Matching Items (1)
158167-Thumbnail Image.png
Description
Presented in this thesis are two projects that fall under the umbrella of magnetically actuated electronics and robotics for medical applications. First, magnetically actuated tunable soft electronics are discussed in Chapter 2. Wearable and implantable soft electronics are clinically available and commonplace. However, these devices can be taken a ste

Presented in this thesis are two projects that fall under the umbrella of magnetically actuated electronics and robotics for medical applications. First, magnetically actuated tunable soft electronics are discussed in Chapter 2. Wearable and implantable soft electronics are clinically available and commonplace. However, these devices can be taken a step further to improve the lives of their users by adding remote tunability. The four electric units tested were planar inductors, axial inductors, capacitors and resistors. The devices were made of polydimethylsiloxane (PDMS) for flexibility with copper components for conductivity. The units were tuned using magnets and mobile components comprised of iron filings and ferrofluid. The characteristic properties examined for each unit are as follows: inductance and quality factor (Q-factor) for inductors, capacitance and Q-factor for capacitors, and impedance for resistors. There were two groups of tuning tests: quantity effect and position effect of the mobile component. The position of the mobile component had a larger effect on each unit, with 20-23% change in inductance for inductors (from 3.31 µH for planar and 0.44 µH for axial), 12.7% from 2.854 pF for capacitors and 185.3% from 0.353 kΩ for resistors.

Chapter 3 discusses a magnetic needle tracking device with operative assistance from a six degree-of-freedom robotic arm. Traditional needle steering faces many obstacles such as torsional effects, buckling, and small radii of curvature. To improve upon the concept, this project uses permanent magnets in parallel with a tracking system to steer and determine the position and orientation of the needle in real time. The magnet configuration is located at the end effector of the robotic arm. The trajectory of the end effector depends on the needle’s path, and vice versa. The distance the needle travels inside the workspace is tracked by a direct current (DC) motor, to which the needle is tethered. Combining this length with the pose of the end effector, the position and orientation of the needle can be calculated. Simulation of this tracking device has shown the functionality of the system. Testing has been done to confirm that a single magnet pulls the needle through the phantom tissue.
ContributorsEdwards, Dakota (Author) / Marvi, Hamidreza (Thesis advisor) / Lee, Hyunglae (Committee member) / Berman, Spring (Committee member) / Arizona State University (Publisher)
Created2020