Orthogonal horizontal wind vectors were retrieved from the radial velocity using a sector Velocity Azimuth Display method. Streamlines were plotted to determine the potential sites for a correlation of upstream wind speed with wind speed at downstream locations near the wind farm. A "virtual wind turbine" was "placed" in locations along the streamline by using the time-series velocity data at the location as the input to a modeled wind turbine, to determine the extractable energy content at that location. The relationship between this time-dependent energy content upstream and near the wind farm was studied. By correlating the energy content with each upstream location based on a time shift estimated according to advection at the mean wind speed, several fits were evaluated. A prediction of the downstream energy content was produced by shifting the power output in time and applying the best-fit function. This method made predictions of the power near the wind farm several minutes in advance. Predictions were also made up to an hour in advance for a large ramp event. The Magnitude Absolute Error and Standard Deviation are presented for the predictions based on each selected upstream location.
The energy resources and power generation in Kuwait were studied. The characteristics of the residential buildings along with energy codes of practice were investigated and four building archetypes were developed. Moreover, a baseline of end-use electricity consumption and demand was developed. Furthermore, the baseline energy consumption and demand were projected till 2040. It was found that by 2040, energy consumption would double with most of the usage being from AC. While with lighting, there is a negligible increase in consumption due to a projected shift towards more efficient lighting. Peak demand loads are expected to increase by an average growth rate of 2.9% per year. Moreover, the diffusion of different ECMs in the residential sector was modeled through four diffusion scenarios to estimate ECM adoption rates. ECMs’ impact on CO2 emissions and energy consumption of residential buildings in Kuwait was evaluated and the cost of conserved energy (CCE) and annual energy savings for each measure was calculated. AC ECMs exhibited the highest cumulative savings, whereas lighting ECMs showed an immediate energy impact. None of the ECMs in the study were cost effective due to the high subsidy rate (95%), therefore, the impact of ECMs at different subsidy and rebate rates was studied. At 75% subsidized utility price and 40% rebate only on appliances, most of ECMs will be cost effective with high energy savings. Moreover, by imposing charges of $35/ton of CO2, most ECMs will be cost effective.
dependence of wind power potential and turbulence intensity on aerodynamic design of a
special type of building with a nuzzle-like gap at its rooftop. Numerical simulations using
ANSYS Fluent are carried out to quantify the above-mentioned dependency due to three
major geometric parameters of the building: (i) the height of the building, (ii) the depth of
the roof-top gap, and (iii) the width of the roof-top gap. The height of the building is varied
from 8 m to 24 m. Likewise, the gap depth is varied from 3 m to 5 m and the gap width
from 2 m to 4 m. The aim of this entire research is to relate these geometric parameters of
the building to the maximum value and the spatial pattern of wind power potential across
the roof-top gap. These outcomes help guide the design of the roof-top geometry for wind
power applications and determine the ideal position for mounting a micro wind turbine.
From these outcomes, it is suggested that the wind power potential is greatly affected by
the increasing gap width or gap depth. It, however, remains insensitive to the increasing
building height, unlike turbulence intensity which increases with increasing building
height. After performing a set of simulations with varying building geometry to quantify
the wind power potential before the installation of a turbine, another set of simulations is
conducted by installing a static turbine within the roof-top gap. The results from the latter
are used to further adjust the estimate of wind power potential. Recommendations are made
for future applications based on the findings from the numerical simulations.
In this study, primary focus was on optimizing the operating conditions, determining the better catalyst material, and analyzing the reaction products for the process of electrochemical reduction of carbon dioxide (ERC). Membrane electrode assemblies (MEA’s) are developed by air bushing the metal particles with a spray gun on to Nafion-212 which is a solid polymer based electrolyte (SPE), to support the electrodes in the electrochemical reactor gas diffusion layers (GDL) are developed using porous carbon paper. Anode was always made using the same material which is platinum but cathode material was changed as it is the working electrode.
The membrane electrode assembly (MEA) is then placed into the electrochemical reactor along with gas diffusion layer (GDL) to assess the performance of the catalyst material by techniques like linear sweep voltammetry and chronoamperometry. Performance of MEA was analyzed at 4 different potentials, 2 different temperatures and for 2 different cathode catalyst materials. The reaction products of the process are analyzed using gas chromatography (GC) which has thermal conductivity detector (TCD) used for detecting hydrogen (H2), carbon monoxide (CO) and flame ionization detector (FID) used for detecting hydrocarbons. The experiments performed at 40o C gave the better results when compared with the experiments performed at ambient temperature. Also results suggested that copper oxide cathode catalyst has better durability than platinum-carbon. Maximum faradaic efficiency for methane was 5.3% it was obtained at 2.25V using copper oxide catalyst. Furthermore, experiments must be carried out to make the electrochemical reactor more robust to withstand all the operating conditions like higher potentials and to make it a solar powered reactor.
To investigate the impacts of an energy efficiency retrofit, indoor air quality and resident health were evaluated at a low‐income senior housing apartment complex in Phoenix, Arizona, before and after a green energy building renovation. Indoor and outdoor air quality sampling was carried out simultaneously with a questionnaire to characterize personal habits and general health of residents. Measured indoor formaldehyde levels before the building retrofit routinely exceeded reference exposure limits, but in the long‐term follow‐up sampling, indoor formaldehyde decreased for the entire study population by a statistically significant margin. Indoor PM levels were dominated by fine particles and showed a statistically significant decrease in the long‐term follow‐up sampling within certain resident subpopulations (i.e. residents who report smoking and residents who had lived longer at the apartment complex).
Quantifying halogen presence and speciation in particulate matter is crucial given the role atmospheric particulates play in transport and cycling. While some halogens (fluorine and chlorine) are often included in aerosol studies, iodine and bromine have rarely been examined, especially outside of a marine environment. Focus on this environment is, in part, due to the existence of biogenic marine sources for both halogens. However, examining iodine and bromine in an urban environment has the potential to provide key insights into the transport and processing of these species in the atmosphere. As Tempe is set within a desert environment, bromine concentration is expected to be relatively high due to its presence in Earth’s crust, while iodine is expected to exist in higher concentrations near the coast. To detect presence and concentration, ICP-MS analysis was performed on samples taken in Tempe, AZ as well as sites in Bakersfield, CA and Davis, CA, which yielded preliminary results in line with these expectations. A secondary set of samples were taken in Tempe, AZ during dust storms, haboobs, and winter holidays. CIC was used to determine the organic fraction. In doing so, this study aims to identify species present in an urban environment as well as potential transportation pathways.
-see the additional "abstract.pdf" document for formatting
In arid environments like Phoenix, many professional and residential outdoor spaces are cooled by the use of misting systems. These systems spray a fine mist of water droplets that cool down the surrounding air through the endothermic evaporation process. When the water droplets evaporate, they leave behind dissolved material that is present in the water, generating ambient particulate matter (PM). Thus, misting systems are a point source of PM. Currently there is no information on their impact on air quality in close proximity to these systems, or on the chemical composition of the particulate matter generated by the evaporating mist.
In this project, PM concentrations are found to increase on average by a factor of 8 from ambient levels in the vicinity of a residential misting system in controlled experiments. PM concentrations in public places that use misting systems are also investigated. The PM10 concentrations in public places ranged from 0.102 ± 0.010 mg m-3 to 1.47 ± 0.15 mg m-3, and PM2.5 ranged from 0.095 ± 0.010 mg m-3 to 0.99 ± 0.10 mg m-3. Air quality index (AQI) values based on these concentrations indicate that these levels of PM range from unhealthy to hazardous in most cases. PM concentrations tend to decrease after remaining relatively constant with increasing distance from misting systems. Chemical data reveal that chloride and magnesium ions may be used as tracers of aerosolized water from misting systems. The average chloride concentration was 71 µg m-3 in misting samples and below the detection limit for Cl- (< 8.2 µg m-3) in ambient samples. The average magnesium concentration was 11.7 µg m-3 in misting samples and 0.23 µg m-3 in ambient samples.