Matching Items (34)
Filtering by

Clear all filters

133373-Thumbnail Image.png
Description
Many developing countries do not have health care systems that can afford technological biomedical devices or supplies to make such devices operational. To fill this void, nonprofit organizations, like Project C.U.R.E., recondition retired biomedical instrumentation so they can send medical supplies to help these developing countries. One of the issues

Many developing countries do not have health care systems that can afford technological biomedical devices or supplies to make such devices operational. To fill this void, nonprofit organizations, like Project C.U.R.E., recondition retired biomedical instrumentation so they can send medical supplies to help these developing countries. One of the issues with this is that sometimes the devices are unusable because components or expendable supplies are not available (Bhadelia). This issue has also been shown in the Impact Evaluations that Project C.U.R.E. receives from the clinics that explain the reasons why certain devices are no longer in use. That need underlies the idea on which this honors thesis has come into being. The purpose of this honors project was to create packing lists for biomedical instruments that Project C.U.R.E. recycles. This packing list would decrease the likelihood of important items being forgotten when sending devices. If an extra fuse, battery, light bulb, cuff or transducer is the difference between a functional or a nonfunctional medical device, such a list would be of benefit to Project C.U.R.E and these developing countries. In order to make this packing list, manuals for each device were used to determine what supplies were required, what was necessary for cleaning, and what supplies were desirable but functionally optional. This list was then added into a database that could be easily navigated and could help when packing up boxes for a shipment. The database also makes adding and editing the packing list simple and easy so that as Project C.U.R.E. gets more donated devices the packing list can grow.
ContributorsGraft, Kelsey Anne (Author) / Coursen, Jerry (Thesis director) / Walters, Danielle (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2018-05
135668-Thumbnail Image.png
Description
In the medical industry, there have been promising advances in the increase of new types of healthcare to the public. As of 2015, there was a 98% Premarket Approval rate, a 38% increase since 2010. In addition, there were 41 new novel drugs approved for clinical usage in 2014 where

In the medical industry, there have been promising advances in the increase of new types of healthcare to the public. As of 2015, there was a 98% Premarket Approval rate, a 38% increase since 2010. In addition, there were 41 new novel drugs approved for clinical usage in 2014 where the average in the previous years from 2005-2013 was 25. However, the research process towards creating and delivering new healthcare to the public remains remarkably inefficient. It takes on average 15 years, over $900 million by one estimate, for a less than 12% success rate of discovering a novel drug for clinical usage. Medical devices do not fare much better. Between 2005-2009, there were over 700 recalls per year. In addition, it takes at minimum 3.25 years for a 510(k) exempt premarket approval. Plus, a time lag exists where it takes 17 years for only 14% of medical discoveries to be implemented clinically. Coupled with these inefficiencies, government funding for medical research has been decreasing since 2002 (2.5% of Gross Domestic Product) and is predicted to be 1.5% of Gross Domestic Product by 2019. Translational research, the conversion of bench-side discoveries to clinical usage for a simplistic definition, has been on the rise since the 1990s. This may be driving the increased premarket approvals and new novel drug approvals. At the very least, it is worth considering as translational research is directly related towards healthcare practices. In this paper, I propose to improve the outcomes of translational research in order to better deliver advancing healthcare to the public. I suggest Best Value Performance Information Procurement System (BV PIPS) should be adapted in the selection process of translational research projects to fund. BV PIPS has been shown to increase the efficiency and success rate of delivering projects and services. There has been over 17 years of research with $6.3 billion of projects and services delivered showing that BV PIPS has a 98% customer satisfaction, 90% minimized management effort, and utilizes 50% less manpower and effort. Using University of Michigan \u2014 Coulter Foundation Program's funding process as a baseline and standard in the current selection of translational research projects to fund, I offer changes to this process based on BV PIPS that may ameliorate it. As concepts implemented in this process are congruent with literature on successful translational research, it may suggest that this new model for selecting translational research projects to fund will reduce costs, increase efficiency, and increase success. This may then lead to more Premarket Approvals, more new novel drug approvals, quicker delivery time to the market, and lower recalls.
ContributorsDel Rosario, Joseph Paul (Author) / Kashiwagi, Dean (Thesis director) / Kashiwagi, Jacob (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
136798-Thumbnail Image.png
Description
The purpose of this project was to examine the viability of protein biomarkers in pre-symptomatic detection of lung cancer. Regular screening has been shown to vastly improve patient survival outcome. Lung cancer currently has the highest occurrence and mortality of all cancers and so a means of screening would be

The purpose of this project was to examine the viability of protein biomarkers in pre-symptomatic detection of lung cancer. Regular screening has been shown to vastly improve patient survival outcome. Lung cancer currently has the highest occurrence and mortality of all cancers and so a means of screening would be highly beneficial. In this research, the biomarker neuron-specific enolase (Enolase-2, eno2), a marker of small-cell lung cancer, was detected at varying concentrations using electrochemical impedance spectroscopy in order to develop a mathematical model of predicting protein expression based on a measured impedance value at a determined optimum frequency. The extent of protein expression would indicate the possibility of the patient having small-cell lung cancer. The optimum frequency was found to be 459 Hz, and the mathematical model to determine eno2 concentration based on impedance was found to be y = 40.246x + 719.5 with an R2 value of 0.82237. These results suggest that this approach could provide an option for the development of small-cell lung cancer screening utilizing electrochemical technology.
ContributorsEvans, William Ian (Author) / LaBelle, Jeffrey (Thesis director) / Spano, Mark (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
136361-Thumbnail Image.png
Description
Determining the characteristics of an object during a grasping task requires a combination of mechanoreceptors in the muscles and fingertips. The width of a person's finger aperture during the grasp may affect the accuracy of how that person determines hardness, as well. These experiments aim to investigate how an individual

Determining the characteristics of an object during a grasping task requires a combination of mechanoreceptors in the muscles and fingertips. The width of a person's finger aperture during the grasp may affect the accuracy of how that person determines hardness, as well. These experiments aim to investigate how an individual perceives hardness amongst a gradient of varying hardness levels. The trend in the responses is assumed to follow a general psychometric function. This will provide information about subjects' abilities to differentiate between two largely different objects, and their tendencies towards guess-chances upon the presentation of two similar objects. After obtaining this data, it is then important to additionally test varying finger apertures in an object-grasping task. This will allow an insight into the effect of aperture on the obtained psychometric function, thus ultimately providing information about tactile and haptic feedback for further application in neuroprosthetic devices. Three separate experiments were performed in order to test the effect of finger aperture on object hardness differentiation. The first experiment tested a one-finger pressing motion among a hardness gradient of ballistic gelatin cubes. Subjects were asked to compare the hardness of one cube to another, which produced the S-curve that accurately portrayed the psychometric function. The second experiment utilized the Phantom haptic device in a similar setup, using the precision grip grasping motion, instead. This showed a more linear curve; the percentage reported harder increased as the hardness of the second presented cube increased, which was attributed to both the experimental setup limitations and the scale of the general hardness gradient. The third experiment then progressed to test the effect of three finger apertures in the same experimental setup. By providing three separate testing scenarios in the precision grip task, the experiment demonstrated that the level of finger aperture has no significant effect on an individual's ability to perceive hardness.
ContributorsMaestas, Gabrielle Elise (Author) / Helms Tillery, Stephen (Thesis director) / Tanner, Justin (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2015-05
133847-Thumbnail Image.png
Description
With an increased demand for more enzyme-sensitive, bioresorbable and more biodegradable polymers, various studies of copolymers have been developed. Polymers are widely used in various applications of biomedical engineering such as in tissue engineering, drug delivery and wound healing. Depending on the conditions in which polymers are used, they are

With an increased demand for more enzyme-sensitive, bioresorbable and more biodegradable polymers, various studies of copolymers have been developed. Polymers are widely used in various applications of biomedical engineering such as in tissue engineering, drug delivery and wound healing. Depending on the conditions in which polymers are used, they are modified to accommodate a specific need. For instance, polymers used in drug delivery are more efficient if they are biodegradable. This ensures that the delivery system does not remain in the body after releasing the drug. It is therefore crucial that the polymer used in the drug system possess biodegradable properties. Such modification can be done in different ways including the use of peptides to make copolymers that will degrade in the presence of enzymes. In this work, we studied the effect of a polypeptide GAPGLL on the polymer NIPAAm and compare with the previously studied Poly(NIPAAm-co-GAPGLF). Both copolymers Poly(NIPAAm-co-GAPGLL) were first synthesized from Poly(NIPAAm-co-NASI) through nucleophilic substitution by the two peptides. The synthesis of these copolymers was confirmed by 1H NMR spectra and through cloud point measurement, the corresponding LCST was determined. Both copolymers were degraded by collagenase enzyme at 25 ° C and their 1H NMR spectra confirmed this process. Both copolymers were cleaved by collagenase, leading to an increase in solubility which yielded a higher LCST compared to before enzyme degradation. Future studies will focus on evaluating other peptides and also using other techniques such as Differential Scanning Microcalorimetry (DSC) to better observe the LCST behavior. Moreover, enzyme kinetics studies is also crucial to evaluate how fast the enzyme degrades each of the copolymers.
ContributorsUwiringiyimana, Mahoro Marie Chantal (Author) / Vernon, Brent (Thesis director) / Nikkhah, Mehdi (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2018-05
137461-Thumbnail Image.png
Description
A great deal of research has been done on communication barriers between patient and doctor, but due to the complexity of the relationship, little successful solutions have been suggested to bridge interdisciplinary communication between the two persons. This project explores a solution to aid both patient and doctor as they

A great deal of research has been done on communication barriers between patient and doctor, but due to the complexity of the relationship, little successful solutions have been suggested to bridge interdisciplinary communication between the two persons. This project explores a solution to aid both patient and doctor as they seek to communicate with each other regarding the patient's prognosis and treatment with a medical device. By creating a website, the information found therein can be accessed in the doctor's office by using a smartphone or tablet so that both patient and doctor can use it as a resource before, during, and after a doctor's visit. The website, Medical Devices 4 U (MD4U), gives background information on a large selection of medical devices, allows primary sources to share their information with potential consumers of the medical device, permits users to ask questions and comment on other user's comments, and gives a list of questions that a patient can ask a healthcare professional during a doctor's visit. In this report, the nature of doctor and patient communication is exposed and the steps taken to alleviate the communication barriers by way of creating a website are explained.
ContributorsHalls, Sarah Koy (Author) / Spano, Mark (Thesis director) / Garcia, Antonio (Committee member) / Brandon, Tedd (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
137469-Thumbnail Image.png
Description
Oxygen delivery is crucial for the development of healthy, functional tissue. Low tissue oxygenation, or hypoxia, is a characteristic that is common in many tumors. Hypoxia contributes to tumor malignancy and can reduce the success of chemotherapy and radiation treatment. There is a current need to noninvasively measure tumor oxygenation

Oxygen delivery is crucial for the development of healthy, functional tissue. Low tissue oxygenation, or hypoxia, is a characteristic that is common in many tumors. Hypoxia contributes to tumor malignancy and can reduce the success of chemotherapy and radiation treatment. There is a current need to noninvasively measure tumor oxygenation or pO2 in patients to determine a personalized treatment method. This project focuses on creating and characterizing nanoemulsions using a pO2 reporter molecule hexamethyldisiloxane (HMDSO) and its longer chain variants as well as assessing their cytotoxicity. We also explored creating multi-modal (MRI/Fluorescence) nanoemulsions.
ContributorsGrucky, Marian Louise (Author) / Kodibagkar, Vikram (Thesis director) / Rege, Kaushal (Committee member) / Stabenfeldt, Sarah (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
137120-Thumbnail Image.png
Description
Science fiction has a unique ability to express, analyze, and critique concepts in a subtle way that emphasizes a point but is still entertaining to the audience. Because of science fiction's ability to do this it has long been a powerful way to ask questions that would normally not be

Science fiction has a unique ability to express, analyze, and critique concepts in a subtle way that emphasizes a point but is still entertaining to the audience. Because of science fiction's ability to do this it has long been a powerful way to ask questions that would normally not be addressed. As such, this paper provides an overview of the effects of biomedical technology in science fiction films. The discussions in this paper will analyze the different portrayals of the technology in the viewed cinematic pieces and the effects they have on the characters in the film. The discussion will begin with the films that have technology based in Genetic Engineering. This will then be followed by a discussion of the biomedical technology based in the fields of Endocrinology; Reanimation; Preservation; Prosthetics; Physical Metamorphosis; Super-Drugs and Super-Viruses; and Diagnostic, Surgical, and Monitoring Equipment. At the end of this paper movie summaries are provided to assist in clarifying plot details.
ContributorsGrzybowski, Amanda Ann (Author) / Foy, Joseph (Thesis director) / Facinelli, Diane (Committee member) / Barrett, The Honors College (Contributor) / School of Mathematical and Statistical Sciences (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
136869-Thumbnail Image.png
Description
The use of saliva sampling as a noninvasive way for drug analysis as well as the monitoring systems within the body has become increasingly important in recent research. Because of the growing interest in saliva, this project proposes a way to analyze sodium ion concentration in a saliva solution based

The use of saliva sampling as a noninvasive way for drug analysis as well as the monitoring systems within the body has become increasingly important in recent research. Because of the growing interest in saliva, this project proposes a way to analyze sodium ion concentration in a saliva solution based on its fluorescence level when in the presence of a sodium indicator dye and recorded with a smartphone camera. The dyed sample was placed in a specially designed housing to exclude all ambient light from the images. A source light of known wavelength was used to excite the fluorescent dye and the smartphone camera images recorded the emission light wavelengths. After analysis of the images using ImageJ, it was possible to create a model to determine the level of fluorescence based on sodium ion concentration. The smartphone camera image model was compared to readings from a standard fluorescence plate recorder to test the accuracy of the model. The study found that the model was accurate within 5 % as compared to the fluorescence plate recorder. Based on the results, it was concluded that the method and resulting model proposed in this study is a valid was to analyze saliva or other solutions for their sodium ion concentration via images recorded by a smartphone camera.
ContributorsSmith, Catherine Julia (Author) / Antonio, Garcia (Thesis director) / Caplan, Michael (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
134495-Thumbnail Image.png
Description
As the complexity of healthcare continues to rise, the need for change in healthcare delivery is more prominent than ever. One strategy identified by the World Health Organization (WHO) for responding to these increasing complexities is the use of interprofessional practice and education to improve patient outcomes, reduce costs, and

As the complexity of healthcare continues to rise, the need for change in healthcare delivery is more prominent than ever. One strategy identified by the World Health Organization (WHO) for responding to these increasing complexities is the use of interprofessional practice and education to improve patient outcomes, reduce costs, and enhance the patient experience of care (Triple Aim). Interprofessional collaboration among diverse disciplines is evident on the Phoenix Biomedical Campus, integrating a wide variety of institutions and multiple health profession programs; and at the Student Health Outreach for Wellness (SHOW) free clinic, -- a successful tri-university, student-led, faculty mentored, and community-based model of interprofessional learning and care -- based in downtown Phoenix. This project conducted a comparative analysis of interprofessional components of 6 different clinical models in order to provide recommendations for best practice implementation. These models were chosen based on availability of research on interprofessionalism with their clinics. As a result, three recommendations were offered to the SHOW clinic for consideration in their efforts to improve both patient and educational outcomes. Each recommendation was intentionally formulated for its capacity to increase: interprofessionalism and collaboration between multiple disciplines pertaining to healthcare, among healthcare professionals to promote positive patient and educational outcomes. These recommendations include implementing an interprofessional education (IPE) course as a core component in an academic program's curriculum, offering faculty and professional development opportunities for faculty and mentors immersed in the interprofessional clinics, and utilization of simulation centers. Further studies will be needed to evaluate the impact these specific interventions, if adopted, on patient and educational outcomes.
ContributorsMousa, Mohammad (Co-author) / Mousa, Bakir (Co-author) / Johnson, Ross (Co-author) / Harrell, Liz (Thesis director) / Saewert, Karen (Committee member) / Harrington Bioengineering Program (Contributor) / School of Life Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2017-05