Matching Items (8)
Filtering by

Clear all filters

Description

Vehicle trips presently account for approximately 50% of San Francisco’s greenhouse gas emissions (San Francisco County Transportation Authority, 2008). City and county officials have developed aggressive strategies for the future of passenger transportation in the metropolitan area, and are determined to move away from a “business as usual” future. This

Vehicle trips presently account for approximately 50% of San Francisco’s greenhouse gas emissions (San Francisco County Transportation Authority, 2008). City and county officials have developed aggressive strategies for the future of passenger transportation in the metropolitan area, and are determined to move away from a “business as usual” future. This project starts with current-state source data from a life-cycle comparison of urban transportation systems (Chester, Horvath, & Madanat, 2010), and carries the inventoried emissions and energy usage through by way of published future scenarios for San Francisco.

From the extrapolated calculations of future emissions/energy, the implied mix of transportation modes can be backed out of the numbers. Five scenarios are evaluated, from “business as usual” through very ambitious “healthy environment” goals. The results show that when planners and policymakers craft specific goals or strategies for a location or government, those targets, even if met, are unlikely to result in the intended physical outcomes. City and state governments would be wise to support broad strategy goals (like 20% GHG reduction) with prioritized specifics that can inform real projects leading to the goals (for instance, add 5 miles of bike path per year through 2020, or remove 5 parking garages and replace them with transit depots). While these results should not be used as predictions or forecasts, they can inform the crafters of future transportation policy as an opportunity for improvement or a cautionary tale.

Created2012-05
Description

The US-Canadian electricity grid is a network of providers and users that operate almost completely independently of one another. In August of 2003, First Energy’s (FE) Harding-Chamberlain transmission line near Akron, Ohio went offline starting a series of cascading failures that eventually led to 8 US states and 1 Canadian

The US-Canadian electricity grid is a network of providers and users that operate almost completely independently of one another. In August of 2003, First Energy’s (FE) Harding-Chamberlain transmission line near Akron, Ohio went offline starting a series of cascading failures that eventually led to 8 US states and 1 Canadian province totaling nearly 50 million people without power. The failure of transmission lines are common occurrences relating to the inability to exactly predict the electricity demand at any time (as will be discussed later in this document). The inability to properly monitor and react across multiple organizations to the downed line was the true failure that led to the blackout. This outage not only left homes and businesses without power but paralyzed critical public services such as transportation networks and hospitals. The estimated cost of the outage is between 4 and 6 billion US dollars.

Description

In recent years, concerns have grown over the risks posed by climate change on the U.S. electricity grid. The availability of water resources is integral to the production of electric power, and droughts are expected to become more frequent, severe, and longer-lasting over the course of the twenty-first century. The

In recent years, concerns have grown over the risks posed by climate change on the U.S. electricity grid. The availability of water resources is integral to the production of electric power, and droughts are expected to become more frequent, severe, and longer-lasting over the course of the twenty-first century. The American Southwest, in particular, is expected to experience large deficits in streamflow. Studies on the Colorado River anticipate streamflow declines of 20-45% by 2050. Other climactic shifts—such as higher water and air temperatures—may also adversely affect power generation. As extreme weather becomes more common, better methods are needed to assess the impact of climate change on power generation. This study uses a physically-based modeling system to assess the vulnerability of power infrastructure in the Southwestern United States at a policy-relevant scale.

Thermoelectric power—which satisfies a majority of U.S. electricity demand—is vulnerable to drought. Thermoelectric power represents the backbone of the U.S. power sector, accounting for roughly 91% of generation. Thermoelectric power also accounts for roughly 39% of all water withdrawals in the U.S.—roughly equivalent to the amount of water used for agriculture. Water use in power plants is primarily dictated by the needs of the cooling system. During the power generation process, thermoelectric power plants build up waste heat, which must be discharged in order for the generation process to continue. Traditionally, water is used for this purpose, because it is safe, plentiful, and can absorb a large amount of heat. However, when water availability is constrained, power generation may also be adversely affected. Thermoelectric power plants are particularly susceptible to changes in streamflow and water temperature. These vulnerabilities are exacerbated by environmental regulations, which govern both the amount of water withdrawn, and the temperatures of the water discharged. In 2003, extreme drought and heat impaired the generating capacity of more than 30 European nuclear power plants, which were unable to comply with environmental regulations governing discharge temperatures. Similarly, many large base-load thermoelectric facilities in the Southeastern United States were threatened by a prolonged drought in 2007 and 2008. During this period, the Tennessee Valley Authority (TVA) reduced generation at several facilities, and one major facility was shut down entirely. To meet demand, the TVA was forced to purchase electricity from the grid, causing electricity prices to rise.

Although thermoelectric power plants currently produce most of the electric power consumed in the United States, other sources of power are also vulnerable to changes in climate. Renewables are largely dependent on natural resources like rain, wind, and sunlight. As the quantity and distribution of these resources begins to change, renewable generation is also likely to be affected. Hydroelectric dams represent the largest source of renewable energy currently in use throughout the United States. Under drought conditions, when streamflow attenuates and reservoir levels drop, hydroelectric plants are unable to operate at normal capacity. In 2001, severe drought in California and the Pacific Northwest restricted hydroelectric power generation, causing a steep increase in electricity prices. Although blackouts and brownouts were largely avoided, the Northwest Power and Conservation Council estimated a regional economic impact of roughly $2.5 to $6 billion. In addition to hydroelectric power, it has also been theorized that solar energy resources may also be susceptible to predicted increases in surface temperature and atmospheric albedo. One study predicts that solar facilities in the Southwestern U.S. may suffer losses of 2-5%.

The aim of this study is to estimate the extent to which climate change may impact power generation in the Southwestern United States. This analysis will focus on the Western Interconnection, which comprises the states of Washington, Oregon, California, Idaho, Nevada, Utah, Arizona, Colorado, Wyoming, Montana, South Dakota, New Mexico and Texas. First, climactic and hydrologic parameters relevant to power generation are identified for five types of generation technologies. A series of functional relationships are developed such that impacts to power generation can be estimated directly from changes in certain meteorological and hydrological parameters. Next, climate forcings from the CMIP3 multi-model ensemble are used as inputs to a physically-based modeling system (consisting of a hydrological model, an offline routing model, and a one-dimensional stream temperature model). The modeling system is used to estimate changes in climactic and hydrologic parameters relevant to electricity generation for various generation technologies. Climactic and hydrologic parameters are then combined with the functional relationships developed in the first step to estimate impacts to power generation over the twenty-first century.

Description

This LCA used data from a previous LCA done by Chester and Horvath (2012) on the proposed California High Speed Rail, and furthered the LCA to look into potential changes that can be made to the proposed CAHSR to be more resilient to climate change. This LCA focused on the

This LCA used data from a previous LCA done by Chester and Horvath (2012) on the proposed California High Speed Rail, and furthered the LCA to look into potential changes that can be made to the proposed CAHSR to be more resilient to climate change. This LCA focused on the energy, cost, and GHG emissions associated with raising the track, adding fly ash to the concrete mixture in place of a percentage of cement, and running the HSR on solar electricity rather than the current electricity mix. Data was collected from a variety of sources including other LCAs, research studies, feasibility studies, and project information from companies, agencies, and researchers in order to determine what the cost, energy requirements, and associated GHG emissions would be for each of these changes. This data was then used to calculate results of cost, energy, and GHG emissions for the three different changes. The results show that the greatest source of cost is the raised track (Design/Construction Phase), and the greatest source of GHG emissions is the concrete (also Design/Construction Phase).

Created2014-06-13
Description

The ultimate goal of this LCA is to give Arizona State University specific advice on possible changes in lighting systems that will reduce environmental impacts and support ASU’s sustainability efforts. The aim is to assess the potential for a decrease in specific environmental impacts (CO2 emissions and energy use) and

The ultimate goal of this LCA is to give Arizona State University specific advice on possible changes in lighting systems that will reduce environmental impacts and support ASU’s sustainability efforts. The aim is to assess the potential for a decrease in specific environmental impacts (CO2 emissions and energy use) and economic impact (cost) from changing to a different type of lighting in a prototypical classroom in Wrigley Hall. The scope of this assessment is to analyze the impacts of T8 lamps lasting 50,000 hours. Thus, a functional unit was defined as 50,000 hours of use, maintaining roughly 825 lumens. To put this in perspective, 50,000 hours is equivalent to 8 hours of use per day, 365 days per year, for approximately 17.1 years.

Created2014-06-13
Description

Building energy assessment often focuses on the use of electricity and natural gas during the use phase of a structure while ignoring the energy investments necessary to construct the facility. This research develops a methodology for quantifying the “embedded” energy and greenhouse gases (GHG) in the building infrastructure of an

Building energy assessment often focuses on the use of electricity and natural gas during the use phase of a structure while ignoring the energy investments necessary to construct the facility. This research develops a methodology for quantifying the “embedded” energy and greenhouse gases (GHG) in the building infrastructure of an entire metropolitan region. “Embedded” energy and GHGs refer to the energy necessary to manufacture materials and construct the infrastructure. Using these methods, a case study is developed for Los Angeles County.

158-Thumbnail Image.jpg
Description

Sustainable mobility policy for long-distance transportation services should consider emerging automobiles and aircraft as well as infrastructure and supply chain life-cycle effects in the assessment of new high-speed rail systems. Using the California corridor, future automobiles, high-speed rail and aircraft long-distance travel are evaluated, considering emerging fuel-efficient vehicles, new train

Sustainable mobility policy for long-distance transportation services should consider emerging automobiles and aircraft as well as infrastructure and supply chain life-cycle effects in the assessment of new high-speed rail systems. Using the California corridor, future automobiles, high-speed rail and aircraft long-distance travel are evaluated, considering emerging fuel-efficient vehicles, new train designs and the possibility that the region will meet renewable electricity goals. An attributional per passenger-kilometer-traveled life-cycle inventory is first developed including vehicle, infrastructure and energy production components. A consequential life-cycle impact assessment is then established to evaluate existing infrastructure expansion against the construction of a new high-speed rail system. The results show that when using the life-cycle assessment framework, greenhouse gas footprints increase significantly and human health and environmental damage potentials may be dominated by indirect and supply chain components. The environmental payback is most sensitive to the number of automobile trips shifted to high-speed rail, and for greenhouse gases is likely to occur in 20–30 years. A high-speed rail system that is deployed with state-of-the-art trains, electricity that has met renewable goals, and in a configuration that endorses high ridership will provide significant environmental benefits over existing modes. Opportunities exist for reducing the long-distance transportation footprint by incentivizing large automobile trip shifts, meeting clean electricity goals and reducing material production effects.

Created2012-03-16
Description

This report updates Supplementary Information section 2.1.2.2 (Recirculating Cooling) of Bartos and Chester (2015). Extraneous derivations have been removed and an error corrected.

Impacts of Climate Change on Electric Power Supply in the Western U.S., Matthew Bartos and Mikhail Chester, Nature Climate Change, 2015, 4(8), pp. 748-752, DOI: 10.1038
climate2648.