Matching Items (2)
Filtering by

Clear all filters

156917-Thumbnail Image.png
Description
Radioactive cesium (137Cs), released from nuclear power plants and nuclear accidental releases, is a problem due to difficulties regarding its removal. Efforts have been focused on removing cesium and the remediation of the contaminated environment. Traditional treatment techniques include Prussian blue and nano zero-valent ion (nZVI) and nano-Fe/Cu particles to

Radioactive cesium (137Cs), released from nuclear power plants and nuclear accidental releases, is a problem due to difficulties regarding its removal. Efforts have been focused on removing cesium and the remediation of the contaminated environment. Traditional treatment techniques include Prussian blue and nano zero-valent ion (nZVI) and nano-Fe/Cu particles to remove Cs from water; however, they are not efficient at removing Cs when present at low concentrations of about 10 parts-per-billion (ppb), typical of concentrations found in the radioactive contaminated sites.

The objective of this study was to develop an innovative and simple method to remove Cs+ present at low concentrations by engineering a proteoliposome transporter composed of an uptake protein reconstituted into a liposome vesicle. To achieve this, the uptake protein, Kup, from E. coli, was isolated through protein extraction and purification procedures. The new and simple extraction methodology developed in this study was highly efficient and resulted in purified Kup at ~1 mg/mL. A new method was also developed to insert purified Kup protein into the bilayers of liposome vesicles. Finally, removal of CsCl (10 and 100 ppb) was demonstrated by spiking the constructed proteoliposome in lab-fortified water, followed by incubation and ultracentrifugation, and measuring Cs+ with inductively coupled plasma mass spectrometry (ICP-MS).

The ICP-MS results from testing water contaminated with 100 ppb CsCl, revealed that adding 0.1 – 8 mL of Kup proteoliposome resulted in 0.29 – 12.7% Cs removal. Addition of 0.1 – 2 mL of proteoliposome to water contaminated with 10 ppb CsCl resulted in 0.65 – 3.43% Cs removal. These removal efficiencies were greater than the control, liposome with no protein.

A linear relationship was observed between the amount of proteoliposome added to the contaminated water and removal percentage. Consequently, by adding more volumes of proteoliposome, removal can be simply improved. This suggests that with ~ 60-70 mL of proteoliposome, removal of about 90% can be achieved. The novel technique developed herein is a contribution to emerging technologies in the water and wastewater treatment industry.
ContributorsHakim Elahi, Sepideh (Author) / Conroy-Ben, Otakuye (Thesis advisor) / Abbaszadegan, Morteza (Committee member) / Fox, Peter (Committee member) / Arizona State University (Publisher)
Created2018
155866-Thumbnail Image.png
Description
Activated Carbon has been used for decades to remove organics from water at large scale in municipal water treatment as well as at small scale in Point of Use (POU) and Point of Entry (POE) water treatment. This study focused on Granular Activated Carbon (GAC) and also activated Carbon Block

Activated Carbon has been used for decades to remove organics from water at large scale in municipal water treatment as well as at small scale in Point of Use (POU) and Point of Entry (POE) water treatment. This study focused on Granular Activated Carbon (GAC) and also activated Carbon Block (CB) were studied.

This thesis has three related elements for organics control in drinking water. First, coagulation chemistry for Alum and Aluminum Chlorohydrate (ACH) was optimized for significant organics removal to address membrane fouling issue at a local municipal water treatment plant in Arizona. Second, Rapid Small Scale Column Tests were conducted for removal of Perfluorinated compounds (PFC), PFC were present in groundwater at a local site in Arizona at trace levels with combined concentration of Perfluorooctaneoic Acid (PFOA) and Perfloorooctanesulfonic Acid (PFOS) up to 245 ng/L. Groundwater from the concerned site is used as drinking water source by a private utility. PFC Removal was evaluated for different GAC, influent concentrations and particle sizes. Third, a new testing protocol (Mini Carbon Block (MCB)) for bench scale study of POU water treatment device, specifically carbon block filter was developed and evaluated. The new bench scale decreased the hydraulic requirements by 60 times approximately, which increases the feasibility to test POU at a lab scale. It was evaluated for a common POU organic contaminant: Chloroform, and other model contaminants.

10 mg/L of ACH and 30 mg/L of Alum with pH adjustment were determined as optimal coagulant doses. Bituminous coal based GAC was almost three times better than coconut shell based GAC for removing PFC. Multiple tests with MCB suggested no short circuiting and consistent performance for methylene blue though chloroform removal tests underestimated full scale carbon block performance but all these tests creates a good theoretical and practical fundament for this new approach and provides directions for future researchers.
ContributorsAshani, Harsh Satishbhai (Author) / Westerhoff, Paul (Thesis advisor) / Hristovski, Kiril (Committee member) / Conroy-Ben, Otakuye (Committee member) / Arizona State University (Publisher)
Created2017