Matching Items (2)
Filtering by

Clear all filters

152062-Thumbnail Image.png
Description
Eccentric muscle action (ECC) occurs when the force exerted by a working muscle is less than that of an outside resistance. This is characterized by muscle lengthening, despite actin-myosin crossbridge formation. Research has indicated that muscles acting eccentrically are capable of producing more force when compared to muscles acting concentrically.

Eccentric muscle action (ECC) occurs when the force exerted by a working muscle is less than that of an outside resistance. This is characterized by muscle lengthening, despite actin-myosin crossbridge formation. Research has indicated that muscles acting eccentrically are capable of producing more force when compared to muscles acting concentrically. Further, research has shown ECC muscle actions may have different fatigue patterns that CON actions. The purpose of this study was to determine if a) ECC bench press yields greater strength than concentric (CON) as measured by one-repetition maximum (1RM), b) there is a difference between the number of repetitions that can be completed concentrically and eccentrically under the same relative intensities of 1RM (90%, 80%, 70%, 60%), c) a prediction model may be able to predict ECC 1RM from CON 1RM or CON repetitions to fatigue. For this study, 30 healthy males (age = 24.63 + 5.6 years) were tested for 1RM in CON and ECC bench press, as well as the number of repetitions they were able to complete at various intensities of mode-specific 1RM. A mechanical hoist was affixed to a gantry crane and placed over a standard weightlifting bench. The hoist was connected to 45lb plates that were loaded on a standard barbell, which allowed for mechanical raising and lowering of the barbell. For CON repetitions, the weight was mechanically lowered to the chest and the participant pressed it up. For ECC repetitions, the weight was mechanically raised and the participant lowered it. Paired t-tests showed that ECC 1RM was significantly (p < 0.05) greater than CON 1RM (ECC =255.17 + 68.37lbs, CON = 205.83 + 58.43lbs). There was a significant difference (p < 0.05) between the number of repetitions completed at 90% 1RM (CON = 4.57 + 2.21 repetitions, ECC = 7.67 + 3.24 repetitions). There were no differences in repetitions completed at any other intensity 1RM. CON 1RM and the number of repetitions completed with two different absolute loads (130-150lbs and 155-175lbs) concentrically and eccentrically were valid predictors of ECC 1RM. These data indicate that ECC actions yield increased force capabilities than CON actions, there is no difference in the rate of the fatigue, and ECC 1RM may be predicted from various CON tests.
ContributorsKelly, Stephen B., Jr (Author) / Hooker, Steven (Thesis advisor) / Brown, Lee (Committee member) / Buman, Matthew (Committee member) / Gaesser, Glenn (Committee member) / Swan, Pamela (Committee member) / Arizona State University (Publisher)
Created2013
149587-Thumbnail Image.png
Description
It is broadly accepted that physical activity provides substantial health benefits. Despite strong evidence, approximately 60% to 95% of US adults are insufficiently active to obtain these health benefits. This dissertation explored five projects that examined the measurement properties and methodology for a variety of physical activity assessment methods. Project

It is broadly accepted that physical activity provides substantial health benefits. Despite strong evidence, approximately 60% to 95% of US adults are insufficiently active to obtain these health benefits. This dissertation explored five projects that examined the measurement properties and methodology for a variety of physical activity assessment methods. Project one identified validity evidence for the new MyWellness Key accelerometer in sixteen adults. The MyWellness Key demonstrated acceptable validity evidence when compared to a criterion accelerometer during graded treadmill walking and in free-living settings. This supports the use of the MyWellness Key accelerometer to measure physical activity. Project two evaluated validity (study 1) and test-retest reliability evidence (study 2) of the Global Physical Activity Questionnaire (GPAQ) in a two part study. The GPAQ was compared to direct and indirect criterion measures including object and subjective physical activity instruments. These data provided preliminary validity and reliability evidence for the GPAQ that support its use to assess physical activity. Project three investigated the optimal h.d-1 of accelerometer wear time needed to assess daily physical activity. Using a semi-simulation approach, data from 124 participants were used to compare 10-13 h.d-1 to the criterion 14 h.d-1. This study suggested that a minimum accelerometer wear time of 13 h.d-1 is needed to provide a valid measure of daily physical activity. Project four evaluated validity and reliability evidence of a novel method (Movement and Activity in Physical Space [MAPS] score) that combines accelerometer and GPS data to assess person-environment interactions. Seventy-five healthy adults wore an accelerometer and GPS receiver for three days to provide MAPS scores. This study provided evidence for use of a MAPS score for future research and clinical use. Project five used accelerometer data from 1,000 participants from the 2005-2006 National Health and Nutrition Examination Study. A semi-simulation approach was used to assess the effect of accelerometer wear time (10-14 h.d-1) on physical activity data. These data showed wearing for 12 h.d-1 or less may underestimate time spent in various intensities of physical activity.
ContributorsHerrmann, Stephen (Author) / Ainsworth, Barbara (Thesis advisor) / Gaesser, Glenn (Committee member) / Der Ananian, Cheryl (Committee member) / Kang, Minsoo (Committee member) / Vega-Lopez, Sonia (Committee member) / Arizona State University (Publisher)
Created2011