodes. For each waveform, 1 demultiplexer is used, making a total of 4 demultiplexers used in the entire system, which is a significant improvement from using 12 signal generators. The last challenge can be approached using 3D system stacking technique as mentioned above. The research aims of this project can be described as follows: (1) the testing and realization of the system part, and the designing of the system in a PCB level, (2) implementing and testing the SoP Signal Generator with the MEMS movable microelectrodes, The final outcome of this project can be used not only for neural applications, but also for more general applications that requires customized signal generations and wireless data transmission.
ContributorsTee, Zikai (Author) / Muthuswamy, Jitendran (Thesis advisor) / Sutanto, Jemmy (Committee member) / Yu, Hongyu (Committee member) / Arizona State University (Publisher)
Created2012
150768-Thumbnail Image.png
Description
There is a tremendous need for wireless biological signals acquisition for the microelectrode-based neural interface to reduce the mechanical impacts introduced by wire-interconnects system. Long wire connections impede the ability to continuously record the neural signal for chronic application from the rodent's brain. Furthermore, connecting and/or disconnecting Omnetics interconnects often

There is a tremendous need for wireless biological signals acquisition for the microelectrode-based neural interface to reduce the mechanical impacts introduced by wire-interconnects system. Long wire connections impede the ability to continuously record the neural signal for chronic application from the rodent's brain. Furthermore, connecting and/or disconnecting Omnetics interconnects often introduces mechanical stress which causes blood vessel to rupture and leads to trauma to the brain tissue. Following the initial implantation trauma, glial tissue formation around the microelectrode and may possibly lead to the microelectrode signal degradation. The aim of this project is to design, develop, and test a compact and power efficient integrated system (IS) that is able to (a) wirelessly transmit triggering signal from the computer to the signal generator which supplies voltage waveforms that move the MEMS microelectrodes, (b) wirelessly transmit neural data from the brain to the external computer, and (c) provide an electrical interface for a closed loop control to continuously move the microelectrode till a proper quality of neural signal is achieved. One of the main challenges of this project is the limited data transmission rate of the commercially available wireless system to transmit 400 kbps of digitized neural signals/electrode, which include spikes, local field potential (LFP), and noise. A commercially available Bluetooth module is only capable to transmit at a total of 115 kbps data transfer rate. The approach to this challenge is to digitize the analog neural signal with a lower accuracy ADC to lower the data rate, so that is reasonable to wirelessly transfer neural data of one channel. In addition, due to the limited space and weight bearing capability to the rodent's head, a compact and power efficient integrated system is needed to reduce the packaged volume and power consumption. 3D SoP technology has been used to stack the PCBs in a 3D form-factor, proper routing designs and techniques are implemented to reduce the electrical routing resistances and the parasitic RC delay. It is expected that this 3D design will reduce the power consumption significantly in comparison to the 2D one. The progress of this project is divided into three different phases, which can be outlined as follow: a) Design, develop, and test Bluetooth wireless system to transmit the triggering signal from the computer to the signal generator. The system is designed for three moveable microelectrodes. b) Design, develop, and test Bluetooth wireless system to wirelessly transmit an amplified (200 gain) neural signal from one single electrode to an external computer. c) Design, develop, and test a closed loop control system that continuously moves a microelectrode in searching of an acceptable quality of neural spikes. The outcome of this project can be used not only for the need of neural application but also for a wider and general applications that requires customized signal generations and wireless data transmission.
ContributorsZhou, Li (Author) / Muthuswamy, Jitendran (Thesis advisor) / Sutanto, Jemmy (Thesis advisor) / Yu, Hongyu (Committee member) / Arizona State University (Publisher)
Created2012
150217-Thumbnail Image.png
Description
The past two decades have been monumental in the advancement of microchips designed for a diverse range of medical applications and bio-analysis. Owing to the remarkable progress in micro-fabrication technology, complex chemical and electro-mechanical features can now be integrated into chip-scale devices for use in biosensing and physiological measurements. Some

The past two decades have been monumental in the advancement of microchips designed for a diverse range of medical applications and bio-analysis. Owing to the remarkable progress in micro-fabrication technology, complex chemical and electro-mechanical features can now be integrated into chip-scale devices for use in biosensing and physiological measurements. Some of these devices have made enormous contributions in the study of complex biochemical processes occurring at the molecular and cellular levels while others overcame the challenges of replicating various functions of human organs as implant systems. This thesis presents test data and analysis of two such systems. First, an ISFET based pH sensor is characterized for its performance in a continuous pH monitoring application. Many of the basic properties of ISFETs including I-V characteristics, pH sensitivity and more importantly, its long term drift behavior have been investigated. A new theory based on frequent switching of electric field across the gate oxide to decrease the rate of current drift has been successfully implemented with the help of an automated data acquisition and switching system. The system was further tested for a range of duty cycles in order to accurately determine the minimum length of time required to fully reset the drift. Second, a microfluidic based vestibular implant system was tested for its underlying characteristics as a light sensor. A computer controlled tilt platform was then implemented to further test its sensitivity to inclinations and thus it‟s more important role as a tilt sensor. The sensor operates through means of optoelectronics and relies on the signals generated from photodiode arrays as a result of light being incident on them. ISFET results show a significant drop in the overall drift and good linear characteristics. The drift was seen to reset at less than an hour. The photodiodes show ideal I-V comparison between photoconductive and photovoltaic modes of operation with maximum responsivity at 400nm and a shunt resistance of 394 MΩ. Additionally, post-processing of the tilt sensor to incorporate the sensing fluids is outlined. Based on several test and fabrication results, a possible method of sealing the open cavity of the chip using a UV curable epoxy has been discussed.
ContributorsMamun, Samiha (Author) / Christen, Jennifer Blain (Thesis advisor) / Goryll, Michael (Committee member) / Yu, Hongyu (Committee member) / Arizona State University (Publisher)
Created2011
150596-Thumbnail Image.png
Description
Advances in miniaturized sensors and wireless technologies have enabled mobile health systems for efficient healthcare. A mobile health system assists the physician to monitor the patient's progress remotely and provide quick feedbacks and suggestions in case of emergencies, which reduces the cost of healthcare without the expense of hospitalization. This

Advances in miniaturized sensors and wireless technologies have enabled mobile health systems for efficient healthcare. A mobile health system assists the physician to monitor the patient's progress remotely and provide quick feedbacks and suggestions in case of emergencies, which reduces the cost of healthcare without the expense of hospitalization. This work involves development of an innovative mobile health system with adaptive biofeedback mechanism and demonstrates the importance of biofeedback in accurate measurements of physiological parameters to facilitate the diagnosis in mobile health systems. Resting Metabolic Rate (RMR) assessment, a key aspect in the treatment of diet related health problems is considered as a model to demonstrate the importance of adaptive biofeedback in mobile health. A breathing biofeedback mechanism has been implemented with digital signal processing techniques for real-time visual and musical guidance to accurately measure the RMR. The effects of adaptive biofeedback with musical and visual guidance were assessed on 22 healthy subjects (12 men, 10 women). Eight RMR measurements were taken for each subject on different days under same conditions. It was observed the subjects unconsciously followed breathing biofeedback, yielding consistent and accurate measurements for the diagnosis. The coefficient of variation of the measured metabolic parameters decreased significantly (p < 0.05) for 20 subjects out of 22 subjects.
ContributorsKrishnan, Ranganath (Author) / Tao, Nongjian (Thesis advisor) / Forzani, Erica (Committee member) / Yu, Hongyu (Committee member) / Arizona State University (Publisher)
Created2012
149395-Thumbnail Image.png
Description
The RADiation sensitive Field Effect Transistor (RADFET) has been conventionally used to measure radiation dose levels. These dose sensors are calibrated in such a way that a shift in threshold voltage, due to a build-up of oxide-trapped charge, can be used to estimate the radiation dose. In order to estimate

The RADiation sensitive Field Effect Transistor (RADFET) has been conventionally used to measure radiation dose levels. These dose sensors are calibrated in such a way that a shift in threshold voltage, due to a build-up of oxide-trapped charge, can be used to estimate the radiation dose. In order to estimate the radiation dose level using RADFET, a wired readout circuit is necessary. Using the same principle of oxide-trapped charge build-up, but by monitoring the change in capacitance instead of threshold voltage, a wireless dose sensor can be developed. This RADiation sensitive CAPacitor (RADCAP) mounted on a resonant patch antenna can then become a wireless dose sensor. From the resonant frequency, the capacitance can be extracted which can be mapped back to estimate the radiation dose level. The capacitor acts as both radiation dose sensor and resonator element in the passive antenna loop. Since the MOS capacitor is used in passive state, characterizing various parameters that affect the radiation sensitivity is essential. Oxide processing technique, choice of insulator material, and thickness of the insulator, critically affect the dose response of the sensor. A thicker oxide improves the radiation sensitivity but reduces the dynamic range of dose levels for which the sensor can be used. The oxide processing scheme primarily determines the interface trap charge and oxide-trapped charge development; controlling this parameter is critical to building a better dose sensor.
ContributorsSrinivasan Gopalan, Madusudanan (Author) / Barnaby, Hugh (Thesis advisor) / Holbert, Keith E. (Committee member) / Yu, Hongyu (Committee member) / Arizona State University (Publisher)
Created2010