Matching Items (25)
Filtering by

Clear all filters

149969-Thumbnail Image.png
Description
In the search for chemical biosensors designed for patient-based physiological applications, non-invasive diagnostic approaches continue to have value. The work described in this thesis builds upon previous breath analysis studies. In particular, it seeks to assess the adsorptive mechanisms active in both acetone and ethanol biosensors designed for

In the search for chemical biosensors designed for patient-based physiological applications, non-invasive diagnostic approaches continue to have value. The work described in this thesis builds upon previous breath analysis studies. In particular, it seeks to assess the adsorptive mechanisms active in both acetone and ethanol biosensors designed for breath analysis. The thermoelectric biosensors under investigation were constructed using a thermopile for transduction and four different materials for biorecognition. The analytes, acetone and ethanol, were evaluated under dry-air and humidified-air conditions. The biosensor response to acetone concentration was found to be both repeatable and linear, while the sensor response to ethanol presence was also found to be repeatable. The different biorecognition materials produced discernible thermoelectric responses that were characteristic for each analyte. The sensor output data is presented in this report. Additionally, the results were evaluated against a mathematical model for further analysis. Ultimately, a thermoelectric biosensor based upon adsorption chemistry was developed and characterized. Additional work is needed to characterize the physicochemical action mechanism.
ContributorsWilson, Kimberly (Author) / Guilbeau, Eric (Thesis advisor) / Pizziconi, Vincent (Thesis advisor) / LaBelle, Jeffrey (Committee member) / Arizona State University (Publisher)
Created2011
133909-Thumbnail Image.png
Description
The field of robotics is rapidly expanding, and with it, the methods of teaching and introducing students must also advance alongside new technologies. There is a challenge in robotics education, especially at high school levels, to expose them to more modern and practical robots. One way to bridge this ga

The field of robotics is rapidly expanding, and with it, the methods of teaching and introducing students must also advance alongside new technologies. There is a challenge in robotics education, especially at high school levels, to expose them to more modern and practical robots. One way to bridge this gap is human-robot interaction for a more hands-on and impactful experience that will leave students more interested in pursuing the field. Our project is a Robotic Head Kit that can be used in an educational setting to teach about its electrical, mechanical, programming, and psychological concepts. We took an existing robot head prototype and further advanced it so it can be easily assembled while still maintaining human complexity. Our research for this project dove into the electronics, mechanics, software, and even psychological barriers present in order to advance the already existing head design. The kit we have developed combines the field of robotics with psychology to create and add more life-like features and functionality to the robot, nicknamed "James Junior." The goal of our Honors Thesis was to initially fix electrical, mechanical, and software problems present. We were then tasked to run tests with high school students to validate our assembly instructions while gathering their observations and feedback about the robot's programmed reactions and emotions. The electrical problems were solved with custom PCBs designed to power and program the existing servo motors on the head. A new set of assembly instructions were written and modifications to the 3D printed parts were made for the kit. In software, existing code was improved to implement a user interface via keypad and joystick to give students control of the robot head they construct themselves. The results of our tests showed that we were not only successful in creating an intuitive robot head kit that could be easily assembled by high school students, but we were also successful in programming human-like expressions that could be emotionally perceived by the students.
ContributorsRathke, Benjamin (Co-author) / Rivera, Gerardo (Co-author) / Sodemann, Angela (Thesis director) / Itagi, Manjunath (Committee member) / Engineering Programs (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2018-05
Description
Volume depletion can lead to migraines, dizziness, and significant decreases in a subject's ability to physically perform. A major cause of volume depletion is dehydration, or loss in fluids due to an imbalance in fluid intake to fluid excretion. Because proper levels of hydration are necessary in order to maintain

Volume depletion can lead to migraines, dizziness, and significant decreases in a subject's ability to physically perform. A major cause of volume depletion is dehydration, or loss in fluids due to an imbalance in fluid intake to fluid excretion. Because proper levels of hydration are necessary in order to maintain both short and long term health, the ability to monitor hydration levels is growing in clinical demand. Although devices capable of monitoring hydration level exist, these devices are expensive, invasive, or inaccurate and do not offer a continuous mode of measurement. The ideal hydration monitor for consumer use needs to be characterized by its portability, affordability, and accuracy. Also, this device would need to be noninvasive and offer continuous hydration monitoring in order to accurately assess fluctuations in hydration data throughout a specified time period. One particular method for hydration monitoring that fits the majority of these criteria is known as bioelectric impedance analysis (BIA). Although current devices using BIA do not provide acceptable levels of accuracy, portability, or continuity in data collection, BIA could potentially be modified to fit many, if not all, desired customer specifications. The analysis presented here assesses the viability of using BIA as a new standard in hydration level measurement. The analysis uses data collected from 22 subjects using an existing device that employs BIA. A regression derived for estimating TBW based on the parameters of age, weight, height, sex, and impedance is presented. Using impedance data collected for each subject, a regression was also derived for estimating impedance based on the factors of age, weight, height, and sex. The derived regression was then used to calculate a new impedance value for each subject, and these new impedance values were used to estimate TBW. Through a paired-t test between the TBW values derived by using the direct measurements versus the calculated measurements of impedance, the two samples were found to be comparable. Considerations for BIA as a noninvasive measurement of hydration are discussed.
ContributorsTenorio, Jorge Antonio (Author) / LaBelle, Jeffrey (Thesis director) / Pizziconi, Vincent (Committee member) / Spano, Mark (Committee member) / Barrett, The Honors College (Contributor) / W. P. Carey School of Business (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
Description
The field of soft robotics is a very quickly growing field that has yet to be fully explored or implemented in all of the possible applications. Soft robotics shows the greatest degree of possibility for mimicking biological systems effectively and accurately. This study seeks to set the groundwork for the

The field of soft robotics is a very quickly growing field that has yet to be fully explored or implemented in all of the possible applications. Soft robotics shows the greatest degree of possibility for mimicking biological systems effectively and accurately. This study seeks to set the groundwork for the development of a biomimetic nautilus using soft robotic methods. The study shows background research and discusses the methods used to develop a nautilus themed sub aquatic robot that uses a double bladder system and a pump to generate thrust for movement. The study shows how the unit would be fabricated and constructed. The study also explores why the second stage of the design failed and how it could potentially be fixed in future iterations.
ContributorsCarlson, Caleb Elijah (Author) / Polygerinos, Panagiotis (Thesis director) / Parsey, John (Committee member) / Engineering Programs (Contributor) / Barrett, The Honors College (Contributor)
Created2017-05
133513-Thumbnail Image.png
Description
The goal of our research was to develop and validate a method for predicting the mechanical behavior of Additively Manufactured multi-material honeycomb structures. Multiple approaches already exist in the field for modeling the behavior of cellular materials, including the bulk property assumption, homogenization and strut level characterization [1]. With the

The goal of our research was to develop and validate a method for predicting the mechanical behavior of Additively Manufactured multi-material honeycomb structures. Multiple approaches already exist in the field for modeling the behavior of cellular materials, including the bulk property assumption, homogenization and strut level characterization [1]. With the bulk property approach, the structure is assumed to behave according to what is known about the material in its bulk formulation, without regard to its geometry or scale. With the homogenization technique, the specimen that is being tested is treated as a solid material within the simulation environment even if the physical specimen is not. Then, reduced mechanical properties are assigned to the specimen to account for any voids that exist within the physical specimen. This approach to mechanical behavior prediction in cellular materials is shape dependent. In other words, the same model cannot be used from one specimen to the next if the cell shapes of those lattices differ in any way. When using the strut level characterization approach, a single strut (the connecting member between nodes constituting a cellular material) is isolated and tested. With this approach, there tends to be a significant deviation in the experimental data due to the small size of the isolated struts. Yet it has the advantage of not being shape sensitive, at least in principle. The method that we developed, and chose to test lies within the latter category, and is what we have coined as the Representative Lattice Element (RLE) Method. This method is modeled after the well-established Representative Volume Element (RVE) method [2]. We define the RLE as the smallest unit over which mechanical tests can be conducted that will provide results which are representative of the larger lattice structure. In other words, the theory is that a single member (or beam in this case) of a honeycomb structure can be taken, tests can be conducted on this member to determine the mechanical properties of the representative lattice element and the results will be representative of the mechanical behavior whole structure. To investigate this theory, we designed specimens, conducted various tensile and compression tests, analyzed the recorded data, conducted a micromechanics study, and performed structural simulation work using commercial Finite Element Analysis software.
ContributorsSalti, Ziyad Zuheir (Co-author) / Eppley, Trevor (Co-author) / Bhate, Dhruv (Thesis director) / Song, Kenan (Committee member) / Engineering Programs (Contributor) / Barrett, The Honors College (Contributor)
Created2018-05
155565-Thumbnail Image.png
Description
The American Diabetes Association reports that diabetes costs $322 billion annually and affects 29.1 million Americans. The high out-of-pocket cost of managing diabetes can lead to noncompliance causing serious and expensive complications. There is a large market potential for a more cost-effective alternative to the current market standard of screen-printed

The American Diabetes Association reports that diabetes costs $322 billion annually and affects 29.1 million Americans. The high out-of-pocket cost of managing diabetes can lead to noncompliance causing serious and expensive complications. There is a large market potential for a more cost-effective alternative to the current market standard of screen-printed self-monitoring blood glucose (SMBG) strips. Additive manufacturing, specifically 3D printing, is a developing field that is growing in popularity and functionality. 3D printers are now being used in a variety of applications from consumer goods to medical devices. Healthcare delivery will change as the availability of 3D printers expands into patient homes, which will create alternative and more cost-effective methods of monitoring and managing diseases, such as diabetes. 3D printing technology could transform this expensive industry. A 3D printed sensor was designed to have similar dimensions and features to the SMBG strips to comply with current manufacturing standards. To make the sensor electrically active, various conductive filaments were tested and the conductive graphene filament was determined to be the best material for the sensor. Experiments were conducted to determine the optimal print settings for printing this filament onto a mylar substrate, the industry standard. The reagents used include a mixture of a ferricyanide redox mediator and flavin adenine dinucleotide dependent glucose dehydrogenase. With these materials, each sensor only costs $0.40 to print and use. Before testing the 3D printed sensor, a suitable design, voltage range, and redox probe concentration were determined. Experiments demonstrated that this novel 3D printed sensor can accurately correlate current output to glucose concentration. It was verified that the sensor can accurately detect glucose levels from 25 mg/dL to 400 mg/dL, with an R2 correlation value as high as 0.97, which was critical as it covered hypoglycemic to hyperglycemic levels. This demonstrated that a 3D-printed sensor was created that had characteristics that are suitable for clinical use. This will allow diabetics to print their own test strips at home at a much lower cost compared to SMBG strips, which will reduce noncompliance due to the high cost of testing. In the future, this technology could be applied to additional biomarkers to measure and monitor other diseases.
ContributorsAdams, Anngela (Author) / LaBelle, Jeffrey (Thesis advisor) / Pizziconi, Vincent (Committee member) / Abbas, James (Committee member) / Arizona State University (Publisher)
Created2017
186267-Thumbnail Image.png
Description
The CNC mill is a highly valuable tool for engineering design, allowing for the creation of precise and complex metal parts. However, due to their high cost, many engineers do not have access to these machines until they enter industry, limiting the knowledge and experience of engineering students. This also

The CNC mill is a highly valuable tool for engineering design, allowing for the creation of precise and complex metal parts. However, due to their high cost, many engineers do not have access to these machines until they enter industry, limiting the knowledge and experience of engineering students. This also restricts the level of engineering design they can participate in as they are limited to lower strength materials and processes. To expand the possibilities for engineering students, hobbyists, and small businesses, we created a reliable and affordable desktop CNC mill. Our machine is capable of cutting non-ferrous metals such as aluminum with 70μm repeatable part precision and be compatible with coolant and vacuum systems.
ContributorsHodson, Kenneth (Author) / Altobelli, Seth (Co-author) / Jordan, Shawn (Thesis director) / Sweeney, Rhett (Committee member) / Barrett, The Honors College (Contributor) / Engineering Programs (Contributor)
Created2023-05
Description

Cornhole, traditionally seen as tailgate entertainment, has rapidly risen in popularity since the launching of the American Cornhole League in 2016. However, it lacks robust quality control over large tournaments, since many of the matches are scored and refereed by the players themselves. In the past, there have been issues

Cornhole, traditionally seen as tailgate entertainment, has rapidly risen in popularity since the launching of the American Cornhole League in 2016. However, it lacks robust quality control over large tournaments, since many of the matches are scored and refereed by the players themselves. In the past, there have been issues where entire competition brackets have had to be scrapped and replayed because scores were not handled correctly. The sport is in need of a supplementary scoring solution that can provide quality control and accuracy over large matches where there aren’t enough referees present to score games. Drawing from the ACL regulations as well as personal experience and testimony from ACL Pro players, a list of requirements was generated for a potential automatic scoring system. Then, a market analysis of existing scoring solutions was done, and it found that there are no solutions on the market that can automatically score a cornhole game. Using the problem requirements and previous attempts to solve the scoring problem, a list of concepts was generated and evaluated against each other to determine which scoring system design should be developed. After determining that the chosen concept was the best way to approach the problem, the problem requirements and cornhole rules were further refined into a set of physical assumptions and constraints about the game itself. This informed the choice, structure, and implementation of the algorithms that score the bags. The prototype concept was tested on their own, and areas of improvement were found. Lastly, based on the results of the tests and what was learned from the engineering process, a roadmap was set out for the future development of the automatic scoring system into a full, market-ready product.

ContributorsGillespie, Reagan (Author) / Sugar, Thomas (Thesis director) / Li, Baoxin (Committee member) / Barrett, The Honors College (Contributor) / Engineering Programs (Contributor) / Dean, W.P. Carey School of Business (Contributor)
Created2023-05
Description

Our project is to create a simplified, portable, modular electrocardiogram known as ECG/EKG. Most medical facilities, including hospitals, clinics, and skilled nursing facilities, still rely on traditional 12-lead EKG equipment consisting of a large cart with long 10 wires. These wires can be a pain to constantly detangle and rearrange

Our project is to create a simplified, portable, modular electrocardiogram known as ECG/EKG. Most medical facilities, including hospitals, clinics, and skilled nursing facilities, still rely on traditional 12-lead EKG equipment consisting of a large cart with long 10 wires. These wires can be a pain to constantly detangle and rearrange to determine a person’s heart conditions. This creates issues in fast paced scenarios such as when a patient is experiencing a heart attack and needs an EKG stat. Additionally, the current technology can be somewhat unreliable at determining heart conditions, causing providers to request multiple EKG’s for patients. With our improved versatile EKG, we can help solve these issues and implement additional outpatient use with its portable features. This can be done by remotely monitoring heart conditions during activities such as exercise, sleep, or stressful events, without worrying about wire disturbance.

ContributorsMullins, Hunter (Author) / Lam, Jadon (Co-author) / Goode, Zachary (Co-author) / Taut, Sarah (Co-author) / Lee, Youngju (Co-author) / Huang, Hai (Co-author) / Byrne, Jared (Thesis director) / Swader, Melissa (Committee member) / McElfish, Alex (Committee member) / Barrett, The Honors College (Contributor) / Engineering Programs (Contributor)
Created2023-05
Description

Our project is to create a simplified, portable, modular electrocardiogram known as ECG/EKG. Most medical facilities, including hospitals, clinics, and skilled nursing facilities, still rely on traditional 12-lead EKG equipment consisting of a large cart with long 10 wires. These wires can be a pain to constantly detangle and rearrange

Our project is to create a simplified, portable, modular electrocardiogram known as ECG/EKG. Most medical facilities, including hospitals, clinics, and skilled nursing facilities, still rely on traditional 12-lead EKG equipment consisting of a large cart with long 10 wires. These wires can be a pain to constantly detangle and rearrange to determine a person’s heart conditions. This creates issues in fast paced scenarios such as when a patient is experiencing a heart attack and needs an EKG stat. Additionally, the current technology can be somewhat unreliable at determining heart conditions, causing providers to request multiple EKG’s for patients. With our improved versatile EKG, we can help solve these issues and implement additional outpatient use with its portable features. This can be done by remotely monitoring heart conditions during activities such as exercise, sleep, or stressful events, without worrying about wire disturbance.

ContributorsGoode, Zachary (Author) / Huang, Hai (Co-author) / Lam, Jadon (Co-author) / Lee, Youngju (Co-author) / Taut, Sarah (Co-author) / Mullins, Hunter (Co-author) / Byrne, Jared (Thesis director) / Swader, Melissa (Committee member) / Barrett, The Honors College (Contributor) / Engineering Programs (Contributor) / School of Manufacturing Systems and Networks (Contributor)
Created2023-05