INTRODUCTION: Exercise performed at moderate to vigorous intensities has been shown to generate a post exercise hypotensive response. Whether this response is observed with very low exercise intensities is unclear. PURPOSE: To compare post physical activity ambulatory blood pressure (ABP) response to a single worksite walking day and a normal

INTRODUCTION: Exercise performed at moderate to vigorous intensities has been shown to generate a post exercise hypotensive response. Whether this response is observed with very low exercise intensities is unclear. PURPOSE: To compare post physical activity ambulatory blood pressure (ABP) response to a single worksite walking day and a normal sedentary work day in pre-hypertensive adults. METHODS: Participants were 7 pre-hypertensive (127 + 8 mmHg / 83 + 8 mmHg) adults (3 male, 4 female, age = 42 + 12 yr) who participated in a randomized, cross-over study that included a control and a walking treatment. Only those who indicated regularly sitting at least 8 hours/day and no structured physical activity were enrolled. Treatment days were randomly assigned and were performed one week apart. Walking treatment consisted of periodically increasing walk time up to 2.5 hours over the course of an 8 hour work day on a walking workstation (Steelcase Company, Grand Rapids, MI). Walk speed was set at 1 mph. Participants wore an ambulatory blood pressure cuff (Oscar 2, SunTech Medical, Morrisville, NC) for 24-hours on both treatment days. Participants maintained normal daily activities on the control day. ABP data collected from 9:00 am until 10:00 pm of the same day were included in statistical analyses. Linear mixed models were used to detect differences in systolic (SBP) and diastolic blood pressure (DBP) by treatment condition over the whole day and post workday for the time periods between 4 -10 pm when participants were no longer at work. RESULTS:BP was significantly lower in response to the walking treatment compared to the control day (Mean SBP 126 +7 mmHg vs.124 +7 mmHg, p=.043; DBP 80 + 3 mmHg vs. 77 + 3 mmHg, p = 0.001 respectively). Post workday (4:00 to 10:00 pm) SBP decreased 3 mmHg (p=.017) and DBP decreased 4 mmHg (p<.001) following walking. CONCLUSION: Even low intensity exercise such as walking on a walking workstation is effective for significantly reducing acute BP when compared to a normal work day.
ContributorsZeigler, Zachary (Author) / Swan, Pamela (Thesis advisor) / Buman, Matthew (Committee member) / Gaesser, Glenn (Committee member) / Arizona State University (Publisher)
Created2013
151846-Thumbnail Image.png
Description
Efficiency of components is an ever increasing area of importance to portable applications, where a finite battery means finite operating time. Higher efficiency devices need to be designed that don't compromise on the performance that the consumer has come to expect. Class D amplifiers deliver on the goal of increased

Efficiency of components is an ever increasing area of importance to portable applications, where a finite battery means finite operating time. Higher efficiency devices need to be designed that don't compromise on the performance that the consumer has come to expect. Class D amplifiers deliver on the goal of increased efficiency, but at the cost of distortion. Class AB amplifiers have low efficiency, but high linearity. By modulating the supply voltage of a Class AB amplifier to make a Class H amplifier, the efficiency can increase while still maintaining the Class AB level of linearity. A 92dB Power Supply Rejection Ratio (PSRR) Class AB amplifier and a Class H amplifier were designed in a 0.24um process for portable audio applications. Using a multiphase buck converter increased the efficiency of the Class H amplifier while still maintaining a fast response time to respond to audio frequencies. The Class H amplifier had an efficiency above the Class AB amplifier by 5-7% from 5-30mW of output power without affecting the total harmonic distortion (THD) at the design specifications. The Class H amplifier design met all design specifications and showed performance comparable to the designed Class AB amplifier across 1kHz-20kHz and 0.01mW-30mW. The Class H design was able to output 30mW into 16Ohms without any increase in THD. This design shows that Class H amplifiers merit more research into their potential for increasing efficiency of audio amplifiers and that even simple designs can give significant increases in efficiency without compromising linearity.
ContributorsPeterson, Cory (Author) / Bakkaloglu, Bertan (Thesis advisor) / Barnaby, Hugh (Committee member) / Kiaei, Sayfe (Committee member) / Arizona State University (Publisher)
Created2013
151246-Thumbnail Image.png
Description
Class D Amplifiers are widely used in portable systems such as mobile phones to achieve high efficiency. The demands of portable electronics for low power consumption to extend battery life and reduce heat dissipation mandate efficient, high-performance audio amplifiers. The high efficiency of Class D amplifiers (CDAs) makes them particularly

Class D Amplifiers are widely used in portable systems such as mobile phones to achieve high efficiency. The demands of portable electronics for low power consumption to extend battery life and reduce heat dissipation mandate efficient, high-performance audio amplifiers. The high efficiency of Class D amplifiers (CDAs) makes them particularly attractive for portable applications. The Digital class D amplifier is an interesting solution to increase the efficiency of embedded systems. However, this solution is not good enough in terms of PWM stage linearity and power supply rejection. An efficient control is needed to correct the error sources in order to get a high fidelity sound quality in the whole audio range of frequencies. A fundamental analysis on various error sources due to non idealities in the power stage have been discussed here with key focus on Power supply perturbations driving the Power stage of a Class D Audio Amplifier. Two types of closed loop Digital Class D architecture for PSRR improvement have been proposed and modeled. Double sided uniform sampling modulation has been used. One of the architecture uses feedback around the power stage and the second architecture uses feedback into digital domain. Simulation & experimental results confirm that the closed loop PSRR & PS-IMD improve by around 30-40 dB and 25 dB respectively.
ContributorsChakraborty, Bijeta (Author) / Bakkaloglu, Bertan (Thesis advisor) / Garrity, Douglas (Committee member) / Ozev, Sule (Committee member) / Arizona State University (Publisher)
Created2012
151220-Thumbnail Image.png
Description
Adverse childhood family environments have been found to have long-term effects on a child's well-being. Although no prior studies have examined the direct effects of childhood family adversities on nighttime blood pressure (BP) dip, parental death and divorce in childhood, have been associated with a variety of related psychological problems

Adverse childhood family environments have been found to have long-term effects on a child's well-being. Although no prior studies have examined the direct effects of childhood family adversities on nighttime blood pressure (BP) dip, parental death and divorce in childhood, have been associated with a variety of related psychological problems in adulthood. The current study examined the direct effects of parental death and divorce in childhood and quality of early family relationships on adult nighttime BP dip as well as the mediating role of three psychosocial factors (depression, hostility and social stress). One hundred and forty-three young adults were asked to complete self-reported measures of the three psychosocial factors and quality of family relationships. Study participants wore an ambulatory blood pressure (ABP) monitor over a 24-hr period in order to assess nocturnal BP dip. Although neither childhood family adversity nor quality of childhood family relationships directly predicted nighttime BP dipping, quality of early family relationships predicted all three psychosocial factors, and hostility was found to mediate the relationship between quality of childhood family relationships and nighttime systolic BP dip. Early family experiences play an important role in influencing nighttime cardiovascular functioning by influencing an individual's psychological functioning in young adulthood. Because nighttime non-dipping has been associated with increased risk for cardiovascular disease and other serious health conditions, the results of the present study have important clinical implications and provide specific psychosocial pathways that may be targeted in future programs designed to prevent and treat cardiovascular disease.
ContributorsTanaka, Rika (Author) / Luecken, Linda J. (Thesis advisor) / Wolchik, Sharlene (Committee member) / Davis, Mary (Committee member) / Arizona State University (Publisher)
Created2012
153818-Thumbnail Image.png
Description
Despite recent strides for awareness, treatment, and control of hypertension, prevalence remains high with estimates suggesting one third of Americans have hypertension. The hypotensive effects of potassium and magnesium have been known and administered in a clinical setting for nearly a century. The purpose of this study was to examine

Despite recent strides for awareness, treatment, and control of hypertension, prevalence remains high with estimates suggesting one third of Americans have hypertension. The hypotensive effects of potassium and magnesium have been known and administered in a clinical setting for nearly a century. The purpose of this study was to examine the effectiveness of taking a potassium/magnesium supplement to help reduce blood pressure in individuals with mildly-moderately elevated blood pressure. In this randomized, controlled crossover trial, potassium and magnesium supplementation was explored among healthy adults with mildly elevated blood pressure in Phoenix, Arizona. Subjects (n = 12) were randomly assigned to ingest either the treatment chewy bar (217 mg potassium/day; 70.8 mg magnesium/day) or a placebo chewy bar for four weeks. For the subsequent four weeks, subjects ingested the other corresponding chewy bar. Systolic (SBP), diastolic (DBP), and average blood pressure values were not significantly different between the two groups (p = 0.645, p = 0.464 and p = 0.939, respectively). Baseline mean blood pressure was 121.0/75.7 mm Hg. The 12 subjects (8 females, 4 males) had a mean age of 29.3 years old and a mean BMI of 26.2. After four weeks, the treatment group had a slightly higher SBP (118.3 ± 13.3 mm Hg) than the control group (116.5 ± 17.8 mm Hg); however, DBP was lower in the treatment group (71.7 ± 12.4 mm Hg) than the control group (73.0 ± 10.0 mm Hg). In conclusion, daily supplementation of potassium and magnesium (217.2 mg/day and 70.8 mg/day, respectively) did not significantly lower blood pressure in adults with mildly-moderately elevated blood pressure.
ContributorsPawloski, Jason (Author) / Johnston, Carol (Thesis advisor) / Vega-Lopez, Sonia (Committee member) / Lespron, Christy (Committee member) / Arizona State University (Publisher)
Created2015
157048-Thumbnail Image.png
Description
Background: Nearly 95% of Americans will develop hypertension, and 67% will not seek treatment. Furthermore, hypertension is the leading risk factor for coronary heart disease. While previous studies have increased the use of blood pressure medication among patients that have received hypertension education, medications may not work for everyone.

Background: Nearly 95% of Americans will develop hypertension, and 67% will not seek treatment. Furthermore, hypertension is the leading risk factor for coronary heart disease. While previous studies have increased the use of blood pressure medication among patients that have received hypertension education, medications may not work for everyone. Due to the life-threatening nature of this condition, it is essential to find an effective alternative for treatment. The purpose of this study was to examine the impact of organometallic complex supplementation on hypertension and left ventricular hypertrophy in 6-week old male Sprague-Dawley rats that were fed either standard rodent chow or a high fat diet for 10 weeks at a university in Arizona.

Methods: Forty-two healthy six-week old male Sprague-Dawley rats were randomly assigned to one of three groups: plain water control, 0.6 mg/ml organometallic complex or 3.0 mg/ml organometallic complex as soon as they arrived. Each rat was then housed individually to prevent the sharing of microbiota through coprophagia. Rats in each treatment group were further divided into two dietary groups that were fed either a high fat diet containing 60% kcal fat that was changed every three days or standard rodent chow. Researchers were not blind to which rat was in each group. At the end of the 10-week study, rats were euthanized with an overdose of sodium pentobarbital (200 mg/kg, i.p.). Heart, left ventricle of the heart, liver, and spleen masses were recorded for each animal. Data were analyzed by two-way ANOVA using SigmaPlot 10.0 software.

Results: At the conclusion of this study, the left ventricle mass of the rats in the high fat diet group were significantly larger than those in the chow group. Neither dose of the organometallic complex supplement prevented these effects induced by high fat feeding.

Conclusion: The organometallic complex supplement was not effective at mitigating the effects of a high fat diet on cardiac hypertrophy in rats. Therefore, this supplement should not be used to treat cardiac hypertrophy.
ContributorsMcCormick, Kelly Ann (Author) / Sweazea, Karen L (Thesis advisor) / Whisner, Corrie M (Committee member) / Alexon, Christy (Committee member) / Arizona State University (Publisher)
Created2019
154094-Thumbnail Image.png
Description
In this thesis, a digital input class D audio amplifier system which has the ability

to reject the power supply noise and nonlinearly of the output stage is presented. The main digital class D feed-forward path is using the fully-digital sigma-delta PWM open loop topology. Feedback loop is used to suppress

In this thesis, a digital input class D audio amplifier system which has the ability

to reject the power supply noise and nonlinearly of the output stage is presented. The main digital class D feed-forward path is using the fully-digital sigma-delta PWM open loop topology. Feedback loop is used to suppress the power supply noise and harmonic distortions. The design is using global foundry 0.18um technology.

Based on simulation, the power supply rejection at 200Hz is about -49dB with

81dB dynamic range and -70dB THD+N. The full scale output power can reach as high as 27mW and still keep minimum -68dB THD+N. The system efficiency at full scale is about 82%.
ContributorsBai, Jing (Author) / Bakkaloglu, Bertan (Thesis advisor) / Arizona State University (Publisher)